Medisana TDP manual

Medisana TDP
9 · 6
PDF manual
 · 154 pages
English
manualMedisana TDP
DE

TENS-Schmerztherapiegerät TDP

GB

TENS Pain Therapy TDP

FR
Appareil pour la thérapie antidouleur TENS TDP
ES
Aparato de terapia antidolor TENS TDP
NL
TENS-pijntherapieapparaat TDP
GR
Συσκευή αλγοθεραπείας TENS TDP
Art. 88310
¡Por favor lea con cuidado!
A.u.b. zorgvuldig lezen!
Διαβάστε προσεκτικά!
Bitte sorgfältig lesen!
Please read carefully!
A lire attentivement s.v.p.!
Gebrauchsanweisung
Instruction Manual
Mode d’emploi
Instrucciones de manejo
Gebruiksaanwijzing
Οδηγίες χρήσης
0297

View the manual for the Medisana TDP here, for free. This manual comes under the category pain therapy appliances and has been rated by 6 people with an average of a 9. This manual is available in the following languages: English. Do you have a question about the Medisana TDP or do you need help? Ask your question here

Need help?

Do you have a question about the Medisana and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 1
A
AllenJuly 30, 2021

How to set memory?

The Medisana TDP is a pain therapy appliance designed to provide relief from various types of pain. It is equipped with advanced technology and features to effectively alleviate discomfort and promote relaxation. The appliance utilizes a combination of heat therapy and infrared radiation to target pain areas. The adjustable heat settings allow users to customize the intensity of the treatment according to their preferences and needs. The infrared radiation helps to penetrate deep into the affected tissues, promoting blood circulation and reducing inflammation. The Medisana TDP is compact and portable, making it convenient for use at home or on the go. It is designed to be user-friendly, with simple controls and an intuitive interface. The appliance is also equipped with safety features to ensure the well-being of the user, including automatic shut-off timers and overheat protection. The Medisana TDP is suitable for various types of pain, including muscle aches, joint pain, and menstrual cramps. It can be used on different parts of the body, such as the back, neck, legs, and abdomen. Additionally, the Medisana TDP is constructed with high-quality materials to ensure durability and longevity. It is built to withstand regular use and maintain its effectiveness over time. Overall, the Medisana TDP is a reliable and effective pain therapy appliance that provides targeted relief for a range of pain conditions. Its advanced features, portable design, and user-friendly interface make it a practical choice for those seeking pain relief at home or on the go.

General
BrandMedisana
ModelTDP | 88310
Productpain therapy appliance
EAN4015588883101
LanguageEnglish
FiletypeUser manual (PDF)
Technical details
Product colorGrey, White
Pulse rate range2 - 200 Hz
show more

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Medisana TDP below.

How do I adjust the frequency, pulse width, and waveform settings for the TENS pain therapy on the Medisana TDP pain therapy appliance?

To adjust the frequency, pulse width, and waveform settings for the TENS pain therapy on the Medisana TDP pain therapy appliance, follow these steps: 1. Turn on the Medisana TDP pain therapy appliance by pressing the power button. 2. Navigate to the settings menu using the control buttons on the device. 3. Select the TENS pain therapy mode from the available options. 4. Once in the TENS pain therapy mode, you can adjust the frequency, pulse width, and waveform settings. 5. To adjust the frequency, use the control buttons to increase or decrease the frequency value. The frequency is measured in Hertz (Hz) and determines the number of pulses per second. 6. To adjust the pulse width, use the control buttons to increase or decrease the pulse width value. The pulse width is measured in microseconds (μs) and determines the duration of each pulse. 7. To select the waveform, use the control buttons to cycle through the available waveform options. The waveform determines the shape of the electrical pulses. 8. Once you have adjusted the settings to your desired values, confirm the selection to start the TENS pain therapy session. Remember to consult the manual for more detailed instructions and recommended settings for your specific condition.

What should I do if the device is not providing any pain relief during the TENS pain therapy?

