Honeywell RLV4305 manual

Honeywell RLV4305
6.2 · 1
PDF manual
 · 20 pages
English
manualHoneywell RLV4305

Owner’s Manual

Read and save these
instructions.
For help please visit
honeywellhome.com

RLV4305A1000

Programmable

Thermostat

Application

This thermostat is designed to control an electric heating system such as a baseboard
heater, a radiant ceiling, a convector or a fan-forced heater.
The thermostat CANNOT be used with:
a resistive load under 0.83 A
a resistive load over 14.6 A
a system driven by a contactor or a relay (inductive load)
a central heating system.
WARNING Electrical Shock Hazard.
This thermostat is a line voltage control (120240 Volts). Do not install it if you
are not completely familiar with house wiring. If handled improperly, there is risk
of electric shock hazard, which may cause serious injury or death.
Do you need assistance? We are here to help.
Call 18008312823 for wiring assistance before returning the
thermostat to the store.

View the manual for the Honeywell RLV4305 here, for free. This manual comes under the category smart home and has been rated by 1 people with an average of a 6.2. This manual is available in the following languages: English. Do you have a question about the Honeywell RLV4305 or do you need help? Ask your question here

Need help?

Do you have a question about the Honeywell and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 12
M
Michael Chambers March 16, 2023

The power went on for days and now my RLV4305 is not working and shows no display. There is power going to the thermostat but does nothing . What is wrong thanks

The power went on for days and now my RLV4305 is not working and shows no display. There is power going to the thermostat but...
zoom-in
View photo
1 comment
E
Emma of manua.lsDecember 21, 2023

Based on the information from the manual of the Honeywell RLV4305 smart home thermostat, if the thermostat is not working and there is no display, you can try the following steps: 1. Check the clock and day settings. Press the Day button to set the correct day, and use the Hour and Min buttons to set the clock. Press the Return button to exit. It is important to set the clock when the time is incorrect or flashing on the screen. 2. If the basic settings are correct, you can try accessing the advanced settings. Press and hold the Program button for 3 seconds. Use the Program button to display the next parameter, and use the Up or Down button to modify the displayed parameter. To exit the menu, press the Return button or do not press any button for 1 minute. 3. Make sure the thermostat is receiving power. Check the power source and ensure it is properly connected. If the above steps do not resolve the issue, please refer to the manual for further troubleshooting.

This answer is automatically generated
R
Ronald J CwynarJanuary 18, 2020

why does the heat intensity indicator go from full to just a few lines when running. its telling me its still running or is it saving me energy

D
Doug VagieSeptember 29, 2023

can i just pick a temperature and have it go on to it reaches the temp and shut off. and do nothing else?

J
jeffrey P pailFebruary 5, 2024

I just bought a house with a RLV4305 thermostat. and it is programed and working although nobody has any idea on how to use it or change it. How can I set it for 55 until I am moved which will be in a few months

F
Frank GenovaFebruary 17, 2021

I have a Honeywell RLV4305 thermostat that I recently purchased this summer. I put it on a Natural gas tube heater. when it reaches the correct temperature it shuts off then about a minute latter it turns back on then a minute latter it shuts back off this happens over and over.

K
KellySeptember 29, 2023

We installed a new RLV4305. Whenever I push ANY button, the screen changes automatically, cycling through 3 different screens (1st screen is in photo) then it shows 2.5 then 11.9 and then back to normal screen). I am unable to program, change the time, manually change the temperature...I'm totally baffled as to what might be going on.

We installed a new RLV4305. 

Whenever I push ANY button, the screen changes automatically, cycling through 3 different scr...
zoom-in
View photo
3 comments
B
BrianNovember 27, 2023

Have you figured this out? I have the same issue

G
GregJanuary 8, 2024

I have seen this exact scenario with several of my RLV4305 T-stats. Sometimes the screen is totally blank (with power on). Seems to be intermittent. Might be related to minor fluctuations in line voltage, but not at all sure. Any advice on this would be appreciated.

