Dräger Alcotest 5510 manual

Dräger Alcotest 5510
7.2 · 1
PDF manual
 · 40 pages
English
manualDräger Alcotest 5510

Dräger Alcotest

®

5510

Atemalkohol-Messgerät

Breath Alcohol Monitor

i
de
Gebrauchsanweisung
3
en
Instructions for Use
20

View the manual for the Dräger Alcotest 5510 here, for free. This manual comes under the category alcohol testers and has been rated by 1 people with an average of a 7.2. This manual is available in the following languages: English. Do you have a question about the Dräger Alcotest 5510 or do you need help? Ask your question here

Need help?

Do you have a question about the Dräger and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 1
J
James CameronJuly 26, 2023

What is Error code 643 on Alcotest 5510

The Dräger Alcotest 5510 is a portable breathalyzer device used to measure a person's blood alcohol content (BAC). It is commonly used by law enforcement agencies to determine if an individual is driving under the influence of alcohol. The device is compact and lightweight, making it easy to carry and use in various situations. The Alcotest 5510 utilizes fuel cell sensor technology, which provides accurate and reliable results. This technology enables the device to measure alcohol concentration in the breath with high precision. It has a fast warm-up time, allowing for quick and efficient testing. The device features a clear and easy-to-read display, providing real-time BAC measurements. Users can navigate through the intuitive menu options to access various features and settings. The Alcotest 5510 also includes a data storage function, allowing for the retrieval of previous test results. To ensure the accuracy of the tests, the device is equipped with automatic calibration and self-diagnostic features. This helps maintain the reliability of the measurements over time. Additionally, the device has a long battery life, which allows for extended use without the need for frequent recharging. Overall, the Dräger Alcotest 5510 is a professional-grade alcohol tester that offers accuracy, efficiency, and reliability. It is a trusted tool used by law enforcement agencies to enforce alcohol-related laws and ensure road safety.

General
BrandDräger
ModelAlcotest 5510
Productalcohol tester
LanguageEnglish
FiletypeUser manual (PDF)

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Dräger Alcotest 5510 below.

How do I turn on the Dräger Alcotest 5510 alcohol tester?

To turn on the Dräger Alcotest 5510 alcohol tester, follow these steps: 1. Locate the Dräger Alcotest 5510 monitor, which is the main part of the device. 2. Ensure that the device has batteries installed. The Dräger Alcotest 5510 requires two batteries. 3. Press and hold the power button on the device. The power button is usually labeled as "ON" or indicated by a power symbol. 4. Wait for the device to power on. You may see a display screen light up or an indicator light turn on. 5. Once the device has powered on, it will go through a startup process. This may include a self-test or calibration procedure. 6. After the startup process is complete, the Dräger Alcotest 5510 alcohol tester is ready to use for breath alcohol measurement. Please note that the specific location and labeling of the power button may vary slightly depending on the model and version of the Dräger Alcotest 5510. Refer to the device's manual for detailed instructions if needed.

Why is the display of the Dräger Alcotest 5510 not showing any information?

The display of the Dräger Alcotest 5510 alcohol tester may not show any information due to the following reasons: 1. Insufficient Volume: If the sampling volume is too low, the display will show "Insufficient Volume." This indicates that the breath sample provided was not sufficient for measurement. To resolve this, ensure that you blow harder and more evenly during the breath sample. 2. Blow Interruption: If you exhale improperly, such as abruptly stopping or sucking at the end of the sampling, the display will show "Blow Interruption." This indicates an error in the breath sample. To resolve this, repeat the breath sample and ensure a continuous and steady exhale. 3. Accuracy Check Error: If the display shows "Accuracy Check Error," it means that the accuracy check was not successful. Repeat the accuracy check, and if the error persists, contact DrägerService for assistance. 4. Internal System Error: If the display shows "Internal System Error" with a service code, it indicates a unit fault. Remove the batteries for 2 seconds and reinsert them. If the error reappears, contact DrägerService for further support. Please note that these troubleshooting steps are specific to the Dräger Alcotest 5510 alcohol tester and may vary for other models or brands.

