DMP 128 Plus • Remote Control and Configuration 129

Command and Response Table Sections

Command and Response Table for Basic SIS Commands

Command ASCII command
(host to device)
Response
(device to host)
Additional description
Information requests
General information
I
VnnXnnA12x08
E16x16]
Response will vary
depending on model.
Model name
1I
DMP 128 Plus]
Response varies
depending on model.
Model description
2I Digital audio
matrix processor]
Response will vary
depending on model.
System memory usage
3I <number> Bytes Used
out of <number>
KBytes]
User memory usage
4I <number> Bytes Used
out of <number>
KBytes]
Query firmware version
Q
{version x.xx}]
Query firmware version
with build
*Q
{version x.xx.xxxx)]
Query kernel/library
version
**Q
{version x.xx.xxxxLX)]
Query firmware version
(advanced)
X4% Q {specific version info}] See X4% below.
Query part number
N
zz-zzzz-zz]
Ethernet Data Port
Set current connected
port timeout
E0*X2^TC} Pti0*X2^]
View current connected
port timeout

E 0TC} X2^]

Set global IP port
timeout

E1*X2^TC} Pti1*X2^]

View global IP port
timeout

E1TC} X2^]

KEY:
X2^
= IP Timeout The number of seconds before timeout on IP connections (min=1,
max= 65000 and default = 30 (300 seconds)
X4%
= Firmware Query
0 = Detailed version information (includes all 2Q, 3Q, and 4Q)
1 = Firmware version
2 = Final stage bootloader
3 = Factory base code version
4 = Updated firmware version

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results