1. Press the MENU key to open the menu.
2. Press the E: SYSTEM CONFIGURATION soft key.
3. Press the C: SYSTEM SETUP soft key.
4. Press the B: TEST & CLEAR soft key.
5. Press the D: MEMORY CLEAR soft key.
MEMORY
CLEAR
PROCESSORUNITNO
GPSSENSORNO
NETWORKSOUNDERNO
RETURNE
EDITA
Memory clear menu
6. Use the Trackball to choose the memory to clear.
7. Press the A: EDIT soft key.
8. Use the Trackball to select YES, then press the C: ENTER soft key. One of the
following displays appears depending on the selection made at step 6.
ALL SETTNGS EXCEPT
SNDR ARE RESET TO
DEFAULT. ARE YOU SURE?
YES ... PUSH ENTER KNOB
NO ... PUSH CLEAR KEY
BEGIN COLD START
TO CLEAR GPS
MEMORY. ARE YOU SURE?
YES ... PUSH ENTER KNOB
NO ... PUSH CLEAR KEY
SOUNDER WILL BE
SET TO DEFAULT.
ARE YOU SURE?
YES ... PUSH ENTER KNOB
NO ... PUSH CLEAR KEY
Display Unit Clear GPS Receiver Clear Network Sounder Clear
Windows for clearing memory
9. Push the ENTER knob to clear the memory selected.
10. Press the MENU key to close the menu.
11. Turn the power off and on again.
Note: The message “SYSTEM HAS FAILED START UP TEST. PLEASE CONTACT A
LOCAL FURUNO REPRESENTATIVE FOR REPAIR. PUSH ANY KEY TO CONTINUE.”
may appear when powering on the display unit immediately after clearing any memory. It is
not an indication of malfunction. Press any key to continue operation.
Manual
View the manual for the Furuno 1954C-BB here, for free. This manual comes under the category marine radars and has been rated by 1 people with an average of a 9.6. This manual is available in the following languages: English. Do you have a question about the Furuno 1954C-BB or do you need help? Ask your question here