Introduction:

This blood pressure monitor conforms to the Euro-
pean requirements that are the basis of the Medi-
cal Products Law (CE), as well as to the European
Standard „Europanorm” EN 1060, Part 1 „Non-
Invasive blood pressure monitoring devices –
General requirements” and part 2 „Additiona
requirements for mechanical blood pressure moni-
toring devices“.
Regular calibration testing is to be carried out in ac-
cordance with the regulations existing in individual
countries.

Important:

Keep this unit from being knocked or dropped, and
protect it from dirt and moisture. Care has to be
taken not to puncture the cuff with any sharp
instruments (Scissors, Needles).
Do not inflate to above 300 mmHg !
Measurement time should be ca. 2 minutes
maximum.
Between 2 measurements allow an interval of at
least 2 minutes.

Placing the Cuff:

Place cuff in such a manner that the lower cuff
edge finishes ca. 2 – 3 cm above the elbow and
the centre of the rubber bag rests on top of the
artery.

Taking the Blood Pressure:

Inflate the cuff to above the systolic pressure. The
air release speed can be adjusted by rotating the
valve screw.
The World Health Organisation (WHO) recom-
mends a deflation speed of 2 – 3 mmHg per
second.
After the measurement is completed, fully open the
ai release valve to allow for the fast deflation of
the cuff.

Note on Cuff Sizes:

The German League for the Fight against Blood
Pressure recommends the following cuff sizes:

Technical Data:

Measurement range: 0 – 300 mmHg
Accuracy of Pressure indication: ± 3 mmHg

Instructions for Use

Patient Upper Arm
Circonfe-
rence in cm
Rubber Part of
Cuff in cm
Width x Legth (*)
Infant
Child
Adult
28 – 13
14 – 21
22 – 32
33 – 41
41 +
5 x 18
8 x 13
12 – 13 x 24
15 x 30
18 x 36
* The given lengths are minimum measurements.
Please use only
boso cuffs.

View the manual for the Boso Nova 2 here, for free. This manual comes under the category sphygmomanometer and has been rated by 1 people with an average of a 9.2. This manual is available in the following languages: English. Do you have a question about the Boso Nova 2 or do you need help? Ask your question here

Need help?

Do you have a question about the Boso and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

General
BrandBoso
ModelNova 2
Productsphygmomanometer
LanguageEnglish
FiletypeUser manual (PDF)

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Boso Nova 2 below.

What does systolic pressure mean?

Systolic pressure is the top number that the blood pressure monitor will indicate. Systolic pressure refers to the amount of pressure in your arteries during the contraction of your heart muscle.

What does diastolilc pressure mean?

Diastolic pressure is the lowest number that the blood pressure monitor will indicate. The bottom number refers to your blood pressure when your heart muscle is between beats.

What is a normal blood pressure?

A normal blood pressure is about 120/80.

Is the manual of the Boso Nova 2 available in English?

Yes, the manual of the Boso Nova 2 is available in English .

Is your question not listed? Ask your question here

No results