AXI 22 AT and AXI 44 AT • Remote Control 35

Command and Response Table for SIS Commands

Command ASCII Command
(hostto unit)
Response
(unit to host)
Additional Description
General
Query part number
N
PnoX!]
Query firmware version
Q
Ver01*X@]
Query firmware version
with patch
*Q
Bld*X@]
Query detailed firmware
version
0Q
Ver00*X1#]
Query embedded OS
type and version
14Q Ver14*{embedded OS
version}]
Query firmware version
with build
20Q Ver20*x.xx.xxxxx-
bxxx]
major.minor.patch-
build
Set Verbose Mode

EX1$ CV} VrbX1$]

View Verbose Mode

ECV } VrbX1$]

Reboot Dante device

EB EXPD } ExpdB]

Reboots only the Dante
interface. AXI device
remains on during Dante
reboot.
Query current status

EK EXPD } ExpdKX1^]

System reset
(factorydefault)

EZXXX} Zpx]

Resets gain, phantom
power, executive mode,
and preset configuration.
Network configuration is
not affected.
Network Commands
Set DHCP on

ED1 EXPD } ExpdD1]

DHCP must be off in order
for this command to be
accepted as valid (DHCP is
enabled by default).
View DHCP status

ED EXPD } ExpdDX1%]

Set Dante IP/subnet/
gateway
EI X#* X$* X% EXPD} ExpdIX#*X$*X%]
Using this command
automatically turns DHCP
off. Dante device must
be rebooted for new IP
configuration to take effect
(see the Reboot Dante
device command in the
section above).
View IP/subnet/gateway
EI EXPD } ExpdIX#*X$*X%]
View MAC address

EH EXPD } ExpdHX^]

View Dante device
name

EN EXPD } ExpdNX&]

NOTE: All variables used on this page are defined on the next page.

Manual

View the manual for the Extron AXI 44 AT here, for free. This manual comes under the category audio / video converters and has been rated by 1 people with an average of a 9.2. This manual is available in the following languages: English. Do you have a question about the Extron AXI 44 AT or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron AXI 44 AT specifications

Below you will find the product specifications and the manual specifications of the Extron AXI 44 AT.

General
BrandExtron
ModelAXI 44 AT | 60-1628-01
Productaudio / video converter
LanguageEnglish
FiletypeUser manual (PDF)
Outputs
Audio (L/R) out0
Inputs
USB 1.1 ports quantity0
Digital audio coaxial in0
Digital audio optical in0
Technical details
Product colorBlack
CertificationCE, c-UL, UL, C-Tick, FCC A, ICES, VCCI A
Product colorBlack
CertificationCE, c-UL, UL, C-Tick, FCC A, ICES, VCCI A
Packaging data
Quantity1
Weight & dimensions
Height43 mm
Width110 mm
Depth153 mm
Weight300 g
Height43 mm
Width110 mm
Depth153 mm
Weight300 g
Power
Power consumption (typical)11.9 W
Power consumption (typical)11.9 W
Ports & interfaces
Audio (L/R) out0
Audio output-
Audio input-
Audio
Audio input channels4 channels
Audio output channels4 channels
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Heat dissipation25.1 BTU/h
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron AXI 44 AT below.

What is the weight of the Extron AXI 44 AT?

The Extron AXI 44 AT has a weight of 300 g.

What certifications does the Extron AXI 44 AT have?

The Extron AXI 44 AT has the following certifications: CE, c-UL, UL, C-Tick, FCC A, ICES, VCCI A.

What is the height of the Extron AXI 44 AT?

The Extron AXI 44 AT has a height of 43 mm.

What is the width of the Extron AXI 44 AT?

The Extron AXI 44 AT has a width of 110 mm.

What is the depth of the Extron AXI 44 AT?

The Extron AXI 44 AT has a depth of 153 mm.

Is the manual of the Extron AXI 44 AT available in English?

Yes, the manual of the Extron AXI 44 AT is available in English .

Is your question not listed? Ask your question here

No results