Floor in front of and under the fireplace
Floors made from combustible materials, such as carpets, parquet floors or cork is
to be protected by a shield of non-combustible material for example ceramics,
stone, glass or steel placed under the fireplace so that it should reach out to
50 cm in front and 30 cm besides.

2.4 Connection of the fireplace

The connection for attaching to the chimney must be able to withstand at least
400°C.
PLEASE NOTE:
Before connecting the stove the local authority responsible for approving
heating systems must be consulted!
Connection pieces must be firmly connected to the stove and to each other and
must not leak. They must not project into the open diameter of the chimney. The
connection piece between the stove and the chimney must have the same diameter
as the pipe socket on the stove. Horizontal connection pieces of over 0.5 m must
rise towards the chimney at an angle of 10 degrees. Any pipes which are not heat
insulated or vertical must not be longer than 1 metre.
The requirements of the Fire Regulations (FeuVO) apply, as well
as local building regulations such as for the chimney standards
DIN 18896, DIN 4705, EN 13384, DIN 18160 and EN 15287.
Connection pieces must be tested to EN 1856-2. Measurement
X (distance from flammable construction and other materials)
must be as defined by the manufacturer of the connection piece.
PLEASE NOTE:
Fitting to a chimney with a functional height of less than 4 m, or
if several stoves are being fitted, less than 5 m, is not permitted.
(See: Data for chimney calculations / Chapter 3.) A maximum of
two other fires can be connected to the chimney to be connected to the stove.
For safety reasons it is not permitted to use a steam extractor hood to remove air
when the stove is producing heat.
The fireplace can usually be
connected to the chimney with an
angle pipe
With weak chimney draught, the
fireplace is to be connected to
the chimney through a vertical
flue gas pipe facilitating dis-
charge.
X

Manual

View the manual for the Wamsler Panoramic here, for free. This manual comes under the category heaters and has been rated by 3 people with an average of a 9.1. This manual is available in the following languages: English. Do you have a question about the Wamsler Panoramic or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Wamsler and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Wamsler Panoramic specifications

Below you will find the product specifications and the manual specifications of the Wamsler Panoramic.

General
BrandWamsler
ModelPanoramic
Productheater
LanguageEnglish
FiletypeUser manual (PDF)

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Wamsler Panoramic below.

What is the ideal room temperature?

Most people find that the ideal room temperature is between 19 and 22 degrees Celsius.

Is the manual of the Wamsler Panoramic available in English?

Yes, the manual of the Wamsler Panoramic is available in English .

Is your question not listed? Ask your question here

No results