View the manual for the Philips InfraCare HP3631 here, for free. This manual comes under the category pain therapy appliances and has been rated by 1 people with an average of a 6.6. This manual is available in the following languages: English. Do you have a question about the Philips InfraCare HP3631 or do you need help? Ask your question here

The Philips InfraCare HP3631 is a pain therapy appliance designed to provide effective pain relief for muscles and joints. With a bulb power of 300W and a service life of 500 hours, this appliance delivers deep penetrating infrared warmth that improves blood circulation. The treatment area is 400 x 300 millimeters, making it suitable for targeting specific "zone" areas for relief. This pain therapy appliance features an adjustable tilt angle and height, allowing for customizable treatment options. The integrated timer enables users to set personal treatment times for added convenience. The soft-touch handgrip adds comfort during use, while the 2-meter cable length provides flexibility in placement. With dimensions of 200 millimeters in width, 309 millimeters in depth, and 172 millimeters in height, this appliance is compact and easy to use. The AC input voltage is 230V, ensuring consistent performance. Weighing 1.4 kilograms, the Philips InfraCare HP3631 is lightweight and portable for on-the-go pain relief. Overall, the Philips InfraCare HP3631 offers extra focused treatment with its 300W infrared halogen lamp and user-friendly design. It is a reliable option for those seeking effective pain relief at home.

| Brand | Philips |
| Model | InfraCare HP3631 | HP3631/01 |
| Product | pain therapy appliance |
| EAN | 0871010365193, 8710103194699, 8710103246015, 8710103246022, 8710103246039, 8710103291008, 8710103291015, 8710103337966, 8710103651932, 8710103256243 |
| Language | English |
| Filetype | User manual (PDF) |
| Bulb power | 300 W |
| AC input voltage | 230 V |
| AC input frequency | 50 - 60 Hz |
| Service life of lamp | 500 h |
| Tilt adjustment | Yes |
| Adjustable height | Yes |
| Integrated timer | Yes |
| Treatment area | 400 x 300 mm |
| On/off switch | Yes |
| Soft-touch handgrip | Yes |
| Certification | IEC 60601 & 60335, MD 2007/47/EC, MDD 93/42/EEC |
| Therapy method | Infrared |
| Cord length | 200 m |
| Cable length | 2 m |
| Product color | White |
| Power | 300 W |
| Quantity per EUR-pallet | 60 pc(s) |
| F-box weight | 1.8 g |
| Number of F-boxes per A-box | 3 pc(s) |
| A-box weight | 5.4 g |
| Country of origin | Germany |
| Width | 200 mm |
| Depth | 309 mm |
| Height | 172 mm |
| Weight | 1.4 g |
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Philips InfraCare HP3631 below.
The Philips InfraCare HP3631 has a weight of 1.4 g.
The Philips InfraCare HP3631 has the following certifications: IEC 60601 & 60335, MD 2007/47/EC, MDD 93/42/EEC.
The Philips InfraCare HP3631 has a height of 172 mm.
The Philips InfraCare HP3631 has a width of 200 mm.
The Philips InfraCare HP3631 has a depth of 309 mm.
Yes, the Philips InfraCare HP3631 has a bulb power of 300 W. This is a relatively high power which means that the appliance can deliver a strong and effective pain therapy treatment.
Yes, the Philips InfraCare HP3631 has a service life of lamp of 500 h. This means that the lamp will last for a long time before needing to be replaced, ensuring that the appliance can be used for multiple pain therapy treatments without any issues.
Yes, the Philips InfraCare HP3631 has tilt adjustment. This feature allows the user to adjust the angle of the appliance, making it easier to target specific areas of the body for pain therapy treatment.
Yes, the Philips InfraCare HP3631 has an adjustable height. This feature allows the user to customize the height of the appliance according to their needs, ensuring optimal positioning for pain therapy treatment.
Yes, the Philips InfraCare HP3631 has an integrated timer. This feature allows the user to set a specific duration for the pain therapy treatment, ensuring that it is consistent and controlled. This is a convenient feature that helps the user to easily manage their pain therapy sessions.
