View the manual for the Tesy Compact 10 here, for free. This manual comes under the category water heaters & boilers and has been rated by 1 people with an average of a 7.7. This manual is available in the following languages: English. Do you have a question about the Tesy Compact 10 or do you need help? Ask your question here

The Tesy Compact 10 is a water heater and boiler that can be placed either horizontally or vertically, offering flexibility in its installation. It operates using a tank system for water storage, allowing for consistent hot water availability. The maximum warm-up time for this unit is 20 minutes, ensuring quick access to hot water whenever needed. With a maximum power of 1500 W, this electric water heater and boiler has an adjustable thermostat, allowing users to easily control the temperature according to their preferences. Its fuel type is electric, eliminating the need for other energy sources such as gas. The Tesy Compact 10 has an energy efficiency scale ranging from A+ to F, with its energy efficiency class classified as B. This indicates its moderately efficient use of energy, helping to reduce overall energy consumption and costs. Its annual energy consumption is estimated to be 573 kWh, providing an indication of its electricity usage. In terms of noise level, this water heater and boiler operates at a mere 15 dB, ensuring a quiet environment when in use. However, it does not support solar batteries, meaning it is unable to utilize solar energy as an alternative power source. Constructed with quality materials, the Tesy Compact 10 is designed to be reliable and durable over time. As an electric water heater and boiler, it offers convenience and comfort for households by providing efficient hot water supply.

| Brand | Tesy |
| Model | Compact 10 | GCU 1015 L52 RC |
| Product | water heater & boiler |
| EAN | 3800879123445 |
| Language | English |
| Filetype | User manual (PDF), Energy label (PDF) |
| Placement supported | Horizontal/Vertical |
| Type | Tank (water storage) |
| Boiler system | - |
| Heater location | - |
| Product color | Grey, White |
| Fuel type | Electric |
| Solar batteries support | No |
| Water tank capacity | 10 L |
| Warm-up time (max) | 20 min |
| Maximum power | 1500 W |
| Domestic Hot Water (DHW) flow | - l/min |
| Adjustable thermostat | Yes |
| Noise level | 15 dB |
| Annual energy consumption | 573 kWh |
| Energy efficiency scale | A+ to F |
| Energy efficiency class | B |
| LED indicators | Yes |
| Width | 377 mm |
| Depth | 247 mm |
| Height | 399 mm |
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Tesy Compact 10 below.
Most people find that the ideal room temperature is between 19 and 22 degrees Celsius.
The Tesy Compact 10 has a height of 399 mm.
The Tesy Compact 10 has a width of 377 mm.
The Tesy Compact 10 has a depth of 247 mm.
The Tesy Compact 10 has energy label B.
Yes, the Tesy Compact 10 supports both horizontal and vertical placement, providing flexibility in installation options for the user.
Yes, the Tesy Compact 10 features an adjustable thermostat, allowing users to control the desired water temperature based on their preferences or specific needs.
The Tesy Compact 10 has an annual energy consumption of 573 kWh, placing it on the energy efficiency scale from A+ to F. This indicates that it is relatively energy-efficient, resulting in cost savings for the user compared to less efficient models.
Yes, the Tesy Compact 10 is equipped with LED indicators, providing users with visual feedback or notifications regarding the status or operation of the water heater and boiler.
The Tesy Compact 10 has a water tank capacity of 10 liters, suitable for small to medium-sized households or applications where a moderate amount of hot water is required.
To troubleshoot if the Tesy Compact 10 water heater & boiler is not providing hot water, follow these steps: 1. Check the safety return-valve: Regularly clean and inspect the safety return-valve to ensure it is functioning properly and not obstructed. Lime scale accumulation should be cleaned, especially in regions with highly calcareous water. 2. Verify the installation: Ensure that the appliance is mounted in premises outfitted with floor hydro insulation and plumbing drainage. Avoid placing non-waterproof objects under the appliance. If the appliance is installed in premises without floor hydro insulation, use a protective tub with plumbing drainage underneath. 3. Check for leakage: If the water heater is leaking, take measures to lead and collect the leakages to prevent damages. Make sure the protection valve is left open to the atmosphere. 4. Draining procedure: If the premise's temperature is expected to fall below 0°C, drain the water heater. Cut off its power supply before draining. Follow the specific draining procedure based on whether the boiler is installed above or under sinks. 5. Electrical connection: Ensure that the water heater is connected to the electrical network properly. If the power supply cord is damaged, it should be replaced by a qualified person. Make sure the appliance is filled with water before switching on the water heater. By following these troubleshooting steps, you can identify and resolve issues related to the Tesy Compact 10 water heater & boiler not providing hot water.
