DMP 128 Plus • Dante Controller 118
To configure the DMP 128 Plus AT in redundant mode using DSP Configurator:
1. Use DSP Configurator to connect to the DMP 128 Plus AT in Live mode (see Live and
Emulate Panel on page18).
2. Select Tools > Device Settings.
3. In the Device Settings dialog box, use the right navigation arrow ( ) to navigate to
and select the Dante Device tab (see figure 191,
1
below).
4. Select Enable Redundant Mode (
2
).
5. Select DHCP or Static IP and enter a valid redundancy network configuration (
3
).
6. Click Apply (
4
).
Figure 191. Redundant Mode Configuration in DSP Configurator

Dante Controller Operation

Dante Transmitters and Receivers

A Dante network is comprised of transmitters that output digital audio onto the Dante
network and receivers that receive digital audio input from the Dante network.
Transmitters output digital audio from the device onto the audio network.
Receivers take in digital audio from the audio network into the device.
DMP 128 Plus AT Transmitters and Receivers
In the DMP 128 Plus AT, the line output and EXP output channels are Dante transmitters
because their audio output is transmitted onto the Dante network. Routing an analog
output to the Dante network allows the signal to be output on both analog and Dante
simultaneously, the same is true for the EXP outputs.
The DMP 128 Plus AT EXP input channels are Dante receivers because they receive digital
audio signal from the Dante network that can then be routed and mixed into the
DMP 128 Plus AT mix matrix.
figure 191 Redundant Mode DSPC

Manual

View the manual for the Extron DMP 128 Plus C here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. This manual is available in the following languages: English. Do you have a question about the Extron DMP 128 Plus C or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron DMP 128 Plus C specifications

Below you will find the product specifications and the manual specifications of the Extron DMP 128 Plus C.

General
BrandExtron
ModelDMP 128 Plus C | 60-1512-01
Productnot categorized
EAN5711783372820
LanguageEnglish
FiletypeUser manual (PDF)
Ports & interfaces
Number of inputs12 inputs
Features
Total Harmonic Distortion plus Noise (THD+N)0.01 %
Frequency range20 - 20000 Hz
Signal-to-Noise Ratio (SNR)115 dB
Input impedance10000 Ω
Housing colorGray
Housing materialMetal
Power
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)29.4 W
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Weight & dimensions
Width442 mm
Depth241 mm
Height43 mm
Weight2040 g
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron DMP 128 Plus C below.

What is the weight of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a weight of 2040 g.

What is the height of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a height of 43 mm.

What is the width of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a width of 442 mm.

What is the depth of the Extron DMP 128 Plus C?

The Extron DMP 128 Plus C has a depth of 241 mm.

Is the manual of the Extron DMP 128 Plus C available in English?

Yes, the manual of the Extron DMP 128 Plus C is available in English .

Is your question not listed? Ask your question here

No results