Command and Response Table for SIS Commands

Command
ASCII Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Button Selection
Trigger a button
E
B*
X!
BTNO
}
BtnoB*
X!
]
Execute the commands
programmed to button
X!
. (This
command produces the same
results as pressing button
X!
on
the front panel).
X!
= 01, 02, 03, 04, 05, or 06
NOTE: Use the MLC 55, 62 and 64 Series Configuration Program to configure the buttons with commands.
Example
E
B*5BTNO
}
BtnoB*05
]
Perform commands assigned to
button 5.
Button LED State
Set button LED state
51 *
X!
*
X@
*
X#
#
Lmp
X!
*
X@
*
X#
]
Set LED state of button
X!
to
X@
and its LED color to
X#
.
X!
= 01 through 06.
For
X@
:
0 = off 3 = slow blink
1 = dim 4 = fast blink
2 = on (bright)
For
X#
:
1 = white
2 = red
View LED status
E
51 *
X!
#
} X@
*
X@
]
View the red and white LED
states of button
X!
.
NOTE: In the response, the first
X@
is the white LED state. The second
X@
is the red LED state.
Discrete Audio Volume Adjustment on Devices with Volume Tables (Non-VC Models)
Set volume level
X$
V Vol
X$
]
Set volume table level to
X$
.
X$
is the volume step number to
which the volume is being set
(varying with the device volume
table). It can be up to 3 digits
with leading zeros optional.
NOTE: Only positive values are allowed. Volume table levels start with 0 (zero). Setting a discrete volume level that is
outside of the volume table range results in an E13 error response.
Increment volume level
+V
Vol
X$
]
Increase the volume by one
volume table increment.
X$
= current volume level.
Decrement volume level
–V
Vol
X$
]
Decrease the volume by one
volume table increment.
View current volume level
V
X$
]
Display the current volume level.
Increase and Decrease Audio Volume on Devices without Volume Tables (Non-VC Models Only)
NOTE: Attempts to enter an
X$
V (Set volume level) command to set a discrete volume level on a device whose driver
does not include a volume table result in an E14 error response.
Increment volume level
+V Vol+
Increase the volume level by
one step.
Decrement volume level
–V Vol–
Decrease the volume level by
one step.
View volume level
V — — —
The response is three dashes.
MLC 55 Series MediaLink Controllers • SIS Control 45

Manual

View the manual for the Extron RS-232 and IR Control here, for free. This manual comes under the category remote controllers and has been rated by 1 people with an average of a 7.8. This manual is available in the following languages: English. Do you have a question about the Extron RS-232 and IR Control or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron RS-232 and IR Control specifications

Below you will find the product specifications and the manual specifications of the Extron RS-232 and IR Control.

General
BrandExtron
ModelRS-232 and IR Control | 60-1390-03
Productremote controller
EAN5712505902448
LanguageEnglish
FiletypeUser manual (PDF)
Design
InterfaceIR Wireless/Wired
Product colorWhite
Remote control proper useAV switch
Input typePress buttons
Backlight buttonsYes
Display
Built-in displayNo
Performance
Number of devices supported-
Maximum range- m
Battery
RechargeableNo
Built-in batteryNo
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (transmitter) (max)1.1 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Operating temperature (T-T)32 - 122 °F
Storage temperature (T-T)-40 - 70 °C
Storage temperature (T-T)-40 - 158 °F
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width44.7 mm
Depth35.8 mm
Height71.4 mm
Weight100 g
Packaging data
Package width187 mm
Package depth264 mm
Package height76 mm
Package weight790 g
Logistics data
Harmonized System (HS) code85299097
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron RS-232 and IR Control below.

What is the weight of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a weight of 100 g.

A battery in my remote controller has started to corrode. Is the device still safe to use?

The product can still be used safely after proper cleaning. Remove the battery with gloves and clean the battery compartment with a toothbrush and vinegar. After drying, new batteries can be inserted into the device.

What is the height of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a height of 71.4 mm.

What is the width of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a width of 44.7 mm.

What is the depth of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a depth of 35.8 mm.

Is the manual of the Extron RS-232 and IR Control available in English?

Yes, the manual of the Extron RS-232 and IR Control is available in English .

Is your question not listed? Ask your question here

No results