DMP 128 Plus • DSP Configurator Software 54

Renaming an Expansion or AT Input

NOTES:
AT inputs only appear on DMP 128 Plus AT models.
AT inputs can only be renamed when connected in Live mode. Default input names
appear in Emulate mode.
Renaming an AT input in DSP Configurator affects the receiver name in
DanteController. Alternatively, renaming a receiver channel name in Dante Controller
affects the name displayed in DSPConfigurator (see Renaming a Receiver or
Transmitter on page113).
1. Click the expansion or AT input name field.
Figure 89. Expansion Input Name Field
2. Delete or highlight the text and type the desired name.
Figure 90. New Expansion Input Name
3. Press the <Enter> key or navigate away from the field to confirm and apply the new
name. Press the <Down Arrow> key to navigate to and highlight the next name field.
Figure 91. Renamed Expansion
NOTE: Follow the same procedure to edit an Expansion Input name.

Expansion and AT Inputs Overview

With the Extron Expansion Port (EXP), two EXP enabled devices can be connected for
bidirectional communication of 16 audio channels. When two units are connected, one
unit must be set as the Primary Unit and the other must be set as the Secondary Unit (see
Expansion Bus on page94). This synchronizes the sampling clocks of the two units.
AT inputs allow a DMP 128 Plus AT model to receive signal from the audio network.
Network audio routing is done with Dante Controller (see Dante Controller on page107).
Figure 92. Expansion Bus Panel with AT and Expansion Inputs
figure 89. Expansion Input Name Field
figure 90. New Expansion Input Name
figure 91. Renamed Expansion
figure 92. Expansion Inputs Panel

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results