manualHisense AP-14DR1SFJS2
turning off air conditioner before
trying to restart the air conditioner.
17

TROUBLESHOOTING

Before calling for service, try the sugge
stions below to see whether you can so
lve your problem without outside help.
Air conditioner will not operate
The power supply cord is unplugged.
Plug into a grounded
3 prong outlet. See " electrical
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING

WARNING

Requirements.”
Time-delay fuse or circuit breaker of the wrong
capacity is being used.
Replace with a time-delay fuse or circuit breaker of the
correct capacity. See " electrical
Requirements”.
The power supply cord has tripped (Reset button has
popped out).
Press and release RESET (listen for click; Reset
button will latch and remain in) to resume operation.
A household fuse has blown, or a circuit breaker has
tripped.
Replace the fuse, or reset the circuit breaker. See
“Electrical Requirements”.
The On/Off button has not been pressed.
Press ON/OFF.
The local power has failed.
Wait for power to be restored.
Air conditioner blows fuses or trips circuit breakers
Too many appliances are being used on the same circuit.
Unplug or relocate appliances that share the same circuit.
You are trying to restart the air conditioner too soon after
turning off air conditioner.
Wait at least 3 minutes after
Air conditioner runs for a short time only, but room is not
cool
Set temperature is close to room temperature.
Lower set temperature. See " portable Air Conditioner Use ”.
The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room.
Use exhaust vent fans while cooking or bathing and try not
to use heat-producing appliances during the hottest part of
the day. Portable air conditioners are designed as
supplemental cooling to local areas within a room. A higher
capacity air conditioner may be required, depending on the
size of the room being cooled.
The current air conditioner replaced an older model.
The use of more efficient components may cause the air
conditioner to run longer than an older model, but the total
energy consumption will be less. Newer air conditioners do
not emit the “ blast” of cold air you may be accustomed to
from older units, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in Btu/h) marked on the air conditioner.
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
Air conditioner power supply cord trips (Reset button
pops out)
Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord.
Press and
release RESET (listen for click; Reset button will
latch and remain in) to resume operation.
Electrical overloading, overheating, cord pinching or
aging can trip (Reset button will pop out) the power
supply cord.
After correcting the problem, press and release RESET
(listen for click; Reset button will latch and remain in) to
to resume operation. If the power cord fails to reset, contact a
service technician.
Air conditioner seems to run too much
Is there a door or window open?
Keep doors and windows
closed.
You have changed modes.
Wait at least 3 minutes after turning off air conditioner
before trying to restart the air conditioner.
Display error code
if the unit display error code E5, it is water full in the unit,
if the unit display error code E1/E2/E3/E4/EA, please contact
you should drain the water, see “Draining the air
conditioner”. After draining, you can operate the unit again.
customer service.

Manual

View the manual for the Hisense AP-14DR1SFJS2 here, for free. This manual comes under the category air-conditioning and has been rated by 1 people with an average of a 5.9. This manual is available in the following languages: English. Do you have a question about the Hisense AP-14DR1SFJS2 or do you need help? Ask your question here

Need help?

Do you have a question about the Hisense and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Hisense AP-14DR1SFJS2 specifications

Below you will find the product specifications and the manual specifications of the Hisense AP-14DR1SFJS2.

General
BrandHisense
ModelAP-14DR1SFJS2
Productair-conditioning
LanguageEnglish
FiletypeUser manual (PDF)

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Hisense AP-14DR1SFJS2 below.

What does BTU stand for?

BTU stands for British Thermal Unit and is a unit used to indicate cooling power.

What does R-410A stand for?

R-410A is a refrigerant used in machines that cool to zero degrees Celsius.

How often should I clean the filters of my Hisense air conditioner?

The cleaner the filters, the better the air quality. This is why it is recommended to clean the filters of your Hisense air conditioner at least four times a year.

Is the manual of the Hisense AP-14DR1SFJS2 available in English?

Yes, the manual of the Hisense AP-14DR1SFJS2 is available in English .

Is your question not listed? Ask your question here

No results