View the manual for the UPM ET420C here, for free. This manual comes under the category switches and has been rated by 1 people with an average of a 6.9. This manual is available in the following languages: English. Do you have a question about the UPM ET420C or do you need help? Ask your question here
Below you will find the product specifications and the manual specifications of the UPM ET420C.
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the UPM ET420C below.
To troubleshoot the flashing for short random feature of the UPM ET420C switch, follow these steps: 1. Press the "SET" button on the switch to enter the settings mode. 2. Use the "RND" button to select the "RANDOM FUNCTION" option. 3. Press the "SET" button to confirm the selection. 4. Use the "RND" button to choose the "Short random" option. 5. Press the "SET" button to activate the short random flashing. 6. The switch will now randomly turn on and off for a duration of 1-2 hours. 7. If the flashing is not working, check that the switch is properly connected to the power source. 8. Ensure that the switch is not in manual on/off mode, as this may override the random function. 9. If the issue persists, try resetting the switch by pressing the "R" button. 10. If none of the troubleshooting steps resolve the issue, refer to the manual for further assistance. By following these steps, you can troubleshoot the flashing for short random feature of the UPM ET420C switch.
To troubleshoot the flashing for long random feature of the UPM ET420C switch, follow these steps: 1. Check that the switch is properly connected to the power source and that there is power supply. 2. Ensure that the switch is not in manual on/off mode, as this may override the random function. Press the "ON/OFF" button to ensure it is in automatic mode. 3. Verify that the random function is enabled. Press the "RND" button to activate the random function. 4. Make sure that the switch is set to the "Long random" option. Press the "RND" button to select the "Long random" option. 5. Check if the switch is programmed with the desired random time. Press the "SET" button and use the "RND" button to select program 20. Set the desired random time using the "SET" button. 6. If the issue persists, try resetting the switch by pressing the "R" button. 7. If none of the troubleshooting steps resolve the issue, refer to the manual for further assistance. By following these steps, you can troubleshoot the flashing for long random feature of the UPM ET420C switch.
To troubleshoot the ET420C electronic outdoor timer if it is not functioning properly, follow these steps: 1. Check if the LCD display seems frozen or unresponsive. If so, press the reset button to reset the timer. 2. If the LCD display seems dim or faded, the timer may be exposed to extreme cold temperatures. Bring the timer indoors to room temperature and wait for several minutes for the display to return to normal. 3. Ensure that the program disable feature is not enabled, as this may prevent the programmed ON/OFF times from executing. Press the SET button three times to exit the disable mode. 4. Verify that the random function is not enabled, as this may affect the timer's operation. Press the ON/OFF button to disable the random function. 5. If the issue persists, refer to the manual for further troubleshooting steps. By following these steps, you can troubleshoot the ET420C electronic outdoor timer if it is not functioning properly.
To troubleshoot the UPM ET420C switch if it is not responding to the daylight control using photocell, follow these steps: 1. Check if the photocell is obstructed or covered. Ensure that there are no objects blocking the photocell's view of the ambient light. 2. Verify that the photocell sensitivity is set correctly. Press the SET button and navigate to the daylight control mode. Adjust the photocell sensitivity using the appropriate button. 3. Ensure that the switch is in the correct daylight control mode. Choose the desired mode based on your preference for the switch to be on or off in different light conditions. 4. Check if the switch is in manual on/off mode. Press the ON/OFF button to ensure that the switch is in automatic mode. 5. If the issue persists, try resetting the switch by pressing the reset button. 6. If none of the troubleshooting steps resolve the issue, refer to the manual for further assistance. By following these steps, you can troubleshoot the UPM ET420C switch if it is not responding to the daylight control using photocell.
To troubleshoot if the clock setting of the UPM ET420C switch is not accurate, follow these steps: 1. Check if the switch is set to the correct time zone. Press the SET button and navigate to the clock setting mode. Use the appropriate buttons to adjust the time zone. 2. Verify that the switch is set to the correct date and time. Press the SET button and navigate to the clock setting mode. Use the appropriate buttons to adjust the date and time. 3. Ensure that the switch is not in manual mode, as this may override the clock setting. Press the ON/OFF button to ensure that the switch is in automatic mode. 4. Check if the switch has a weak or fading LCD display. If so, bring the switch indoors to room temperature and wait for several minutes for the display to return to normal. 5. If the issue persists, try resetting the switch by pressing the reset button. 6. If none of the troubleshooting steps resolve the issue, refer to the manual for further assistance. By following these steps, you can troubleshoot if the clock setting of the UPM ET420C switch is not accurate.
Yes, the manual of the UPM ET420C is available in English .
Is your question not listed? Ask your question here
No results
Need help?
Do you have a question about the UPM and is the answer not in the manual?
Question and answer
Number of questions: 0