View the manual for the Medisana USC here, for free. This manual comes under the category inhalators and has been rated by 4 people with an average of a 8. This manual is available in the following languages: English. Do you have a question about the Medisana USC or do you need help? Ask your question here

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Medisana USC below.
The Medisana USC has a weight of 300 g.
The Medisana USC has the following certifications: CE 0297.
Yes, the Medisana USC has an indication light. This is beneficial for the user as it provides visual feedback and alerts them to the device's status or any potential issues during usage.
The dimensions of the Medisana USC are 142 x 75 x 35 mm. These compact dimensions make it highly portable and convenient for the user to carry or store.
To properly attach the mask set to the Medisana USC inhalator, follow these steps: 1. Sit as upright as possible. 2. Plug the mask onto the nebulizer unit using the connecting piece. 3. Hold the mask lightly pressed over your nose, ensuring that it seals around the nose without being too tight. 4. Switch on the device by pressing the ON/OFF key. The equipment-on indicator lamp will light up. 5. Breathe in and out slowly and deeply through your nose. You can hold your breath for a short time after breathing in to improve the effectiveness of the therapy, although it is not necessary for general success. 6. Keep quiet and relaxed while breathing in and out regularly. Avoid inhaling too fast and take breaks if needed. 7. Hold the device as upright as possible during inhalation, but do not tilt it more than 45° in any direction. 8. An inhalation session should not exceed 15 minutes. 9. After terminating the inhalation, switch off the device using the ON/OFF key, even if you have not used up all the inhalant. The equipment-on indicator lamp will go out. 10. Clean the device immediately after each use. Please note that these steps are specific to the Medisana USC inhalator and may vary for other models or brands.
If the ultrasound frequency of the Medisana USC inhalator is not functioning properly, you can try the following steps to troubleshoot the issue: 1. Check the power supply: Ensure that the inhalator is properly connected to a power source and that the power supply is functioning correctly. If using batteries, make sure they are inserted correctly and not depleted. 2. Clean the nebulizer: Remove the nebulizer chamber from the inhalator and clean it according to the instructions provided in the manual. Build-up of residue or debris can affect the ultrasound frequency. 3. Check for obstructions: Inspect the nebulizer chamber and the mask set for any obstructions or blockages. Clear any debris or particles that may be hindering the ultrasound frequency. 4. Reset the device: If the ultrasound frequency issue persists, try resetting the inhalator. Turn off the device, disconnect it from the power source, and wait for a few minutes before reconnecting and turning it back on. 5. Contact customer support: If none of the above steps resolve the issue, it is recommended to contact Medisana customer support for further assistance. They can provide specific troubleshooting guidance or arrange for repairs if necessary. Remember to always refer to the instruction manual for detailed instructions and safety precautions specific to the Medisana USC inhalator.
To clean the nebulizer chamber of the Medisana USC inhalator, follow these steps: 1. Remove the batteries before cleaning the device. 2. Take off the attachments, cover, active ingredient tank, and nebulizer unit from the device. 3. Clean the device's casing and cover with a lightly moistened cloth soaked in mild soapy water. Avoid getting water inside the device. 4. Clean the used attachments (mouthpiece, mask, connection piece) under the tap. 5. After each use, clean the active ingredient tank and nebulizer unit. Put 8 ml of ethyl alcohol in the active ingredient tank without removing the nebulizer unit. Close the tank and leave the alcohol in for at least 10 minutes, shaking the unit gently from time to time. Then, empty the alcohol from the tank and repeat the procedure using water. 6. Disconnect the nebulizer unit from the active ingredient tank by turning it anticlockwise and pulling it off. Clean both parts again in freshwater. 7. Ensure that the nebulizer unit and active ingredient tank are properly dried before reassembling. 8. If there is medicine solution or dirt on the gold contacts between the device and the nebulizer unit, clean them with a cotton bud soaked in ethyl alcohol. Always refer to the instruction manual for detailed cleaning instructions and safety precautions specific to the Medisana USC inhalator.
If the Medisana USC inhalator does not turn on or operate as expected, you can try the following steps to troubleshoot the issue: 1. Check the power source: Ensure that the inhalator is properly connected to a power source, whether it is batteries or a power outlet. Make sure the batteries are inserted correctly and not depleted. 2. Verify the power switch: Check if the ON/OFF key is pressed correctly to turn on the device. Ensure that the equipment-on indicator lamp lights up, indicating that the device is powered on. 3. Clean the device: Clean the inhalator according to the cleaning instructions provided in the manual. Build-up of residue or debris can affect the device's functionality. 4. Reset the device: If the inhalator is not responding, try resetting it. Turn off the device, disconnect it from the power source, and wait for a few minutes before reconnecting and turning it back on. 5. Contact customer support: If the issue persists after trying the above steps, it is recommended to contact Medisana customer support for further assistance. They can provide specific troubleshooting guidance or arrange for repairs if necessary. Remember to always refer to the instruction manual for detailed instructions and safety precautions specific to the Medisana USC inhalator.
To store the Medisana USC inhalator and ensure its longevity, follow these steps: 1. Clean the device: Before storing the inhalator, make sure it is clean and free from any residue or debris. Refer to the cleaning instructions in the manual for proper cleaning guidelines. 2. Disconnect from the power source: If the inhalator is connected to a power outlet or using batteries, disconnect it from the power source before storing. 3. Remove attachments: Take off any attachments, such as the mask set or mouthpiece, from the inhalator. Clean and dry them separately before storing. 4. Store in a cool, dry place: Find a suitable location to store the inhalator, away from direct sunlight, moisture, and extreme temperatures. A cool and dry place, such as a cabinet or drawer, is ideal for preserving the device. 5. Protect from dust and dirt: Cover the inhalator with a clean cloth or place it in a protective case to prevent dust and dirt from accumulating on the device. 6. Avoid physical damage: Handle the inhalator with care to avoid any physical damage. Avoid dropping or mishandling the device during storage. By following these steps, you can properly store the Medisana USC inhalator and help maintain its longevity for future use.