S
ShaunFebruary 27, 2024

@Kelly I installed 3 of these in my house about 2.5yrs ago and have loved them. Just last night I experienced the very thing you are. I killed the power to the house to “hard boot it” and it worked all day… until just now. Trying to troubleshoot further and will keep an eye on this page or report back if I figure it out.

J
JudithApril 16, 2022

I would like to lower the heat but don't know how to work it

2 comments
T
thomAS BARBERMarch 18, 2023

I WOULD LOVE A MANUIAL BUT HOW I GET ONE . I DONT KNOW HOW TO RAISE OR LOWER THE TEMPITURE.

S
ShaunFebruary 27, 2024

@Judith open the face of the thermostat. There are basic instructions in there. Most functions start with pushing “program”.

M
Maureen DomingueOctober 13, 2020

I just want to raise the heat and set for 7 days a week

A
AprilOctober 3, 2021

Is there a video on how to install this

F
FelipeDecember 19, 2023

How can I turn off the thermostat?

The Honeywell RLV4305 is a smart home thermostat that allows for easy temperature control and energy savings. This thermostat is designed with simplicity in mind, featuring a minimalist and user-friendly interface. With its sleek and compact design, the Honeywell RLV4305 seamlessly blends into any home decor. It offers precise temperature control with its programmable settings, allowing users to set customized heating schedules to fit their preferences and lifestyle. This thermostat also has adaptive capabilities, learning from user behaviors and adjusting accordingly to optimize energy usage. The Honeywell RLV4305 is compatible with most heating systems, including electric baseboard heaters and convectors. It is easy to install and can be mounted on the wall for convenience. Furthermore, this thermostat has a built-in high-precision temperature sensor that ensures accurate readings for more precise heating control. To enhance energy efficiency, the Honeywell RLV4305 features a convenient energy-saving mode, helping users reduce energy consumption and lower their bills. It also offers a vacation mode, which allows users to set specific temperature settings while they are away from home. In addition, this smart thermostat is equipped with a backlit display for easy readability in any lighting condition. Its clear and intuitive interface makes it effortless to navigate through the various settings and temperature adjustments. Overall, the Honeywell RLV4305 is a reliable and efficient smart home thermostat, offering precise temperature control, energy-saving features, and a user-friendly interface.

General
BrandHoneywell
ModelRLV4305 | RLV4305A1000/E
Productsmart home
EAN0085267705783
LanguageEnglish
FiletypeUser manual (PDF)

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Honeywell RLV4305 below.

How do I change the temperature on my Honeywell RLV4305 thermostat?

To adjust the temperature on your Honeywell RLV4305 thermostat, simply press the up or down arrow buttons located on the front panel until you reach your desired temperature.

How can I program a specific heating schedule on my Honeywell RLV4305?

To set a heating schedule on your Honeywell RLV4305, press the "Program" button on the front panel. Use the arrow buttons to select the desired day and time slot, then set the temperature using the up or down arrows. Repeat this process for each day and time slot you wish to program.

What should I do if the display on my Honeywell RLV4305 is not working properly?

If the display on your Honeywell RLV4305 is not functioning correctly, first ensure that the thermostat is receiving power. Check the circuit breaker or fuse to confirm there is electricity. If the issue persists, try replacing the batteries. If the problem still persists, it may require professional assistance.

Can I disable the heating function on my Honeywell RLV4305 thermostat temporarily?

Yes, you can temporarily disable the heating function on your Honeywell RLV4305 thermostat. Simply press the "Mode" button on the front panel until the display shows "Off." This will prevent the thermostat from activating the heating system until you re-enable it.

How do I reset my Honeywell RLV4305 thermostat to its default settings?

To reset your Honeywell RLV4305 thermostat to its default settings, locate the reset button on the front panel or in the battery compartment. Use a paperclip or a pointed object to gently press and hold the reset button for about 5 seconds. This will reset the thermostat to its original factory settings.

Is the manual of the Honeywell RLV4305 available in English?

Yes, the manual of the Honeywell RLV4305 is available in English .

Is your question not listed? Ask your question here

No results