Macros

Macros are sets of actions that can affect the local DMP 128 Plus and other Extron
products on the same TCP/IP network. They can be configured in Emulate or Live mode
via an Ethernet connection only, and they can be saved to a configuration file or pushed
to DMP128 Plus internal memory. Macros are comprised of up to 32 actions that occur in
sequence to quickly configure a system for specific applications.
Figure 141. Configure Macros Dialog Box
1
Select Macro Drop-Down — Select an empty macro slot to configure or select an
existing macro to edit from this drop-down menu.
2
Change Name Button — Click this button to enter a new name for a previously
configured macro. Press <Enter> to confirm the macro name change.
3
Macro Configuration Form — Up to 32 actions can be configured in this form. When
one action is configured, a new line appears to configure the next action in the macro.
4
Delete Current Macro Button — Deletes the macro currently selected from the
Select Macro drop-down.
5
Clone Macro Button — Clones the currently selected macro to a new macro slot.
6
Run Macro Button — Runs the macro currently selected from Select Macro
drop-down, performing all of the configured actions in sequential order. This is only
available when connected to a DMP 128 Plus in Live mode via the LAN or VOIP 1 port.
7
Edit Remote Destinations Button — Opens the dialog box to edit data for remote
devices being configured by the actions in a macro. Remote devices in the network
can also be added from this dialog box (see the Configure Macros topic in the
DSPConfigurator Help file). This is only available when connected in Live mode.
8
Push Macros to Device Button — Pushes all macros to a connected DMP128Plus.
Once the macros are on the device, they can be run by control systems or
DSPConfigurator. This button is only available when connected Live to a DMP 128 Plus
(see Live and Emulate Panel on page18).
9
Power-on Macro Drop-Down — Select an existing macro to run whenever the
DMP128Plus is powered on.
¢
Close Button — Closes the Configure Macros dialog box, retaining macros that
have been created or edited. Actions that have not been completely configured show a
symbol to the left of the Destination field in the macro configuration form. Actions
showing the symbol are not saved when the dialog box is closed.
figure 141. Configure Macros Dialog Box

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results