*INSTALLATION*
39
In addition to insulating the exhaust
ducting, it is advisable to also install a
condensate trap for collecting and
evaporating any potential condensation.
Condensate traps for 125mm or
150mm diameter exhaust ducting are
available as optional accessories.
When installing a condensate trap,
ensure that it is positioned vertically
and as closely as possible to the cooker
hood above the exhaust connection.
The arrow on the casing indicates the
direction of airflow.
Miele shall not accept warranty claims
for any functional defects or damage
caused by inadequate exhaust
ducting.
Silencer
To reduce noise levels even further, a
silencer (optional accessory) can be
installed in the exhaust ducting.
In extraction mode, the silencer not only
reduces noise from the fan outside the
house, but also sounds originating
outside reaching the kitchen through
the exhaust ducting (e.g. traffic noise).
For this reason, the silencer must be
positioned as close as possible to the
ducting exit.

Manual

View the manual for the Miele DA 1260 es here, for free. This manual comes under the category exhaust hoods and has been rated by 1 people with an average of a 5.9. This manual is available in the following languages: English. Do you have a question about the Miele DA 1260 es or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Miele and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Miele DA 1260 es specifications

Below you will find the product specifications and the manual specifications of the Miele DA 1260 es.

General
BrandMiele
ModelDA 1260 es
Productexhaust hood
LanguageEnglish
FiletypeUser manual (PDF)

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Miele DA 1260 es below.

When should I replace the carbon filter on my extractor hood?

The carbon filter should be replaced every three to twelve months.

How often should I clean the metal hood grease filters?

The metal grease filters should be cleaned every eight to ten weeks.

Where can I find the model number of my cooker ectractor hood?

The model number of the hood is usually found on a white label inside the hood.

Is the manual of the Miele DA 1260 es available in English?

Yes, the manual of the Miele DA 1260 es is available in English .

Is your question not listed? Ask your question here

No results