On the menu screen, select [SIGNAL LIST] from the main menu.
Refer to “Navigating through the menu” (x page 65) for the operation of the menu screen.
r Registered signal details
A1 (1-2)
When the address number (A1, A2, ... L7, L8) signal is registered
Sub memory number
Memory number:
fA name can be set for each sub memory (x page 129).
Registering new signals
After a new signal is input and the <MENU> button on the remote control or the control panel is pressed, the registration is completed and the
[MAIN MENU] screen is displayed.
Note
fUp to 96 signals, including sub memories, can be registered to the projector.
fThere are 12 pages (eight memories of A through L, with eight memories possible on each page) for memory numbers, and the signal is
registered to the lowest number that is available. If there is no available memory number it will be overwritten from the oldest signal.
fThe names to be registered are automatically determined by the input signals and memory numbers.
fIf a menu is being displayed, the new signals will be registered at the instant they are input.
Renaming the registered signal
Registered signals can be renamed.
1) Press asqw to select the signal of which name is to be changed.
2) Press the <ENTER> button.
fThe [REGISTERED SIGNAL STATUS] screen is displayed.
fThe memory number, input terminal, input signal name, frequency, synch polarity, etc., are displayed.
fPress the <MENU> button to return to the [SIGNAL LIST] screen.
3) Press the <ENTER> button.
fThe [REGISTERED SIGNAL SETUP] screen is displayed.
4) Press as to select [SIGNAL NAME CHANGE].
5) Press the <ENTER> button.
fThe [SIGNAL NAME CHANGE] screen is displayed.
6) Press asqw to select the text, and press the <ENTER> button to enter the text.
7) After the name is changed, press asqw to select [OK], and press the <ENTER> button.
fThe registration is completed and the [REGISTERED SIGNAL SETUP] screen returns.
fWhen pressing asqw to select [CANCEL] and pressing the <ENTER> button, the changed signal name will not be registered and
an automatically registered signal name will be used.
Deleting the registered signal
Registered signals can be deleted.
1) Press asqw to select the signal to delete.
Manual
View the manual for the Panasonic PT-DX100EWJ here, for free. This manual comes under the category video projectors and has been rated by 1 people with an average of a 6.9. This manual is available in the following languages: English. Do you have a question about the Panasonic PT-DX100EWJ or do you need help? Ask your question here