DMP 128 Plus • DSP Configurator Software 62

Output Dynamics Block

One dynamics block is available for each output channel. This block functions the same

as the mic/line input dynamics block (see Input Dynamics Blocks on page32 for

information on configuring the output dynamics block).

Output Attenuation Block

Double-click the output Attenuation block to open the Attenuation dialog box.

Figure 106. Output Attenuation Block

The Attenuation dialog box provides attenuation control for the selected output.

Figure 107. Attenuation Dialog Box

1
Output NameThis name changes to match the default or user defined output name.
2

Output Attenuation Fader — Click and drag the trim fader to provide up to 100dB

of attenuation. Click the trim fader and use the <Up Arrow> or <Down Arrow> to adjust

the fader up or down in 1 dB steps.

3
Output Attenuation Text Box — Allows the user to enter a gain or attenuation value in

0.1 dB steps.

4

dBFS Meter — Provides post-attenuation and pre-mute a readout of the output signal

level.

5
dBFS Text Readout — Displays a numerical readout of the output signal level.
6

Polarity Button — Click this button to invert the signal polarity of the selected output.

When the button displays the black + symbol on a gray field ( ), the polarity is normal.

When the button displays the black - symbol on a yellow field ( ), the polarity is

inverted.

figure 106. Output Attenuation Block

figure 107. Output Attenuation Dialog Box

1

Output Name

6

Polarity Button

2

Output Attenuation Fader

7

Mute Button

3

Output Attenuation Text Box

8

OK Button

4

dBFS Meter

9

Cancel Button

5

dBFS Text Readout

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .