Extron SMD 202 manual

Extron SMD 202
9.2 · 1
PDF manual
 · 179 pages
English
manualExtron SMD 202

SMD202 Reset Summary

The SMD202 can be reset to default states using the rear panel reset button, the

ResetDevice page of the user interface, and SIS commands. As shown in the reset mode

summary below, each reset affects different configurations and local files, resetting some to

factory condition and retaining others.

SMD202 Reset Mode Summary

Mode Activation Result Purpose and Notes

Factory Firmware
1
Hold in the recessed rear panel

Reset button while applying

power to the unit.
The SMD202 reverts to the factory
default firmware for a single power cycle.
If incompatibility issues arise with
user-loaded firmware, use mode1
to revert to the factory default
firmware for a single power cycle.
All user files and settings are
maintained.
Reset Factory Defaults
3
Hold in the Reset button for
about 3 seconds until the Power
LED blinks once, then release
and press Reset again within 1
second*.
Mode 3:

Same as ZXXX SIS command.

Reset to defaults, but retains the IP

address and user files.
Mode 3 is useful for restoring Auto
video output rate if the display is
unable to support the currently
set rate.
Reset All IP Settings
4
Hold in the Reset button for
about 6 seconds until the Power
LED blinks twice (once at 3
seconds, again at 6 seconds).
Then, release and press Reset
again within 1 second*.
Mode 4:

Sets port mapping back to factory

default.

Sets the IP address back to factory

default (192.168.254.254).

Sets the subnet mask address back

to the factory default (255.255.0.0).

Sets the gateway IP address to the

factory default (0.0.0.0).

Turns DHCP off.

The Reset LED on the rear panel

of the unit flashes four times in
succession.
Mode 4 is used to set
IP address information using ARP
and the MAC address.
"Resetting IP Settings" appears
on a connected display.
Reset to Factory Defaults
5
Hold in the Reset button for
about 9 seconds until the Power
LED blinks three times (once at
3 seconds, again at 6 seconds,
again at 9 seconds). Then,
release and press Reset again
within 1 second*.
Mode 5:
Performs a complete reset to factory
defaults (except the firmware).

Does everything mode 4 does.

Clears port configurations.

Resets all IP options.

Clears all user settings.

Clears all files from the unit.

The Reset LED on the rear panel

of the unit flashes four times in
succession.
Mode 5 is useful when wanting to
start over with configuration and
uploading, and also to replace
events.
"Resetting SMD202" appears on
a connected display.

NOTES:

*

= For modes 3, 4, and 5, nothing happens if the momentary press does not occur within 1 second.

Although removable devices and network shares are accessible as part of the user file system, those

temporarily mounted file systems are not affected by reset operations. A mode 1, 3, 4, and 5 reset does

not un-mount removable devices. If required, those devices must be unmounted manually.

SMD202 • Reference Information 153

Manual

View the manual for the Extron SMD 202 here, for free. This manual comes under the category digital decoder and has been rated by 1 people with an average of a 9.2. This manual is available in the following languages: English. Do you have a question about the Extron SMD 202 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron SMD 202 specifications

Below you will find the product specifications and the manual specifications of the Extron SMD 202.

General
BrandExtron
ModelSMD 202 | 60-1306-01
Productdigital decoder
LanguageEnglish
FiletypeUser manual (PDF)
Performance
Channels quantity- channels
Maximum video resolution1920 x 1200 pixels
Network
Ethernet interface typeGigabit Ethernet
Ethernet LAN data rates10,100,1000 Mbit/s
Cabling technology10/100/1000BaseE-T(X)
Ports & interfaces
Number of HDMI outputs1
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports1
RS-232 ports1
Power
AC adapter input voltage100-240 V
AC adapter frequency50/60 Hz
Power consumption (max)15.8 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Storage temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width222 mm
Depth152 mm
Height25 mm
Weight500 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron SMD 202 below.

What is the weight of the Extron SMD 202?

The Extron SMD 202 has a weight of 500 g.

What is the height of the Extron SMD 202?

The Extron SMD 202 has a height of 25 mm.

What is the width of the Extron SMD 202?

The Extron SMD 202 has a width of 222 mm.

What is the depth of the Extron SMD 202?

The Extron SMD 202 has a depth of 152 mm.

Is the manual of the Extron SMD 202 available in English?

Yes, the manual of the Extron SMD 202 is available in English .

Is your question not listed? Ask your question here

No results