DMP 128 Plus • DSP Configurator Software 40

Adaptive Gain

After inserting an adaptive gain processor, double-click the AG icon to open the
Adaptive Gain dialog box.
Figure 67. Adaptive Gain Dialog Box
1
Adaptive Gain Source Configuration — In the Add Gain To column, check the
inputs that will have gain added by the adaptive gain processor. In the Max Gain
(dB) column, enter the maximum amount of gain that will be applied to each channel
selected in the Add Gain To column. When a box is checked, gain is applied to that
channel when signal exceeds the threshold on the adaptive gain trigger channel.
NOTE: For every 1 dB of signal beyond the level set in the Threshold field, 1 dB
of gain will be added to the channels selected in the Add Gain To column. This
occurs until the maximum gain set in the Max Gain (dB) field has been applied.
2
Adaptive Gain Parameter Settings — Contains controls for Threshold, Attack
Time, Hold Time, and Release Time.
3
Adaptive Gain Operation Help Button — Opens the Adaptive Gain Operation
topic of the DSPConfiguratorHelp file for further assistance in adaptive gain
configuration.

Input Automix Block

Double-click the Automix block to open a drop-down menu. Select Auto-mixer to insert
the automix processor into the block.
Figure 68. Automix Block and Drop-Down
Once the automix processor is inserted into the Automix block, double-click the block to
open the Automix dialog box.
1
Adaptive Gain Source Configuration
2
Adaptive Gain Parameter Settings
3
Adaptive Gain Operation Help Button
figure 67. Adaptive Gain Dialog Box
figure 68. Automix Block and Drop Down

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results