Configuring a Macro

1. Click Tools > Configure Macros. The Configure Macros dialog box opens.
2. Select an empty macro slot from the Select Macro drop-down.
3. From the Destination drop-down, select a destination for the macro action. Choose
Local for the local DMP 128 Plus, or Add Destination... for a remote destination. If
choosing Local, proceed to step 4.
NOTE: Macro commands can only be sent to remote destinations via the
LAN/VoIP1 port (V models only).
a. After selecting Add Destination..., the Edit Remote Destinations dialog
box opens.
b. Complete the form in the dialog box, including username and password, if required.
c. Select Apply to add the device to the drop-down in the Destinations column.
d. Click Close to close the Edit Remote Destinations dialog box.
e. Select the newly created remote destination from the Destination drop-down.
4. From the Action drop-down, select an action to be configured.
Recall Preset — Recall an existing preset.
Set Group Gain — Set the level of an existing gain group.
Group Gain Inc/Dec — Set the increment/decrement values of an existing gain
group.
Set Group Mute — Mute or unmute an existing mute group.
Gain — Set the gain of a specific gain block on a specific channel.
Mute — Mute or unmute a specific gain block on a specific channel.
Set Phantom Power – Enable or disable phantom power on a specific
Mic/Line input channel.
Meters On/Off — Enable or disable level meters at the input gain or output
attenuation stages of a specific channel.
Start Player — Starts a selected player.
Stop Player — Stops a selected player.
SIS Command — Type in a single SIS command to perform an action not listed
above (see Remote Communication and Control on page123).
NOTE: Use the W key in place of E and the | (pipe) key in place of }.
Set Input Format — Specify whether mic/line inputs receive analog signal from the
inputs or digital signal via the Dante network (see
9
in figure 45 on page25).
Dial Number — Use a specific VoIP line to dial a string.
Dial Digits — Use a specific VoIP line and line appearance to dial a predetermined
number, such as an extronsion number or conference pin.
End Call — End calls on a specific line or all appearances of a VoIP line.
5. Once the action is chosen, up to four additional selections are made available. These
additional selections must be completed in order to proceed to the next macro step.
For example, if Set Group Gain is the selected action, Selection 1 prompts the
selection of a gain group to be affected and Selection 2 determines the gain level of
the selected group.
6. When all of the action selections are configured, a new line appears at the bottom of the
form so another action can be configured.

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results