Extron AXI 44 AT manual

Extron AXI 44 AT
9.2 · 1
PDF manual
 · 45 pages
English
manualExtron AXI 44 AT
AXI 22 AT and AXI 44 AT • Dante Controller 31

Disconnecting Inputs from Outputs

To remove a subscription, click the intersection between the receiver and the transmitter
again.
NOTE: After making changes to Dante network routing such as connections
(subscriptions), device names, or channel labels, wait at least 5 seconds before
disconnecting or powering down the devices. This ensures that the new information
is properly saved to those devices. Device level configuration such as sample rates,
latency, and clock settings are saved instantly.

Dante Troubleshooting

The most common Dante troubleshooting issues occur when devices are not discovered by
the Dante Controller software, or routing is not successful. Both issues occur when software
is not able to properly discover devices operating on the Dante network.
Before moving into more difficult troubleshooting, shut down Dante Controller and reseat the
Ethernet cable connecting the host PC to the Dante network and restart Dante Controller.
This can be enough for the software to reacquire the Dante network.
If the problem persists, perform the following troubleshooting procedures in the order
presented.

Simplifying the Network for Troubleshooting

If further troubleshooting of Dante discovery is necessary, begin by simplifying the network:
1. Bypass network switches by connecting two Dante-compatible units, such as an
AXIand a DMP128 PlusAT, via their AT ports.
2. Connect the PC to an unused AT port with an Ethernet cable.
3. Use Dante Controller to check if the issue was resolved before moving on to network
interface troubleshooting.
4. If the issue is resolved, add connections and hardware one at a time, checking for
proper operation after each addition, until the point of failure is discovered (typically a
bad cable or invalid redundant configuration).

Troubleshooting the Network Interface

If the issue is still present, continue to diagnose the PC network connections as described
below. Check Dante Controller after each step to see if the problem is resolved.
1. Open the Configure Dante Interface dialog box by clicking the Choose a Dante
Interface icon (see figure 34,
1
).
Figure 34. Choose a Dante Interface Icon
Be certain the correct LAN connection is selected (the PC LAN port that is physically
connected to the Dante network) and note the IP address.
figure 34 Choose a Dante Interface Icon

Manual

View the manual for the Extron AXI 44 AT here, for free. This manual comes under the category audio / video converters and has been rated by 1 people with an average of a 9.2. This manual is available in the following languages: English. Do you have a question about the Extron AXI 44 AT or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Extron and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Extron AXI 44 AT specifications

Below you will find the product specifications and the manual specifications of the Extron AXI 44 AT.

General
BrandExtron
ModelAXI 44 AT | 60-1628-01
Productaudio / video converter
LanguageEnglish
FiletypeUser manual (PDF)
Outputs
Audio (L/R) out0
Inputs
USB 1.1 ports quantity0
Digital audio coaxial in0
Digital audio optical in0
Technical details
Product colorBlack
CertificationCE, c-UL, UL, C-Tick, FCC A, ICES, VCCI A
Product colorBlack
CertificationCE, c-UL, UL, C-Tick, FCC A, ICES, VCCI A
Packaging data
Quantity1
Weight & dimensions
Height43 mm
Width110 mm
Depth153 mm
Weight300 g
Height43 mm
Width110 mm
Depth153 mm
Weight300 g
Power
Power consumption (typical)11.9 W
Power consumption (typical)11.9 W
Ports & interfaces
Audio (L/R) out0
Audio output-
Audio input-
Audio
Audio input channels4 channels
Audio output channels4 channels
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Storage relative humidity (H-H)10 - 90 %
Heat dissipation25.1 BTU/h
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Extron AXI 44 AT below.

What is the weight of the Extron AXI 44 AT?

The Extron AXI 44 AT has a weight of 300 g.

What certifications does the Extron AXI 44 AT have?

The Extron AXI 44 AT has the following certifications: CE, c-UL, UL, C-Tick, FCC A, ICES, VCCI A.

What is the height of the Extron AXI 44 AT?

The Extron AXI 44 AT has a height of 43 mm.

What is the width of the Extron AXI 44 AT?

The Extron AXI 44 AT has a width of 110 mm.

What is the depth of the Extron AXI 44 AT?

The Extron AXI 44 AT has a depth of 153 mm.

Is the manual of the Extron AXI 44 AT available in English?

Yes, the manual of the Extron AXI 44 AT is available in English .

Is your question not listed? Ask your question here

No results