Panasonic BT-LH1760 manual

Panasonic BT-LH1760
7.5 · 1
PDF manual
 · 44 pages
English
manualPanasonic BT-LH1760
37
Priority of assigned functions
When both “MARKER1” and “MARKER2” are activated at the same time, “MARKER1” has priority. However,
when the display aspect ratio is 4:3, the “MARKER1” aspect ratio is 16:9 and the “MARKER2” aspect ratio is 4:3,
“MARKER2” is displayed. In this case, the “MARKER2” background is controlled.
When “MARKER BACK HALF” and “MARKER BACK BLACK” are activated at the same time, “MARKER BACK
BLACK” has priority.
During GPI edge operation and two or more of “INPUT SEL. VIDEO”, “INPUT SEL. SDI1”, “INPUT SEL. SDI2”,
“INPUT SEL. YP
BPR/RGB” and “INPUT SEL. DVI-D” are simultaneously activated, priority goes to the last
activated item. During level operation, priority is assigned in the following order: “INPUT SEL. VIDEO”, “INPUT
SEL. SDI1”, “INPUT SEL. SDI2”, “INPUT SEL. YP
BPR/RGB” and “INPUT SEL. DVI-D”.
When “GAMMA SEL. FILM” and “GAMMA SEL. STDIO/PST” are activated at the same time, “GAMMA SEL.
FILM” has priority.
The following diagram and the table on the lower right show RS-232C terminal pin arrangement and connections.
For details on systems using RS-232C, be sure to consult your dealer.
Connectors and signals
Connector: D-SUB 9-pin (female)
Signal
Communication parameters
Command format
The command is the 3-character string starting with
STX and ending with ETX.
Append any data after the colon (:) following the
command, as required.
Response formats
1. Setting command response
2. Query command response
3. Error response
Error codes
ER001: Invalid command
ER002: Parameter error

RS-232C terminal

PC Side (Straight) BT-LH1760/1710 Side
Pin number Signal Pin number Signal
1N.C. 1N.C.
2 RXD 2 TXD
RS-232C terminals (9P) 3 TXD 3 RXD
4DTR 4DSR
5GND 5GND
6DSR 6DTR
7 RTS 7 CTS
8 CTS 8 RTS
9N.C. 9N.C.

RS-232C remote control method

Pin number Signal Description
1 N.C. Not connected
2 TXD Transmission data
3 RXD Reception data
4 DSR Connected inside
5 GND Ground
6 DTR Connected inside
7 CTS Connected inside
8 RTS Connected inside
9 N.C. Not connected
Signal level RS-232C compliant
Synchro system Asynchronous
Transfer rate 9600 bps
Parity None
Data length 8 bit
Stop bit 1 bit
Flow control None
STX (02h) Command : Data ETX (03h)
STX (02h) Command ETX (03h)
STX (02h) Data ETX (03h)
STX (02h) Error code ETX (03h)

REMOTE Specifications (continued)

View the manual for the Panasonic BT-LH1760 here, for free. This manual comes under the category Monitors and has been rated by 1 people with an average of a 7.5. This manual is available in the following languages: English. Do you have a question about the Panasonic BT-LH1760 or do you need help? Ask your question here

Need help?

Do you have a question about the Panasonic and the answer is not in the manual? Ask your question here. Provide a clear and comprehensive description of the problem and your question. The better your problem and question is described, the easier it is for other Panasonic owners to provide you with a good answer.

Number of questions: 0

General
Panasonic
BT-LH1760
Monitor
English
User manual (PDF)

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Panasonic BT-LH1760 below.

Is your question not listed? Ask your question here

No results