Location Requirements

Electrical Requirements

The portable air conditioner should be dedicated to a 115V, 60
Hz, 15-amp fuse grounded 3 prong outlet.
The use of a time-delay fuse or time-delay circuit breaker is
required.
All wiring must comply with local and the national electrical
codes and be installed by a qualified electrician. If you have
any questions, contact a qualified electrician.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,

WARNING

fire, or electrical shock.
NOTES:
The flexible exhaust hose allows placement of the air
conditioner between 23⁵⁄₈" and 64 " (60 cm and 163 cm)
from window or door
Confirm you are using the correct size air conditioner for the
space to be cooled, per sizing recommendations, below:
¹⁄₈
Vertical Slide Widow
NOTES:
To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least
23⁵⁄₈" (60 cm).
Do not block the air outlet.
Provide easy access to the grounded 3 prong outlet.
23⁵⁄₈" - 64¹⁄₈"
(60 cm - 163 cm)
Horizontal Slide Window
23⁵⁄₈" - 64¹⁄₈"
(60 cm - 163 cm)
Up to a 15 x 20 Room" "
Up to a 20 x 20 Room" "
Up to a 20 x 25 Room" "
Area to be cooled
Capacity needed
8,000
12,000
10,000
14,000
NOTE:Adjust BTUs to room use and location:
Shaded room reduce by 10%
Sunny room increace by 10%
For occupancy over two people add 600 BTUs per
person
Kitchen use add 4,000 BTUs
(BTUs)
Square Footage
200
300
400
500
Up to a 10 x 20 Room" "

Manual

View the manual for the Hisense AP-14DR1SFJS2 here, for free. This manual comes under the category air-conditioning and has been rated by 1 people with an average of a 5.9. This manual is available in the following languages: English. Do you have a question about the Hisense AP-14DR1SFJS2 or do you need help? Ask your question here

Need help?

Do you have a question about the Hisense and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Hisense AP-14DR1SFJS2 specifications

Below you will find the product specifications and the manual specifications of the Hisense AP-14DR1SFJS2.

General
BrandHisense
ModelAP-14DR1SFJS2
Productair-conditioning
LanguageEnglish
FiletypeUser manual (PDF)

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Hisense AP-14DR1SFJS2 below.

What does BTU stand for?

BTU stands for British Thermal Unit and is a unit used to indicate cooling power.

What does R-410A stand for?

R-410A is a refrigerant used in machines that cool to zero degrees Celsius.

How often should I clean the filters of my Hisense air conditioner?

The cleaner the filters, the better the air quality. This is why it is recommended to clean the filters of your Hisense air conditioner at least four times a year.

Is the manual of the Hisense AP-14DR1SFJS2 available in English?

Yes, the manual of the Hisense AP-14DR1SFJS2 is available in English .

Is your question not listed? Ask your question here

No results