To protect your device from damage, please observe the following:
• Store the device and the components in a clean, safe
location.
• Do not use any abrasive or volatile cleaners.
• Do not wash the device and any components or immerse
them in water.
• Do not use gasoline, thinners or similar solvents to clean the
device.
• Use a soft and dry cloth, or a soft and moistened cloth and
neutral soap to clean on the monitor and the arm cuff.
• Changes or modification not approved by the manufacturer
will void the user warranty. Do not disassemble or attempt to
repair the device or components. Consult Customer Service.
5.2 Storage
1. Unplug the air plug from the air jack.
2. Gently fold the air tube into the arm cuff.
Note: Do not bend or crease the air tube
excessively.
Do not store the device in the following situations:
•If the device is wet.
•Locations exposed to extreme temperatures, humidity, direct sunlight, dust or
corrosive vapors such as bleach.
•Locations exposed to vibrations, shocks or where it will be at an angle.
5.3 Optional Medical Accessories
Using the Optional AC Adapter
1. Insert the AC adapter plug
into the AC adapter jack on
the rear side of the monitor.
2. Plug the AC adapter into an
electrical outlet.
To disconnect the AC adapter, unplug the AC adapter from the electrical outlet
first, and then remove the AC adapter plug from the monitor.
6. Specifications
Notes:
• These specifications are subject to change without notice.
• In the clinical validation study, the 5th phase was used on 85 subjects for
determination of diastolic blood pressure.
• This device has not been validated for use on pregnant patients.
7. FCC Statement
FCC CAUTION
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
8. Limited Warranty
Your BP742N Automatic Blood Pressure Monitor, excluding the arm cuff and
batteries, is warranted to be free from defects in materials and workmanship
appearing within 2 years from the date of purchase, when used in accordance with
the instructions provided with the monitor. The arm cuff is warranted to be free from
defects in materials and workmanship appearing within 1 year from the date of
purchase when the monitor is used in accordance with the instructions provided
with the monitor. The above warranty extends only to the original retail purchaser.
We will, at our option, replace without charge any monitor or arm cuff covered by the
above warranty. Replacement is our only responsibility and your only remedy under
the above warranty.
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for
the address of the inspection center and the return shipping and handling fee.
Enclose the original printed receipt. Include a letter, with your name, address, phone
number, and description of the specific problem. Pack the product carefully to
prevent damage in transit. Because of possible loss in transit, we recommend
insuring the product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN
CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS ANY
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE
IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF
THE ABOVE EXPRESS WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL,
INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR
DAMAGES.
This warranty provides you with specific legal rights, and you may have other rights
that vary by jurisdiction. Because of special local requirements, some of the above
limitations and exclusions may not apply to you.
9. Guidance and Manufacturer’s Declaration
OMRON Automatic Blood Pressure Monitor
Information for accompanying documents in the scope of IEC60601-1-2:2007
Model: BP742N including AC-adapter
Error Display Cause Solution
Irregular heartbeats are
detected.
Remove the arm cuff. Wait 2 - 3
minutes and then take another
measurement. Repeat the steps
in section 3.3. If this error
continues to appear, contact
your physician.
Movement during measurement.
Carefully read and repeat the
steps in section 3.3.
The batteries are low.
You should replace the batteries
with new ones ahead of time.
Refer to section 2.1.
The batteries are exhausted.
You should replace the batteries
with new ones at once.
Refer to section 2.1.
Air plug disconnected.
Insert the plug securely.
Refer to section 3.1.
Arm cuff is applied too loosely.
Apply the arm cuff tighter.
Refer to section 3.1.
Air is leaking from the arm cuff.
Replace the arm cuff with a new
one.
Refer to section 5.3.
Movement during measurement
and the arm cuff has not been
inflated sufficiently.
Repeat measurement. Remain
still and do not talk during
measurement.
Refer to section 3.3.
If “E2” appears repeatedly,
inflate the arm cuff manually
until it is 30 to 40 mmHg above
your previous measurement
result.
Refer to section 3.3.
The arm cuff was inflated
exceeding the maximum
allowable pressure, and then
deflated automatically when
inflating the arm cuff manually.
Do not touch the arm cuff and/or
bend the air tube while taking a
measurement. Do not inflate the
arm cuff more than necessary.
Refer to section 3.3.
Movement during measurement.
Repeat measurement. Remain
still and do not talk during
measurement.
Refer to section 3.3.
Clothing is interfering with the
arm cuff.
Remove any clothing interfering
with the arm cuff.
Refer to section 3.1.
Device error. Contact Customer Service.
Problem Cause and Solution
No power.
No display appears on the monitor.
Replace all batteries with new ones.
Check the battery installation for proper
placement of the battery polarities.
Refer to section 2.1.
Measurement values appear too high or
too low.
Blood pressure varies constantly. Many
factors including stress, time of day, and
how you wrap the cuff, may affect your
blood pressure. Review the section 1.2
and section 3.3.