If the Tesy Compact 10 water heater & boiler is leaking water, you can follow these steps to address the issue: 1. Check the safety return-valve: Regularly clean and inspect the safety return-valve to ensure it is functioning properly and not obstructed. Lime scale accumulation should be cleaned, especially in regions with highly calcareous water. 2. Lead and collect the leakages: Take measures to lead and collect the leakages to prevent damages. Make sure the protection valve is left open to the atmosphere. 3. Verify the installation: Ensure that the appliance is mounted in premises outfitted with floor hydro insulation and plumbing drainage. Avoid placing non-waterproof objects under the appliance. If the appliance is installed in premises without floor hydro insulation, use a protective tub with plumbing drainage underneath. 4. Draining procedure: If the water heater is leaking and needs to be emptied, follow the specific draining procedure based on whether the boiler is installed above or under sinks. Cut off the power supply before draining. By following these steps, you can troubleshoot and address the issue of a leaking Tesy Compact 10 water heater & boiler.
To troubleshoot if the Tesy Compact 10 water heater & boiler is not heating the water to the desired temperature, you can follow these steps: 1. Check the safety return-valve: Regularly clean and inspect the safety return-valve to ensure it is functioning properly and not obstructed. Lime scale accumulation should be cleaned, especially in regions with highly calcareous water. 2. Verify the installation: Ensure that the appliance is mounted in premises outfitted with floor hydro insulation and plumbing drainage. Avoid placing non-waterproof objects under the appliance. If the appliance is installed in premises without floor hydro insulation, use a protective tub with plumbing drainage underneath. 3. Check for leakage: If the water heater is leaking, take measures to lead and collect the leakages to prevent damages. Make sure the protection valve is left open to the atmosphere. 4. Draining procedure: If the premise's temperature is expected to fall below 0°C, drain the water heater. Cut off its power supply before draining. Follow the specific draining procedure based on whether the boiler is installed above or under sinks. 5. Electrical connection: Ensure that the water heater is connected to the electrical network properly. If the power supply cord is damaged, it should be replaced by a qualified person. Make sure the appliance is filled with water before switching on the water heater. By following these troubleshooting steps, you can identify and resolve issues related to the Tesy Compact 10 water heater & boiler not heating the water to the desired temperature.
If the Tesy Compact 10 water heater & boiler is making unusual noises during operation, you can check the following: 1. Check for loose components: Inspect the water heater to ensure that all components, such as pipes, fittings, and valves, are securely fastened. Tighten any loose connections. 2. Verify water pressure: Check the water pressure in your premises. If the pressure is too high, it can cause the water heater to make noise. Adjust the pressure to the recommended level. 3. Check for air in the system: Bleed the air from the water heater system. Air trapped in the pipes can cause noise during operation. Follow the manufacturer's instructions to release the air from the system. 4. Inspect the heating element: If the noise is coming from the heating element, it may be damaged or worn out. In this case, it is recommended to contact a qualified technician to inspect and replace the heating element if necessary. By following these steps, you can identify and address the causes of unusual noises in the Tesy Compact 10 water heater & boiler during operation.
To troubleshoot if the Tesy Compact 10 water heater & boiler is not turning on or is not responding to the controls, you can follow these steps: 1. Check the power supply: Ensure that the water heater is properly connected to the electrical network. Verify that the power supply cord is not damaged and that the safety fuse is intact. If the power supply cord is damaged, it should be replaced by a qualified person. 2. Verify the water level: Make sure that the water heater is filled with water before turning it on. If the water level is too low, the water heater may not function properly. 3. Check the controls: Ensure that the controls on the water heater are set correctly. Verify that the temperature settings are appropriate and that the controls are not stuck or damaged. 4. Reset the water heater: If the water heater is not responding to the controls, try resetting it. Turn off the power supply, wait for a few minutes, and then turn it back on. This can sometimes resolve minor issues. 5. Contact customer support: If the above steps do not resolve the issue, it is recommended to contact the manufacturer's customer support or a qualified technician for further assistance. By following these troubleshooting steps, you can identify and address the reasons why the Tesy Compact 10 water heater & boiler is not turning on or not responding to the controls.
Yes, the manual of the Tesy Compact 10 is available in English .
Is your question not listed? Ask your question here
No results
Need help?
Do you have a question about the Tesy and is the answer not in the manual?
Question and answer