RECEIVING THE AIR CONDITIONER

Inspect the air conditioner. Check for concealed damage that may have occurred during shipment. Look for dents,
scratches, loose assemblies, evidence of oil, etc. Damage evident upon receipt should be noted on the freight bill.
Damage should be brought to the attention of the delivering carrier -- NOT to nVent Equipment Protection -- within
15 days of delivery. Save the carton and packing material and request an inspection. Then le a claim with the
delivering carrier.
nVent Equipment Protection cannot accept responsibility for freight damages; however, we will assist you in any
way possible.

HANDLING AND TESTING THE AIR CONDITIONER

If the air conditioner has been in a horizontal position, be certain it is placed in an upright, vertical or mounting
position for a minimum of ve (5) minutes before operating.
Do not attempt to operate the air conditioner while it is horizontal
or on its side, back or front. The refrigeration compressor is lled
with lubricating oil. This will cause permanent damage to the air
conditioner and also voids the warranty.

CAUTION

TEST FOR FUNCTIONALITY BEFORE MOUNTING THE AIR CONDITIONER TO THE ENCLOSURE.
Refer to the nameplate for proper electrical current requirements, and then connect the power cord to a properly
grounded power supply. Minimum circuit ampacity should be at least 125% of the amperage shown in the
design data section for the appropriate model. No other equipment should be connected to this circuit to prevent
overloading.
Operate the air conditioner for ve (5) to ten (10) minutes. No excessive noise or vibration should be evident
during this run period. The condenser blower (ambient air), the evaporator blower (enclosure air), and the
compressor should be running.
Condenser air temperatures should be warmer than normal room temperatures within a few minutes.
The compressor is provided with automatic reset thermal overload protection. This thermo-switch is located
and mounted inside the plastic enclosure clipped to the compressor. The switch operates when the compressor
overheats due to clogged or dirty inlet air lter or if ambient air temperatures exceed nameplate rating or if
enclosure dissipated heat loads exceed the rated capacity of the air conditioner. The thermal overload switch
will actuate and stop compressor operation. The blowers will continue to operate and the compressor will restart
after it has cooled to within the thermal overload cut-in temperature setting.

Manual

View the manual for the Hoffman T150126G120 here, for free. This manual comes under the category air-conditioning and has been rated by 1 people with an average of a 7.8. This manual is available in the following languages: English. Do you have a question about the Hoffman T150126G120 or do you need help? Ask your question here

Need help?

Do you have a question about the Hoffman and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Hoffman T150126G120 specifications

Below you will find the product specifications and the manual specifications of the Hoffman T150126G120.

General
BrandHoffman
ModelT150126G120 | T150126G120
Productair-conditioning
LanguageEnglish
FiletypeUser manual (PDF)
Technical details
Product colorGray
Housing materialMetal
Features
Product colorGray
TypeAir conditioner indoor unit
Multi-split-
Air conditioner functionsCooling
Ionizer-
Inverter technology-
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)-
Seasonal efficiency rating (heating) (SCOP)-
Seasonal efficiency rating (cooling) (SEER)-
Seasonal efficiency rating (heating) (SCOP) (Average heating season)-
Seasonal efficiency rating (heating) (SCOP) (Colder heating season)-
Cooling capacity (min)900 BTU/h
Cooling capacity in watts (nominal)264 W
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)- W
Heating capacity in watts (nominal) (Colder heating season)- W
Refrigerating mediumR134A
Refrigerating medium weight113 g
Operating temperature (cooling) (T-T)-40 - 55 °C
Power
Energy efficiency class (heating) (Average heating season)-
Energy efficiency class (heating) (Colder heating season)-
Hourly energy consumption (heating)- kWh
Annual energy consumption (cooling)- kWh
Hourly energy consumption (cooling)- kWh
Annual energy consumption (heating) (Warmer heating season)- kWh
Annual energy consumption (heating) (Average heating season)- kWh
Annual energy consumption (heating) (Colder heating season)- kWh
AC input voltage100 - 115 V
AC input frequency50 - 60 Hz
Design load (cooling)- kW
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)- kW
Design load (heating) (Colder heating season)- kW
Energy efficiency class (cooling)-
Energy efficiency class (heating) (Warmer heating season)-
Indoor unit
Indoor unit noise level (high speed)53 dB
Indoor unit width191 mm
Indoor unit depth160 mm
Indoor unit height400 mm
Indoor unit weight12000 g
Network
Wi-Fi-
Outdoor unit
Outdoor unit noise level- dB
Certificates
CertificationUL/cUL Listed\nCE\nEAC
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Hoffman T150126G120 below.

What certifications does the Hoffman T150126G120 have?

The Hoffman T150126G120 has the following certifications: UL/cUL Listed\nCE\nEAC.

What does BTU stand for?

BTU stands for British Thermal Unit and is a unit used to indicate cooling power.

What does R-410A stand for?

R-410A is a refrigerant used in machines that cool to zero degrees Celsius.

How often should I clean the filters of my Hoffman air conditioner?

The cleaner the filters, the better the air quality. This is why it is recommended to clean the filters of your Hoffman air conditioner at least four times a year.

What energy label does the Hoffman T150126G120 have?

The Hoffman T150126G120 has energy label -.

Is the manual of the Hoffman T150126G120 available in English?

Yes, the manual of the Hoffman T150126G120 is available in English .

Is your question not listed? Ask your question here

No results