How do I insert a mouthpiece into the Dräger Alcotest 5510?

To insert a mouthpiece into the Dräger Alcotest 5510 alcohol tester, follow these steps: 1. Open the packaging of the mouthpiece. To maintain hygiene, keep the portion that will come in contact with your mouth covered by the packaging until the mouthpiece is correctly fitted to the instrument. 2. Hold the mouthpiece with the grooved markings facing up. 3. Press the mouthpiece into the mouthpiece receptacle of the device until you hear an audible sound, confirming that it is correctly engaged. 4. Remove the packaging completely from the mouthpiece. 5. You can now proceed with the breath test using the Dräger Alcotest 5510. Please note that the mouthpiece can be used with either left or right orientation. These steps ensure proper insertion of the mouthpiece for accurate breath alcohol measurement.

What should I do if the Dräger Alcotest 5510 is not measuring my breath alcohol correctly?

If the Dräger Alcotest 5510 is not measuring your breath alcohol correctly, follow these steps: 1. Ensure that you have followed the conditions and requirements for the test. Use a new mouthpiece for each test subject and avoid applying high alcohol concentrations to the sensor before the measurement. 2. Make sure that the person being tested has maintained a waiting period of at least 15 minutes after drinking alcohol. Residual alcohol in the mouth can affect the measurement. 3. Check that the person being tested is providing the required minimum air volume of 1.2 liters and maintaining a constant breath flow for a minimum blowing period. 4. If the device is displaying "Insufficient Volume," it means the sampling volume is too low. Repeat the breath sample and ensure a stronger and more even exhale. 5. If the device shows "Blow Interruption," it indicates an error in the breath sample. Repeat the breath sample and avoid abruptly stopping or sucking at the end of the sampling. 6. If the issue persists, press the "-" button to repeat the measurement. If necessary, wait for the instrument to recover before performing another measurement. Please note that these troubleshooting steps are specific to the Dräger Alcotest 5510 and may vary for other models or brands.

How do I properly store and transport the Dräger Alcotest 5510 in its case?

To properly store and transport the Dräger Alcotest 5510 in its case, follow these steps: 1. Ensure that the Dräger Alcotest 5510 is turned off before storing or transporting it. This helps conserve battery life and prevents accidental activation. 2. Place the Dräger Alcotest 5510 in its designated compartment within the case. The case is designed to securely hold the device and protect it from damage during transportation. 3. Make sure that all cables, such as the charging cable or data transfer cable, are neatly organized and stored in their respective compartments within the case. This helps prevent tangling and damage to the cables. 4. Close the case securely, ensuring that all latches or zippers are properly fastened. This helps protect the Dräger Alcotest 5510 from dust, moisture, and other external elements. 5. When transporting the case, handle it with care to avoid dropping or subjecting it to excessive force. This helps prevent any potential damage to the Dräger Alcotest 5510. By following these steps, you can safely store and transport the Dräger Alcotest 5510 in its case, ensuring its protection and longevity.

How do I insert the batteries into the Dräger Alcotest 5510?

To insert the batteries into the Dräger Alcotest 5510, follow these steps: 1. Gently press the lock on the battery cover and remove the cover. 2. Take note of the correct polarity and insert two 1.5V alkaline cells (Mignon, LR6, AA) or a rechargeable battery with a voltage of 2*1.2V NiMH. 3. Close the battery cover securely. It is important to ensure that the batteries are inserted correctly to avoid any damage to the instrument. Please note that charging the batteries while they are in the instrument or connecting a charger to the socket can cause damage, so it is advised not to do so. Remember to have replacement batteries available to ensure uninterrupted use of the Dräger Alcotest 5510.

Why is the display of the Dräger Alcotest 5510 not turning on?