To adjust the angle of the light beam on the Philips InfraCare HP3631 pain therapy appliance, follow these steps: 1. Place the appliance on a stable, level surface with at least 25 cm of free space around it to prevent overheating. 2. Identify the lamp housing, which contains the infrared halogen lamp. 3. Locate the adjustable angle feature on the lamp housing. 4. To tilt the light beam forwards, gently push the lamp housing towards the front. 5. To tilt the light beam backwards, gently pull the lamp housing towards the back. 6. Adjust the angle of the light beam according to your desired position for treatment. 7. Ensure that the lamp housing is securely positioned in the desired angle before use. By following these steps, you can easily adjust the angle of the light beam on the Philips InfraCare HP3631 pain therapy appliance to target specific areas for pain relief and treatment.
If the Philips InfraCare HP3631 pain therapy appliance does not emit infrared light, you can try the following steps: 1. Check the power supply: Ensure that the appliance is properly connected to a power source and that the power cord is securely plugged into an electrical outlet. 2. Verify the lamp: Make sure that the infrared halogen lamp is correctly installed in the lamp housing. If it is not, carefully insert the lamp into the housing until it is securely in place. 3. Check the filter: Inspect the filter located on the appliance and ensure that it is clean and free from any obstructions. If the filter is dirty or clogged, gently clean it using a soft cloth or brush. 4. Reset the appliance: If the above steps do not resolve the issue, try resetting the appliance by turning it off and unplugging it from the power source for a few minutes. Then, plug it back in and turn it on again. 5. Contact customer support: If the appliance still does not emit infrared light after following these steps, it is recommended to contact Philips customer support for further assistance. They will be able to provide specific troubleshooting guidance or arrange for repairs if necessary. By following these steps, you can troubleshoot the issue of the Philips InfraCare HP3631 pain therapy appliance not emitting infrared light.
To properly unwind the mains cord before using the Philips InfraCare HP3631 pain therapy appliance, follow these steps: 1. Locate the mains cord attached to the appliance. 2. Ensure that the appliance is turned off and unplugged from the power source. 3. Hold the plug firmly and gently pull the mains cord straight out from the appliance. 4. Avoid twisting or bending the cord excessively to prevent damage. 5. Continue pulling the cord until it is fully unwound and straightened. 6. Inspect the cord for any signs of damage, such as cuts or frayed wires. If any damage is found, do not use the appliance and contact customer support for assistance. 7. Once the cord is unwound and checked for damage, you can proceed to connect the appliance to a power source and use it as intended. By following these steps, you can properly unwind the mains cord of the Philips InfraCare HP3631 pain therapy appliance before using it, ensuring safe and effective operation.
If the Philips InfraCare HP3631 pain therapy appliance overheats during use, follow these steps: 1. Immediately turn off the appliance and unplug it from the power source. 2. Allow the appliance to cool down for at least 10 minutes before handling or attempting to use it again. 3. Check the surrounding environment to ensure proper ventilation. Make sure there is enough space around the appliance for air to circulate freely. 4. Inspect the appliance for any obstructions that may be blocking the airflow, such as dust or debris. If any obstructions are found, carefully clean them using a soft cloth or brush. 5. Verify that the infrared halogen lamp is securely installed in the lamp housing. If it is loose or improperly positioned, adjust it accordingly. 6. If the appliance continues to overheat after following these steps, it is recommended to contact Philips customer support for further assistance. They will be able to provide specific troubleshooting guidance or arrange for repairs if necessary. By following these steps, you can address the issue of the Philips InfraCare HP3631 pain therapy appliance overheating during use and ensure safe and effective operation.
To clean the filter on the Philips InfraCare HP3631 pain therapy appliance, follow these steps: 1. Unplug the appliance from the power source and allow it to cool down for approximately 15 minutes before cleaning. 2. Use a damp cloth to clean the lamp housing and the base of the appliance. Take care to prevent water from entering the appliance. 3. For the outer surface of the filter, you can clean it with a soft cloth dampened with a small amount of rubbing alcohol. 4. Avoid using abrasive substances such as cleaners, solvents, or acetone to clean the appliance. 5. After cleaning, ensure that the filter is completely dry before reassembling and using the appliance again. It is important to clean the filter regularly to maintain the performance and effectiveness of the Philips InfraCare HP3631 pain therapy appliance. By following these steps, you can keep the filter clean and ensure optimal functioning of the appliance.
Yes, the manual of the Philips InfraCare HP3631 is available in English .
Is your question not listed? Ask your question here
No results
Need help?
Do you have a question about the Philips and is the answer not in the manual?
Question and answer