Arm cuff AC Adapter
Arm circumference
9” - 17” (22 - 42 cm)
CD-WR17
(Model: HEM-RML31)
HEM-ADPTW5
Model BP742N (HEM-7131-Z)DisplayLCD digital displayMeasurement rangePressure: 0 to 299 mmHgPulse: 40 to 180 beats / min.
AccuracyPressure: 3 mmHg or 2% of reading
Pulse: 5% of display readingInflationFuzzy-logic controlled by electric pumpDeflationAutomatic pressure release valveMeasurement methodOscillometric methodIP classificationIP 20Power source4 “AA” batteries 1.5V or optional AC adapter (INPUT AC100-240V 50/60Hz 0.12A)
Battery lifeApproximately 1000 measurements (using new alkaline batteries)
Operating temperature / humidity50°F to 104°F (10°C to 40°C) / 15 to 90% RHStorage temperature / humidity / air pressure-4°F to 140°F (-20°C to 60°C) / 10 to 95% RH / 700 to 1060hPa
WeightMonitor : Approximately 10 5/8 oz. (300g) not including batteries
Arm cuff : Approximately 5 3/4” 23 1/2” (air tube: 29 1/2”)
(145 mm 594 mm (air tube: 750 mm))Cuff circumference9” to 17” (220 to 420 mm)MemoryUp to 50 per userContentsMonitor, arm cuff, battery set, instruction manual, quick start guide
FOR CUSTOMER SERVICE
Visit our web site at:www.omronhealthcare.com
Call toll free:1-800-634-4350
= Type BF
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular)
telephones, medical devices in use may be susceptible to electromagnetic interference from
other devices. Electromagnetic interference may result in incorrect operation of the medical
device and create a potentially unsafe situation. Medical devices should also not interfere with
other devices.In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the IEC60601-1-2 standard has been implemented. This
standard defines the levels of immunity to electromagnetic interferences as well as maximum
levels of electromagnetic emissions for medical devices.Medical devices manufactured by OMRON Healthcare conform to this IEC60601-1-2:2007 standard for both immunity and emissions.Nevertheless, special precautions need to be observed:
•The use of accessories and cables other than those specified by OMRON, with the exception
of cables sold by OMRON as replacement parts for internal components, may result in increased emission or decreased immunity of the device.•The medical devices should not be used adjacent to or stacked with other equipment.In case adjacent or stacked use is necessary, the medical device should be observed to verify normal operation in the configuration in which it will be used.•Refer to further guidance below regarding the EMC environment in which the device should be used.•The MEDICAL ELECTRICAL EQUIPMENT BP742N including AC-adapter needs special
precautions regarding EMC and needs to be installed and put into service according to the
EMC information provided in this documentations.
•The Essential Performance of the BP742N including AC-adapter is to measure a blood
pressure and a pulse rate and using the memory function.The BP742N including AC-adapter may be interfered with by other equipment, even if that other equipment complies with CISPR EMISSION requirements.
Guidance and manufacturer’s declaration - electromagnetic immunity
OMRON BP742N including AC-adapter is intended for use in the electromagnetic environment
specified below. The customer or the user of this OMRON BP742N including AC-adapter should
View the manual for the Omron BP742N here, for free. This manual comes under the category sphygmomanometer and has been rated by 5 people with an average of a 8.3. This manual is available in the following languages: English. Do you have a question about the Omron BP742N or do you need help? Ask your question here
Need help?
Do you have a question about the Omron and is the answer not in the manual?
Receive updates on solutions
Get answers to your question
Question and answer
Number of questions: 44
E
EdJanuary 11, 2023
How do you reset memory to start like new?
1 comment
E
Emma of manua.lsOctober 26, 2023
To reset the memory of the Omron BP742N sphygmomanometer and start anew, follow these steps:
1. Press and hold the START/STOP button for more than 3 seconds.
2. Release the START/STOP button when the Date/Time display turns off.
3. The arm cuff will start to inflate automatically.
4. The USER ID symbol and the Date/Time display will disappear, indicating that the memory has been reset.
This answer is automatically generated
J
Josana BerdzinskiNovember 20, 2020
1) Should the cuff clear the elbow area when applying to the upper arm?
2) Do you have a bigger cuff---I have a large upper arm?
G
GraceFebruary 25, 2021
Why is my device getting power but is silent and not recording blood pressure but showing a display of 0 and E1?
M
MyraOctober 15, 2023
If I remove the batteries and replace them, will I lose all the memory? I discovered that the date and time are not set correctly so I want to set that.
T
TFMay 27, 2021
Cuff seems to be unusually tight when taking pressure, is this normal. And I mean way tighter than they do it at the doctors office
D
Debra BerronesJune 16, 2021
Does the BP742N process averages of multiple readings daily, such as 3 readings in the morning?
