View the manual for the Medisana MTX CONNECT here, for free. This manual comes under the category sphygmomanometer and has been rated by 1 people with an average of a 5.8. This manual is available in the following languages: English. Do you have a question about the Medisana MTX CONNECT or do you need help? Ask your question here
| Brand | Medisana |
| Model | MTX CONNECT |
| Product | sphygmomanometer |
| Language | English |
| Filetype | User manual (PDF) |
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Medisana MTX CONNECT below.
Systolic pressure is the top number that the blood pressure monitor will indicate. Systolic pressure refers to the amount of pressure in your arteries during the contraction of your heart muscle.
Diastolic pressure is the lowest number that the blood pressure monitor will indicate. The bottom number refers to your blood pressure when your heart muscle is between beats.
A normal blood pressure is about 120/80.
To set the alarm times for the two users on the Medisana MTX CONNECT sphygmomanometer, follow these steps: 1. Ensure the device is in standby mode and select your user memory. 2. Press the TIMER button followed by the MEMO button and hold both until the alarm symbol appears on the display. 3. Release both buttons, and "1" will flash for Alarm 1. You can use the MEMO button to select Alarm 1 or Alarm 2. 4. Press the TIMER button, and the display for entering the alarm time will flash. 5. Use the MEMO button to input the alarm time. 6. Press the TIMER button again, and the alarm symbol will flash. Use the MEMO button to toggle between alarm on and off. 7. Confirm your entries by pressing the TIMER button.
To switch between single measurement and 3 consecutive measurements on the Medisana MTX CONNECT sphygmomanometer, follow these steps: 1. Press and hold the TIMER button until the symbol for 3 consecutive measurements (3MAM mode) and " " start flashing on the display. 2. Press the MEMO button to select either " " for 3MAM mode or " " for single measurement. 3. Confirm your selection by pressing the START button or press the TIMER button for the next setting. 4. The device will now be set to either perform a single measurement or 3 consecutive measurements for calculating an average value.
To complete the settings required for the 3MAM measuring method on the Medisana MTX CONNECT sphygmomanometer, follow these steps: 1. Press the START button to initiate a self-test. Once completed, " " will appear on the display with 5 short beeps. 2. Switch between single measurement and 3 consecutive measurements by pressing and holding the TIMER button until the 3MAM mode symbol and " " start flashing. 3. Use the MEMO button to select the 3MAM measuring method symbol " " or the single measurement symbol " ". 4. Confirm your selection by pressing the START button. 5. Ensure you have completed any necessary settings as per the manual sections 3.3, 3.5, and 3.7 before using the 3MAM measuring method.
Yes, the manual of the Medisana MTX CONNECT is available in English .