Dell PowerEdge R540 manual

Dell PowerEdge R540
9.4 · 1
PDF manual
 · 179 pages
English
manualDell PowerEdge R540
64 GB LRDIMMs that are DDP (Dual Die Package) LRDIMMs must not be mixed with 128 GB LRDIMMs that are TSV (Through Silicon
Via/3DS) LRDIMMs.
x4 and x8 DRAM based memory modules can be mixed.
Up to two RDIMMs can be populated per channel regardless of rank count.
Up to two LRDIMMs can be populated per channel regardless of rank count.
A maximum of two different ranked DIMMs can be populated in a channel regardless of rank count.
If memory modules with different speeds are installed, they will operate at the speed of the slowest installed memory module(s).
Populate memory module sockets only if a processor is installed.
For single-processor systems, sockets A1 to A10 are available.
For dual-processor systems, sockets A1 to A10 and sockets B1 to B6 are available.
Populate all the sockets with white release tabs first, followed by the black release tabs.
When mixing memory modules with different capacities, populate the sockets with memory modules with the highest capacity first.
For example, if you want to mix 8 GB and 16 GB memory modules, populate 16 GB memory modules in the sockets with white release
tabs and 8 GB memory modules in the sockets with black release tabs.
Memory modules of different capacities can be mixed provided other memory population rules are followed.
For example, 8 GB and 16 GB memory modules can be mixed.
In a dual-processor configuration, the memory configuration for each processor must be identical.
For example, if you populate socket A1 for processor 1, then populate socket B1 for processor 2, and so on.
Mixing of more than two memory module capacities in a system is not supported.
Unbalanced memory configurations will result in a performance loss so always populate memory channels identically with identical
DIMMs for best performance.
Populate six identical memory modules per processor (one DIMM per channel) at a time to maximize performance.
To ensure proper system cooling, memory module blanks must be installed in memory sockets that are not occupied.
DIMM population update for Performance Optimized mode with quantity of 4 and 8 DIMMs per processor.
When the DIMM quantity is 4 per processor, the population is slot 1, 2, 4, 5.
When the DIMM quantity is 8 per processor, the population is slot 1, 2, 4, 5, 7, 8, 9, 10.
Identifier
GUID-7BC6FF1B-674F-4B65-BE86-1699131E66BA
Status Released

Mode-specific guidelines

The configurations allowed depend on the memory mode selected in the System BIOS.
Table 45. Memory operating modes
Memory Operating Mode Description
Optimizer Mode
The Optimizer Mode if enabled, the DRAM controllers operate
independently in the 64-bit mode and provide optimized memory
performance.
Mirror Mode The Mirror Mode if enabled, the system maintains two identical
copies of data in memory, and the total available system memory is
one half of the total installed physical memory. Half of the installed
memory is used to mirror the active memory modules. This feature
provides maximum reliability and enables the system to continue
running even during a catastrophic memory failure by switching
over to the mirrored copy. The installation guidelines to enable
Mirror Mode require that the memory modules be identical in size,
speed, and technology, and they must be populated in sets of 6 per
processor.
Single Rank Spare Mode Single Rank Spare Mode allocates one rank per channel as a
spare. If excessive correctable errors occur in a rank or channel,
while the operating system is running, they are moved to the spare
area to prevent errors from causing an uncorrectable failure.
Requires two or more ranks to be populated in each channel.
Multi Rank Spare Mode Multi Rank Spare Mode allocates two ranks per channel as a
spare. If excessive correctable errors occur in a rank or channel,
100 Installing and removing system components

Manual

View the manual for the Dell PowerEdge R540 here, for free. This manual comes under the category servers and has been rated by 1 people with an average of a 9.4. This manual is available in the following languages: English. Do you have a question about the Dell PowerEdge R540 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Dell and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Dell PowerEdge R540 specifications

Below you will find the product specifications and the manual specifications of the Dell PowerEdge R540.

The Dell PowerEdge R540 is a server that features an Intel Xeon processor. With 8 cores and 16 threads, it offers high performance and efficient multitasking capabilities. The processor model, 4110, has a base frequency of 2.1 GHz and a boost frequency of 3 GHz, allowing for smooth and fast operation. Equipped with an 11 MB processor cache, this server is able to store frequently accessed data for quick retrieval, optimizing overall performance. The R540 is designed to handle demanding workloads and can efficiently process complex tasks. With its powerful processor and ample cache, this server is well-suited for tasks such as data analysis, virtualization, and hosting multiple applications simultaneously. It provides the necessary resources to support demanding business operations. In addition to its impressive specifications, the Dell PowerEdge R540 boasts a reliable and durable build. It is constructed with high-quality materials, ensuring long-term performance and stability. This server is engineered to withstand the rigors of continuous operation, making it a suitable choice for businesses that require uninterrupted uptime. The Dell PowerEdge R540 is a dependable and capable server that combines a robust Intel Xeon processor with a high-performance cache. With its powerful performance capabilities and durable construction, this server is designed to meet the demands of modern businesses. Whether for data analysis, virtualization, or hosting applications, this server offers the resources and reliability necessary for efficient and smooth operation.