L
Lula WintersJanuary 3, 2023
Won't monitor BP it starts to then stops image E l shows up on the screen..
M
MaryannJanuary 22, 2023
If my arm is 16 inches is this cuff suitable to use.
The cuff says 9-17 inches
Is this cuff considered to be adult or adult large
Using Omron BP742N
ד
דודי שלמהMay 2, 2024
How to reset omron monitir
Model bp742n received on display E1
The Omron BP742N is an automatic sphygmomanometer specifically designed for measuring blood pressure on the upper arm. It supports placement on the upper arm and can be used by up to two users. With a memory register of 100, it allows users to track and store blood pressure readings over time for future reference.
The Omron BP742N does not provide measurements for mean arterial pressure, pulse rate, diastolic blood pressure, or systolic blood pressure. However, it does include a memory function that allows users to compare and analyze their blood pressure readings. Furthermore, it does not have a speaking function but does come equipped with a heart rate monitor. This feature enables users to measure and monitor their heart rate in addition to their blood pressure.
For added convenience and power conservation, the Omron BP742N includes an auto power off feature that automatically turns off the device when not in use. Each pack includes one unit of the sphygmomanometer.
Overall, the Omron BP742N offers a reliable and durable solution for individuals who need to monitor their blood pressure. However, it is important to note that this description is strictly objective and does not provide any subjective evaluation or conclusion about the product.
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Omron BP742N below.
What does systolic pressure mean?
Systolic pressure is the top number that the blood pressure monitor will indicate. Systolic pressure refers to the amount of pressure in your arteries during the contraction of your heart muscle.
What does diastolilc pressure mean?
Diastolic pressure is the lowest number that the blood pressure monitor will indicate. The bottom number refers to your blood pressure when your heart muscle is between beats.
What is a normal blood pressure?
A normal blood pressure is about 120/80.
How can I properly position the cuff on my arm?
Place the cuff on your upper arm, ensuring that the air tube is aligned with your inner arm and the midpoint of the cuff is positioned at the same level as your heart.
What if I am experiencing discomfort or pain during the inflation of the cuff?
If you feel discomfort, ensure that the cuff is not wrapped too tightly or too loosely around your arm. The cuff should fit snugly but comfortably.
How can I ensure accurate measurements during each use?
Make sure to sit up straight in a chair with your back supported, feet flat on the floor, and legs uncrossed. Keep your arm relaxed and avoid talking or moving during the measurement.
What should I do if I obtain an inconsistent or irregular reading?
If the readings appear inconsistent, ensure that the cuff is properly placed and tightened. Relax for a few minutes in a calm environment before retrying the measurement.
Is there anything I need to know about maintaining my sphygmomanometer for long-lasting use?
To ensure accurate and reliable readings, it is essential to periodically check the cuff for wear or damage, regularly calibrate the device, and store it in a cool and dry place.
Does the Omron BP742N have a memory function?
Yes, the Omron BP742N has a memory function. This means that the device can store previous blood pressure readings, allowing users to track their blood pressure over time.
Does the Omron BP742N have a heart rate monitor?
Yes, the Omron BP742N has a heart rate monitor. This means that the device can measure the user's heart rate in addition to their blood pressure.
Is the Omron BP742N an automatic sphygmomanometer?
Yes, the Omron BP742N is an automatic sphygmomanometer. This means that the device inflates and deflates automatically, making it easier and more convenient for users to measure their blood pressure.
How many memory registers does the Omron BP742N have?
The Omron BP742N has 100 memory registers. This means that the device can store up to 100 blood pressure readings, allowing users to keep track of their blood pressure history.
Does the Omron BP742N have an auto power off feature?
Yes, the Omron BP742N has an auto power off feature. This means that the device will automatically turn off after a certain period of inactivity, helping to conserve battery life.
Is the manual of the Omron BP742N available in English?
Yes, the manual of the Omron BP742N is available in English .
Need help?
Do you have a question about the Omron and is the answer not in the manual?
Question and answer
Number of questions: 44How do you reset memory to start like new?
1 comment
To reset the memory of the Omron BP742N sphygmomanometer and start anew, follow these steps: 1. Press and hold the START/STOP button for more than 3 seconds. 2. Release the START/STOP button when the Date/Time display turns off. 3. The arm cuff will start to inflate automatically. 4. The USER ID symbol and the Date/Time display will disappear, indicating that the memory has been reset.
This answer is automatically generated1) Should the cuff clear the elbow area when applying to the upper arm? 2) Do you have a bigger cuff---I have a large upper arm?
Why is my device getting power but is silent and not recording blood pressure but showing a display of 0 and E1?
If I remove the batteries and replace them, will I lose all the memory? I discovered that the date and time are not set correctly so I want to set that.
Cuff seems to be unusually tight when taking pressure, is this normal. And I mean way tighter than they do it at the doctors office
Does the BP742N process averages of multiple readings daily, such as 3 readings in the morning?