It is possible to move between the menu items using the PREVIOUS and NEXT buttons. Use + and – to change the
typed value. It is necessary to confirm the typed value in the menu with the CONFIRM button. Press the button for
LEAVING MENU to leave the menu and terminate typing.
The adjusted value flashes on the display.
Some items of user menu are displayed conditionally – depending on setting of other items.
User menu items
Group 1 Parameters of equithermal regulation
Equithermal regulation states the required value of the temperature of the heating water depending on the ambient
temperature. The selection of parameters for the calculation depends on the status of binary input NU.
For NM (NU) disconnected, it is valid:
Engaged value of the temperature of heating water = (20 – Outdoor temperature) * EQUITHERM
CONSTANT 1 + 20 + EQUITHERM CONSTANT 2
For NM (NU) connected, it is valid:
Engaged value of the temperature of heating water = (20 – Outdoor temperature) * EQUITHERM
CONSTANT 3 + 20 + EQUITHERM CONSTANT 4
The required value of the temperature of the output water is restricted concerning the range stated by the items
HEATING WATER SETTING –LOWER LIMIT and HEATING WATER LIMIT –UPPER LIMIT of
service menu.
The equitherm regulation requires the connection of an external sensor for the temperature of the service water; the
heating must be set for OTC.
The equitherm regulation parameters are displayed in the user menu only in the case where the heating regime is
set for OTC.
OTC CONSTANT 1
CURVE SLOPE
Parameter of equitherm regulation, declination of the curve. Valid for NM (NU) disconnected.
The range of setting 0.1 .. 6.0, step 0,1, initial value 1.6.
OTC CONSTANT 2
CURVE SHIFT [°C]
Parameter of equitherm regulation, shift of the curve. Valid for NM (NU) disconnected.
The range of setting is -20°C .. +40°C, step 1°C, initial value 0.
OTC CONSTANT 3
CURVE SLOPE
Parameter of equitherm regulation, declination of the curve. Valid for NM (NU) connected.
The range of setting is 0.1 .. 6.0, step 0,1, initial value 1.6.
OTC CONSTANT 4
CURVE SHIFT [°C]
Parameter of equitherm regulation, shift of the curve. Valid for NM (NU) connected.
The range of setting is -20°C .. +40°C, step 1°C, initial value -5.
Manual
View the manual for the Thermona THERM EL 15 here, for free. This manual comes under the category water heaters & boilers and has been rated by 1 people with an average of a 8.3. This manual is available in the following languages: English. Do you have a question about the Thermona THERM EL 15 or do you need help? Ask your question here