General
BrandDell
ModelPowerEdge R540 | 1KX77
Productserver
EAN5397184231746
LanguageEnglish
FiletypeUser manual (PDF), Installation Guide (PDF)
Processor
Processor familyIntel Xeon Silver
Processor cores8
Processor model4110
Processor boost frequency3 GHz
Processor threads16
Processor cache11 MB
Processor frequency2.1 GHz
Processor familyIntel® Xeon®
Processor cores8
Processor model4110
Processor boost frequency3 GHz
Processor threads16
Processor cache11 MB
Processor frequency2.1 GHz
Number of processors installed1
Processor lithography14 nm
Processor socketLGA 3647 (Socket P)
Supported instruction setsAVX, AVX 2.0, AVX-512, SSE4.2
System bus rate- GT/s
Processor operating modes64-bit
Execute Disable BitYes
Scalability2S
Tcase77 °C
Embedded options availableYes
Thermal Design Power (TDP)85 W
Processor codenameSkylake
Maximum number of PCI Express lanes48
Processor cache typeL3
Maximum internal memory supported by processor768 GB
Memory types supported by processorLPDDR4-SDRAM
Memory clock speeds supported by processor2400 MHz
Memory channels supported by processorHepta
ECC supported by processorYes
Processor package size76.0 x 56.5 mm
Conflict-Free processorYes
Processor manufacturerIntel
1st Generation Intel® Xeon® Scalable
Graphics
On-board graphics card model-
On-board graphics card-
Software
Compatible operating systems- Canonical Ubuntu LTS\n- Citrix XenServer\n- Microsoft Windows Server with Hyper-V\n- Red Hat Enterprise Linux\n- SUSE Linux Enterprise Server\n- VMware ESXi
Operating system installedNo
Memory
Internal memory typeDDR4-SDRAM
Memory slots16x DIMM
Internal memory16 GB
Maximum internal memory512 GB
Memory layout (slots x size)1 x 16 GB
2667 MT/s
Storage
Maximum storage capacity- TB
Optical drive typeNo
Total storage capacity240 GB
Number of HDDs installed0
HDD size- "
HDD interface-
RAID supportYes
Supported RAID controllersPERC H730P+ 2GB
Hot-Plug supportYes
Number of HDDs supported8
Supported HDD sizes3.5 "
SSD capacity240 GB
Number of SSDs installed1
Network
Ethernet interface typeGigabit Ethernet
Ethernet LANYes
Ports & interfaces
USB 2.0 ports quantity1
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity2
Ethernet LAN (RJ-45) ports2
Serial ports quantity1
VGA (D-Sub) ports quantity2
Design
Chassis typeRack (2U)
Product colorBlack
Redundant fans supportYes
Rack mountingYes
Rack railsYes
Operational conditions
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)10 - 80 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 3048 m
Non-operating altitude0 - 12000 m
Power
Redundant power supply (RPS) supportYes
Power supply750 W
Number of main power supplies1
Weight & dimensions
Width- mm
Height86.8 mm
Depth- mm
Package width918 mm
Package height284 mm
Package depth614 mm
Package weight34000 g
Packaging content
Cables includedAC
Performance
Remote administrationiDRAC9 Express
Processor special features
Intel® Hyper Threading Technology (Intel® HT Technology)Yes
Intel® Turbo Boost Technology2.0
Intel® AES New Instructions (Intel® AES-NI)Yes
Enhanced Intel SpeedStep TechnologyYes
Intel Trusted Execution TechnologyYes
Intel VT-x with Extended Page Tables (EPT)Yes
Intel TSX-NIYes
Intel 64Yes
Intel Virtualization Technology for Directed I/O (VT-d)Yes
Intel Virtualization Technology (VT-x)Yes
Processor ARK ID123547
Intel TSX-NI version1.00
Expansion slots
PCI Express slots version3.0
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Dell PowerEdge R540 below.

What does the download speed on the internet depend on?

The download speed on the internet depends on the type of connection you have. If you have a 25 Mb/s connection this means that theoretically you should be able to download 25 MB per second.

What is the height of the Dell PowerEdge R540?

