Extron DMP 128 Plus C manual

Extron DMP 128 Plus C
8.4 · 1
PDF manual
 · 188 pages
English
manualExtron DMP 128 Plus C
DMP 128 Plus • DSP Configurator Software 43
6
Cancel Button — Reverts any changes made to the contained parameters back to
their states when the current instance of the Pre-mixer Gain dialog box was opened
and closes the dialog box.
7
Pre-mixer Gain Help Button — Opens the Pre-mixer Gain topic of the
DSPConfiguratorHelp file for further assistance in understanding operating the
Pre-mixer Gain dialog.

Aux Inputs

Eight Aux inputs are available with processing. These inputs can be assigned as one of the
following:
Player inputs that play audio files stored in the DMP 128 Plus internal memory (see
Player Input on the next page)
USB inputs that receive audio via the rear panel USB audio port (see USB Input on
page45)
VoIP lines for use with a VoIP network (V models only, see VoIP Input on page45)
Figure 72. Aux Inputs Panel

Renaming an Aux Input

1. Click the input name field.
Figure 73. Aux Input Name Field
2. Delete or highlight the text and type the desired name.
Figure 74. New Aux Input Name
3. Press the <Enter> key or navigate away from the field to confirm and apply the new
name. Press the <Down Arrow> key to navigate to and highlight the next name field.
Figure 75. Renamed Aux Input
NOTE: Follow the same procedure to edit an Aux input name.
figure 72. Aux Inputs Panel
figure 73. Aux Input Name Field
figure 74. New Aux Input Name
figure 75. Renamed Aux Input

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results