If the Medisana TDP pain therapy appliance is not providing any pain relief during the TENS pain therapy, you can try the following steps: 1. Check the electrode placement: Ensure that the electrodes are properly placed on the body according to the instructions in the manual. Make sure they are positioned close to the pain area or directly on the painful spots. 2. Verify the electrode connection: Ensure that the electrode cables are securely connected to the device. Check if the cables are inserted firmly into the sockets on the upper side of the device. Also, make sure that the electrodes are properly attached to the other end of the cables. 3. Adjust the settings: Check the frequency, pulse width, and waveform settings of the TENS pain therapy. Make sure they are set to the recommended values for your specific condition. Refer to the manual for guidance on adjusting these settings. 4. Consult your doctor: If the device is still not providing any pain relief, it is advisable to consult your doctor. They can provide further guidance on using the Medisana TDP pain therapy appliance and may recommend adjustments to the treatment plan. Remember to always follow the instructions provided in the manual and consult a healthcare professional for personalized advice regarding your specific condition.

How do I properly place the electrodes on my body for effective pain relief with the Medisana TDP pain therapy appliance?

To properly place the electrodes on your body for effective pain relief with the Medisana TDP pain therapy appliance, follow these steps: 1. Ensure that the electrodes are securely attached to the electrode cables. 2. Clean the area of your body where you will be placing the electrodes. Make sure the skin is dry and free from any lotions, oils, or creams. 3. Identify the pain area or the specific spot where you are experiencing discomfort. 4. Position the electrodes on or near the pain area. The exact placement may vary depending on your specific condition, so it is recommended to refer to the illustrations provided in the manual for guidance. 5. Make sure the electrodes are firmly pressed onto the skin to ensure good contact. 6. If using multiple electrodes, ensure that they are spaced apart to cover the entire pain area. 7. Once the electrodes are properly placed, you can start the TENS pain therapy session according to the instructions in the manual. Remember to consult the manual for more detailed instructions and illustrations on electrode placement for specific pain areas.

What should I check if the electrode cables are not securely connected to the device?

If the electrode cables are not securely connected to the Medisana TDP pain therapy appliance, you should check the following: 1. Ensure that the device is turned off before checking the connections. 2. Verify that the electrode cables are inserted firmly into the sockets on the upper side of the device. Make sure they are fully inserted and securely connected. 3. Check the connection between the electrode cables and the electrodes. Ensure that the cables are securely attached to the electrodes and that there are no loose connections. 4. Inspect the cables for any signs of damage, such as fraying or exposed wires. If any damage is found, replace the cables with new ones to ensure safe and effective use. 5. If the cables are detachable, try disconnecting and reconnecting them to ensure a proper connection. 6. If the issue persists, try using a different set of electrode cables to determine if the problem lies with the cables themselves. 7. If none of the above steps resolve the issue, consult the manual or contact Medisana customer support for further assistance. Remember to always handle the electrode cables with care and follow the instructions provided in the manual for proper connection and usage.

What should I do if I am unsure about the polarity of the electrodes during muscle stimulation with the Medisana TDP pain therapy appliance?

If you are unsure about the polarity of the electrodes during muscle stimulation with the Medisana TDP pain therapy appliance, follow these steps: 1. Turn off the Medisana TDP pain therapy appliance before making any adjustments. 2. Identify the two electrodes that are connected to the device. 3. Take note of the color-coding or labeling on the electrodes. Typically, one electrode is marked as positive (+) and the other as negative (-). 4. If the electrodes are not color-coded or labeled, you can determine the polarity by observing the shape or design of the electrodes. Some electrodes have distinct shapes or markings to indicate their polarity. 5. If you are still unsure about the polarity, you can perform a simple test. Connect one electrode to the positive socket and the other electrode to the negative socket on the device. Start the muscle stimulation session with these connections. 6. Pay attention to the sensation and muscle response during the session. If you feel the desired muscle contraction and stimulation, you have likely connected the electrodes correctly. If not, try swapping the connections, i.e., connecting the electrode that was previously in the positive socket to the negative socket, and vice versa. 7. Once you have determined the correct polarity, you can proceed with the muscle stimulation session using the Medisana TDP pain therapy appliance. Remember to always follow the instructions provided in the manual and consult a healthcare professional if you have any concerns or questions about using the device.

Is the manual of the Medisana TDP available in English?

Yes, the manual of the Medisana TDP is available in English .

Is your question not listed? Ask your question here

No results