Dante Troubleshooting

The most common Dante troubleshooting issues occur when devices are not discovered by
Dante Controller or when routing is not successful. Both issues occur when software is not
able to properly discover devices operating on the Dante network.
Before moving into more difficult troubleshooting, shut down Dante Controller and reseat the
Ethernet cable connecting the PC to the Dante network and restart Dante Controller. This
can be enough for the software to reacquire the Dante network.
If the problem persists, perform the following troubleshooting procedures in the order listed.

Simplifying the Network for Troubleshooting

If further troubleshooting of Dante Controller is necessary, begin by simplifying the network:
1. Bypass network switches by connecting two Dante-compatible units, such as a
DMP128 PlusAT and an AXI44AT, via their AT ports.
2. Connect the PC to an unused AT port with an Ethernet cable.
3. Use Dante Controller to check if the issue was resolved before moving on to network
interface troubleshooting.
4. If the issue is resolved, add connections and hardware one at a time, checking for
proper operation after each addition, until the point of failure is discovered (typically a
bad cable or invalid redundant configuration).

Troubleshooting the Network Interface

If the issue is still present, continue to diagnose the PC network connections as described
below. Check Dante Controller after each step to see if the problem is resolved.
1. Click the Choose a Dante Interface icon (see figure 193,
1
below). The Configure
Dante Interfaces dialog box opens.
Figure 193. Choose a Dante Interface Icon
figure 193 Choose a Dante Interface Icon

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results