Current regulations must be complied with when calculating the thermal power of radiators for installation.
When determining the number of elements in a radiator, remember that the nominal thermal power refers
to a
T – the difference between the average water temperature and the room temperature – of 50K.
Therefore, in order to save energy and improve environmental comfort, it is advisable to use for the system
a design
T of less than 50K, (e.g. 30K
÷
40K) and decrease the water delivery temperature.
The thermal power of radiators for values other than
T is obtained by multiplying the rated thermal power
by a coefficient C calculated from the formula:
C=(
T / 50 K)n
where n is the exponent of the equation Q=B
Tn
which expresses the thermal power of the heating element and is shown in the table for the various models.
This gives
Q(
T)=Q(50 K) x C
for automatic calculation go to Calculate
T
When determining the number of elements, remember that in installations in which the water enters and
leaves from the bottom or with a single- or double-pipe valve, the thermal power may drop to 10-12%
(fig. A) and 20%, respectively (fig. B), due to the particular water distribution inside the radiator. For radiators
installed below shelves, in alcoves or – worse still – when using radiator covers – the thermal power may
drop to 10-12% (fig. C).
for the first approximation go to Heating requirements calculation
(fig. C)
(fig. A) (fig. B)

RADIATOR DIMENSIONS

Manual

View the manual for the Nova Florida Seven S5 500/100 here, for free. This manual comes under the category heaters and has been rated by 1 people with an average of a 6.7. This manual is available in the following languages: English. Do you have a question about the Nova Florida Seven S5 500/100 or do you need help? Ask your question here

Need help?

Do you have a question about the Nova Florida and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Nova Florida Seven S5 500/100 specifications

Below you will find the product specifications and the manual specifications of the Nova Florida Seven S5 500/100.

General
BrandNova Florida
ModelSeven S5 500/100 | SEVEN S5 500/100
Productheater
LanguageEnglish
FiletypeUser manual (PDF)
Features
TypeRadiator
Operating fluidWater
Input connection typeG 1
Performance
Heating power116.3 W
Heating power (min)- W
Maximum operating pressure16 bar
Water capacity (section)0.33 L
Design
Product colorWhite
Housing materialAluminum
Placement optionsWall
Weight & dimensions
Width80 mm
Depth96 mm
Height557 mm
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Nova Florida Seven S5 500/100 below.

What is the ideal room temperature?

Most people find that the ideal room temperature is between 19 and 22 degrees Celsius.

What is the height of the Nova Florida Seven S5 500/100?

The Nova Florida Seven S5 500/100 has a height of 557 mm.

What is the width of the Nova Florida Seven S5 500/100?

The Nova Florida Seven S5 500/100 has a width of 80 mm.

What is the depth of the Nova Florida Seven S5 500/100?

The Nova Florida Seven S5 500/100 has a depth of 96 mm.

Is the manual of the Nova Florida Seven S5 500/100 available in English?

Yes, the manual of the Nova Florida Seven S5 500/100 is available in English .

Is your question not listed? Ask your question here

No results