Electrolux EXI09HD1WI manual

Electrolux EXI09HD1WI
9.5 · 1
PDF manual
 · 124 pages
English
manualElectrolux EXI09HD1WI
39

2SHUDWLRQ7LSV

environment that has a high relative humidity.
 A white mist may generate due to moisture
generated from defrosting process when the air
conditioner restarts in HEAT mode operation after
defrosting.
/RZQRLVHRIWKHDLUFRQGLWLRQHU
 You may hear a low hissing sound when the
compressor is running or has just stop running.
7KLVLVWKHVRXQGRIWKHUHIULJHUDQWÀRZLQJRU
coming to a stop.
 You also may hear a low “squeak” sound when
the compressor is running or just stopped
running. This is caused by heat expansion and
cold contraction of the plastic parts in the unit
when the temperature is changing.
 A noise may be heard due to louver restoring to
its original position when power is furst turned on.
'XVWLVEORZQRXWIURPWKHLQGRRUXQLW
This is a normal condition when the air conditioner
KDVQRWEHHQXVHGIRUDORQJWLPHRUGXULQJ¿UVWXVH
of the unit.
$SHFXOLDUVPHOOFRPHVRXWIURPWKHLQGRRUXQLW
This is caused by the indoor unit giving off smells
permeated from building material, furniture or
smoke.
7KHDLUFRQGLWLRQHUWXUQHVWR)$1RQO\PRGH
IURP&22/RU+($7PRGH
When the indoor temperature reaches the setting
value, the compressor will stop automatically, and
the air conditioner turns to FAN mode.
The compressor will start again when the indoor
temperature rises in COOL mode or falls in HEAT
mode to the set point.
&RQGHQVDWLRQ
Condensate water is likely to form at the air outlet
if cooling or drying for a long time when the relative
humidity is more than 80% (with doors and windows
open).
Set the vertical louver to its maximum angle (to
WKHÀRRUDQG+LJKIDQVSHHG&ORVHWKHGRRUVDQG
windows.
Lighting or a car wireless telephone operating
nearby may cause the unit to malfunction.
Disconnect the unit with power and then re-connect
the unit with power again. Push ON/OFF button on
the remote control to restart operation.
;)DQIXQFWLRQ
The indoor unit may keep running after you switch
off the unit by pressing ON/OFF button.
Please check whether the X-Fan function is
switched off.
The following events may occur during normal
operation:
3URWHFWLRQRIWKHDLUFRQGLWLRQHU
 &RPSUHVVRUSURWHFWLRQ
The compressor can’t restart for 3 minutes
after it stops
 $QWLIUHH]LQJ
If the unit is operating in COOL mode and
in low ambient temperature, frost may be
formed on the heat exchanger. When indoor
heat exchanger temperature decreases
below 0°C, the compressor will stop
operation to protect the unit.
 'HIURVWLQJ
Frost may form on the outdoor unit in heating
operation when the outdoor temperature
is low but humidity is high, resulting in low
KHDWLQJHI¿FLHQF\
During this condition the air conditioner will
stop heating operation and start defrosting
automatically. The time to defrost may vary
from 3 to 12 minutes.
During defrosting, the fan motors of indoor
unit and outdoor unit will stop, the indoor
LQGLFDWRUÀDVKHV³+´DQGWKHRXWGRRUXQLW
may emit vapor. This is not malfunction. After
GHIURVWLQJLV¿QLVKHGWKHKHDWLQJRSHUDWLRQ
will recover automatically.
 $QWLFROGDLU
In HEAT mode, the indoor fan will not operate
in order to prevent cold air being blown into
the room (within 5 minutes), if the indoor
heat exchanger does not reach a minimum
temperature under the following states:
(1) Heating operation just start.
$IWHUDXWRGHIURVWLQJLVMXVW¿QLVKHG
(3) Heating at low temperature.
*HQWOHEUHH]H
The indoor unit may blow gentle breeze and the
louver rotate to a certain position in the following
situation:
(1) In HEAT mode, the unit is turned on, the
compressor does not reach the starting
condition.
(2) In HEAT mode, the temperature reaches the
set value and the compressor stops running
for about 1 minute.
$ZKLWHPLVWFRPLQJRXWIURPWKHLQGRRUXQLW
 A white mist may generate due to a large
temperature difference between air inlet
and air outlet in COOL mode in an indoor

Manual

View the manual for the Electrolux EXI09HD1WI here, for free. This manual comes under the category air-conditioning and has been rated by 1 people with an average of a 9.5. This manual is available in the following languages: English. Do you have a question about the Electrolux EXI09HD1WI or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Electrolux and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Electrolux EXI09HD1WI specifications

Below you will find the product specifications and the manual specifications of the Electrolux EXI09HD1WI.

General
BrandElectrolux
ModelEXI09HD1WI
Productair-conditioning
LanguageEnglish
FiletypeUser manual (PDF)

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Electrolux EXI09HD1WI below.

What does BTU stand for?

BTU stands for British Thermal Unit and is a unit used to indicate cooling power.

What does R-410A stand for?

R-410A is a refrigerant used in machines that cool to zero degrees Celsius.

How often should I clean the filters of my Electrolux air conditioner?

The cleaner the filters, the better the air quality. This is why it is recommended to clean the filters of your Electrolux air conditioner at least four times a year.

Is the manual of the Electrolux EXI09HD1WI available in English?

Yes, the manual of the Electrolux EXI09HD1WI is available in English .

Is your question not listed? Ask your question here

No results