If the display of the Dräger Alcotest 5510 is not turning on, you can try the following steps to troubleshoot the issue: 1. Check the batteries: Ensure that the batteries are not discharged. If they are, replace them with new ones. Refer to section 8.4 on page 31 of the manual for instructions on replacing the batteries. 2. Power up the instrument: If the instrument does not power up, it may be due to discharged batteries. Insert new batteries into the device. 3. Check the breath sample: If the display is not turning on, it could be because the test subject is not breathing continuously or vigorously enough. Ask the test subject to blow harder and more evenly. 4. Accuracy check error: If the display shows "Accuracy check error," repeat the accuracy check. If the error persists, contact DrägerService for assistance. 5. Measuring limits exceeded: If the measured breath alcohol concentration (BAC) exceeds the measuring limits, apply smaller concentrations for testing. 6. Internal system error: If the display shows "Internal System ERROR" with a service code, remove the batteries for 2 seconds and then reinsert them. If the error reappears, contact DrägerService for further support. Please note that these troubleshooting steps are specific to the Dräger Alcotest 5510 and may not apply to other models or products.

How do I navigate through the menu options on the Dräger Alcotest 5510?

To navigate through the menu options on the Dräger Alcotest 5510, follow these steps: 1. Turn on the instrument. When "WAIT" or "READY" appears on the display, the menu functions can be accessed. 2. For quick access to the menu, press the menu button shortly. 3. Use the up and down buttons to select the desired function. The selected function will be highlighted. 4. Activate the selected function by pressing the OK button. 5. The top line of the display will show the current menu function. 6. To return to the measurement mode or the previous menu level, select "return to measurement" or "return to menu" and press the OK button. 7. If no button is pressed within 120 seconds, the instrument will automatically return to the measuring mode. Please note that these steps are specific to the Dräger Alcotest 5510 and may not apply to other models or products.

What should I do if the Dräger Alcotest 5510 is not measuring breath alcohol accurately?

If the Dräger Alcotest 5510 is not measuring breath alcohol accurately, you can try the following steps to troubleshoot the issue: 1. Ensure proper breath sample: Make sure the test subject is blowing evenly into the mouthpiece without interruption. A continuous tone and the green lamp flashing indicate a sufficient breathing flow volume. 2. Check for sufficient air volume: Ensure that the test subject is providing the required minimum air volume of 1.2 liters. The breath flow must be constant for a minimum blowing period (usually 2 seconds). 3. Avoid interference: Keep a sufficient distance from transmitters and mobile phone antennas, as they can interfere with the measurement. Also, maintain a waiting period of at least 15 minutes after drinking alcohol to avoid residual alcohol in the mouth. 4. Use a new mouthpiece: Always use a new mouthpiece for each test subject to prevent contamination and ensure accurate measurements. 5. Avoid high alcohol concentrations: Do not rinse the mouth with high-grade alcohols shortly before the measurement, as it can reduce the sensor's service life. If the issue persists, it is recommended to contact DrägerService for further assistance. Please note that these steps are specific to the Dräger Alcotest 5510 and may not apply to other models or products.

How do I properly clean the mouthpiece receptacle of the Dräger Alcotest 5510?

To properly clean the mouthpiece receptacle of the Dräger Alcotest 5510, follow these steps: 1. Open the packaging of the mouthpiece. Keep the portion that comes in contact with the mouth covered by the packaging until the mouthpiece is correctly fitted to the instrument. 2. With the grooved markings facing up, press the mouthpiece into the mouthpiece receptacle until you hear an audible sound, confirming that it is correctly engaged. 3. Remove the packaging completely and proceed with the breath test. It is important to clean the mouthpiece receptacle regularly to maintain hygiene and ensure accurate measurements. You can use a soft cloth or tissue to wipe the mouthpiece receptacle after each use. Please note that these steps are specific to the Dräger Alcotest 5510 and may not apply to other models or products.

Is the manual of the Dräger Alcotest 5510 available in English?

Yes, the manual of the Dräger Alcotest 5510 is available in English .

Is your question not listed? Ask your question here

No results