The Dell PowerEdge R540 has a height of 86.8 mm.

What is the width of the Dell PowerEdge R540?

The Dell PowerEdge R540 has a width of - mm.

What is the depth of the Dell PowerEdge R540?

The Dell PowerEdge R540 has a depth of - mm.

Does Dell PowerEdge R540 have 16 memory slots?

Yes, Dell PowerEdge R540 has 16 memory slots, providing ample memory expansion options for the user.

Is Dell PowerEdge R540 equipped with Gigabit Ethernet interface?

Yes, Dell PowerEdge R540 features a Gigabit Ethernet interface, ensuring fast and reliable network connectivity for the user.

How many USB 3.2 Gen 1 Type-A ports does Dell PowerEdge R540 have?

Dell PowerEdge R540 has 2 USB 3.2 Gen 1 Type-A ports, allowing for high-speed data transfer and connectivity with peripherals.

What is the processor model of Dell PowerEdge R540?

Dell PowerEdge R540 comes with an Intel Xeon 4110 processor, providing high performance and efficiency for various computing tasks.

How many processor cores does Dell PowerEdge R540 have?

Dell PowerEdge R540 has 8 processor cores, offering strong multitasking capabilities and processing power compared to similar server products.

How do I troubleshoot issues with the front view of the Dell PowerEdge R540 server?

To troubleshoot issues with the front view of the Dell PowerEdge R540 server, follow these steps: 1. Ensure that the system is turned off, including any attached peripherals, and disconnect the system from the electrical outlet and peripherals. 2. Locate the latch release lock on the front of the system. It can be rotated counter clockwise using a 1/4 inch flat head or a Phillips #2 screwdriver to unlock it. 3. Lift the latch until the system cover slides back and the tabs on the system cover disengage from the guide slots on the system. 4. Hold the cover on both sides and lift it away from the system. 5. Inspect the front view of the server for any visible issues such as loose cables, damaged components, or obstructions. 6. If there are loose cables, ensure they are securely connected to their respective ports. 7. If there are damaged components, such as a malfunctioning LCD panel on the front bezel, consider replacing them. 8. If there are obstructions, remove them carefully without causing any damage to the server. 9. Once the troubleshooting steps are completed, reattach the system cover by aligning the tabs with the guide slots and sliding it forward until it locks into place. By following these steps, you can effectively troubleshoot issues with the front view of the Dell PowerEdge R540 server.

How can I troubleshoot issues with the LCD panel of the Dell PowerEdge R540 server?

To troubleshoot issues with the LCD panel of the Dell PowerEdge R540 server, follow these steps: 1. Check the color of the LCD backlight. During normal operating conditions, the backlight should be white. If it turns amber, it indicates that the system needs attention and displays an error code followed by descriptive text. Note that even if the system is turned off, the LCD will turn amber if an error is detected. 2. If the LCD panel stops responding, try removing the front bezel and reinstalling it. This can sometimes resolve the issue. If the problem persists, you may need to seek further assistance. 3. If the LCD messaging is turned off using the iDRAC utility, the LCD panel, or other tools, the backlight will remain off. Make sure that the messaging is enabled if you want to see system information, status, and error messages on the LCD panel. To view the Home screen on the LCD panel, press one of the three navigation buttons (Select, Left, or Right). This screen displays user-configurable information about the system during normal operation. When installing the front bezel, make sure to follow the safety guidelines and use the bezel key provided. Align and insert the right end of the bezel onto the system, then press it until the button clicks in place. Finally, fit the left end of the bezel onto the system and lock it using the key. Please note that these troubleshooting steps are specific to the Dell PowerEdge R540 server.

Where can I locate the Service Tag of my Dell PowerEdge R540 server if I need it for troubleshooting purposes?

To locate the Service Tag of your Dell PowerEdge R540 server for troubleshooting purposes, follow these steps: 1. Look for the information tag on the front or back of your server. The Service Tag is usually displayed on this tag. 2. If you have installed the OpenManage Mobile (OMM) application on your mobile device, you can find the Service Tag there as well. 3. Another option is to check the iDRAC (Integrated Dell Remote Access Controller) MAC address and iDRAC secure password label. The Service Tag may be listed there. Please note that the Service Tag is a unique identifier for your server and is important for support and warranty purposes. It is recommended to keep a record of your Service Tag in a safe place. By following these steps, you will be able to locate the Service Tag of your Dell PowerEdge R540 server easily and quickly for troubleshooting purposes.

Is the manual of the Dell PowerEdge R540 available in English?

Yes, the manual of the Dell PowerEdge R540 is available in English .

Is your question not listed? Ask your question here

No results