The configuration program main window consists of two major sections (see
figure 32 on the previous page):
1
Device configuration tree — Displays a list of devices that have been
configured and lets you organize and save all configurations in a single project file.
2
Main panel — Contains the controls that enable you to configure the MLC.
The following is displayed on the MLC main window:
The device configuration name appears in the configuration tree (see
figure 32,
1
), with the names of the two ports to which a device can be
connected and controlled via RS-232 or IR: Port A (RS-232) and Port B (IR).
The Front Panel screen appears in the main panel (
2
) and contains a diagram
representing the front panel of your selected MLC, along with other controls for
the MLC front panel. (If this screen appears blank when the window is opened,
click on the name of the MLC device configuration in the left panel to display it.)
In the title bar, the project name is shown as “Unnamed Project*.” (The asterisk
following the name indicates that the project has not been saved since changes
were made.)
Three tabs provide access to controls that you will use to configure the MLC 55
(see the configuration program help file for explanations of their contents):
Front Panel — Configure the front panel buttons and assign all commands
to them.
Port Configuration — Select and configure the port to which the display
device or switcher will be connected.
Advanced Configuration — Adjust parameters for inactivity periods,
powering on and off, and volume adjustment.
7. Save and name a project as follows:
a. From the File menu, select Save As... .
b. In the Save As dialog box, give your project file a name and save it to the desired
location on your computer.
NOTE: Your project is saved as a file with the extension .mlp.
You are now ready to create configurations for your MLC device by specifying parameters
for its ports and buttons (see the configuration program help file for procedures).

Accessing the Help File

For instructions on creating configurations using the program, see the MLC 55, 62
and 64 Series Configuration Program Help File. You can access the help file when the
configuration program is open using any of the following methods:
From the Help menu, select MLC 55, 62 and 64 Series Configuration Program
Help.
Figure 33. Configuration Program Help Menu
MLC 55 Series MediaLink Controllers • Software-based Configuration 33

Manual

View the manual for the Extron RS-232 and IR Control here, for free. This manual comes under the category remote controllers and has been rated by 1 people with an average of a 7.8. This manual is available in the following languages: English. Do you have a question about the Extron RS-232 and IR Control or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron RS-232 and IR Control specifications

Below you will find the product specifications and the manual specifications of the Extron RS-232 and IR Control.

General
BrandExtron
ModelRS-232 and IR Control | 60-1390-03
Productremote controller
EAN5712505902448
LanguageEnglish
FiletypeUser manual (PDF)
Design
InterfaceIR Wireless/Wired
Product colorWhite
Remote control proper useAV switch
Input typePress buttons
Backlight buttonsYes
Display
Built-in displayNo
Performance
Number of devices supported-
Maximum range- m
Battery
RechargeableNo
Built-in batteryNo
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (transmitter) (max)1.1 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Operating temperature (T-T)32 - 122 °F
Storage temperature (T-T)-40 - 70 °C
Storage temperature (T-T)-40 - 158 °F
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width44.7 mm
Depth35.8 mm
Height71.4 mm
Weight100 g
Packaging data
Package width187 mm
Package depth264 mm
Package height76 mm
Package weight790 g
Logistics data
Harmonized System (HS) code85299097
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron RS-232 and IR Control below.

What is the weight of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a weight of 100 g.

A battery in my remote controller has started to corrode. Is the device still safe to use?

The product can still be used safely after proper cleaning. Remove the battery with gloves and clean the battery compartment with a toothbrush and vinegar. After drying, new batteries can be inserted into the device.

What is the height of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a height of 71.4 mm.

What is the width of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a width of 44.7 mm.

What is the depth of the Extron RS-232 and IR Control?

The Extron RS-232 and IR Control has a depth of 35.8 mm.

Is the manual of the Extron RS-232 and IR Control available in English?

Yes, the manual of the Extron RS-232 and IR Control is available in English .

Is your question not listed? Ask your question here

No results