View the manual for the Boso Medicus System here, for free. This manual comes under the category sphygmomanometer and has been rated by 2 people with an average of a 9.4. This manual is available in the following languages: English. Do you have a question about the Boso Medicus System or do you need help? Ask your question here
| Brand | Boso |
| Model | Medicus System |
| Product | sphygmomanometer |
| Language | English |
| Filetype | User manual (PDF) |
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Boso Medicus System below.
Systolic pressure is the top number that the blood pressure monitor will indicate. Systolic pressure refers to the amount of pressure in your arteries during the contraction of your heart muscle.
Diastolic pressure is the lowest number that the blood pressure monitor will indicate. The bottom number refers to your blood pressure when your heart muscle is between beats.
A normal blood pressure is about 120/80.
To properly measure your blood pressure using the Boso Medicus System sphygmomanometer, follow these steps: 1. Prepare for the measurement: - Avoid smoking or drinking coffee for at least one hour before measuring. - Sit comfortably with your back and arms supported, and your feet flat on the floor. - Relax for 5 minutes before taking the measurement. 2. Attach the cuff: - Open the cuff into the shape of a ring and slide it over your upper arm, positioning the bottom edge of the cuff about 2-3 cm above your elbow. - Make sure the cuff is positioned over the artery on your upper arm. 3. Position your arm: - Place your arm with the cuff attached on a table, keeping it relaxed and slightly bent so that the cuff is level with your heart. 4. Take the measurement: - Do not talk during the measurement. - Check that the air tube is not kinked during the measurement to ensure accurate results. - The measurement should not prevent the flow of blood for an unnecessary length of time (more than 2 minutes). 5. After the measurement: - If the monitor fails to function correctly, remove the cuff from your arm. - Avoid excessive frequent measurements, as they can restrict blood flow and cause injury. Remember, the Boso Medicus System sphygmomanometer should not be used by unsupervised children and should not be used near infants to prevent accidents or damage.
The Boso Medicus System sphygmomanometer is not suitable for use on newborn babies and infants due to the following reasons: 1. Cuff Size: The cuff size of the Boso Medicus System sphygmomanometer is designed to fit the upper arms of adults. It may not provide an accurate and secure fit on the smaller arms of newborn babies and infants, leading to inaccurate blood pressure measurements. 2. Measurement Accuracy: The blood pressure measurement technology used in the Boso Medicus System sphygmomanometer is optimized for adult users. The physiological characteristics and blood pressure ranges of newborn babies and infants differ significantly from adults. Using the device on newborn babies and infants may result in inaccurate readings, which can be misleading and potentially harmful. 3. Safety Concerns: Newborn babies and infants have delicate and sensitive skin. The pressure applied by the cuff during measurement may cause discomfort, bruising, or injury to their arms. Additionally, the device may not have undergone specific safety testing for use on newborn babies and infants, posing potential risks. To ensure the safety and accuracy of blood pressure measurements, it is recommended to use a blood pressure monitor specifically designed for newborn babies and infants, following the guidance of a healthcare professional.
If the measurement results of the Boso Medicus System sphygmomanometer are outside the specified range for systolic and diastolic blood pressure, follow these steps: 1. Check the measurement technique: Ensure that you are following the correct measurement technique as described in the manual. Make sure the cuff is properly positioned on your upper arm and that you are in a relaxed state during the measurement. 2. Verify cuff placement: Double-check the placement of the cuff on your upper arm. Ensure that it is positioned correctly and securely, with the bottom edge of the cuff about 2-3 cm above your elbow. 3. Repeat the measurement: If the initial measurement results are outside the specified range, repeat the measurement. Take at least two consecutive measurements and compare the results. This helps to ensure accuracy and identify any inconsistencies. 4. Check cuff size: Confirm that you are using the correct cuff size for your arm circumference. Using an improperly sized cuff can lead to inaccurate readings. Refer to the manual for guidance on selecting the appropriate cuff size. 5. Consult a healthcare professional: If the measurement results consistently fall outside the specified range, it is recommended to consult a healthcare professional. They can provide further guidance, evaluate the accuracy of the device, and offer appropriate advice or treatment based on your individual circumstances. Remember, accurate blood pressure measurements are essential for monitoring your health. If you have any concerns or questions about the measurement results, it is always best to seek professional medical advice.
The recommended operating conditions for the Boso Medicus System sphygmomanometer are as follows: - Environmental Temperature: The device should be operated in an environmental temperature range of +10°C to +40°C. - Relative Humidity: The recommended relative humidity range for operation is 15% to 85%. - Air Pressure: The sphygmomanometer can be used within an air pressure range of 800 hPa to 1060 hPa. It is important to note that these operating conditions ensure optimal performance and accuracy of the device. Operating the sphygmomanometer outside of these specified conditions may affect its functionality and measurement accuracy. Please ensure that you use the Boso Medicus System sphygmomanometer within the recommended operating conditions to obtain reliable and accurate blood pressure measurements.
To ensure accurate measurements with the Boso Medicus System sphygmomanometer when using wireless communication devices nearby, follow these steps: 1. Check for wireless communication restrictions: Make sure you are not using the sphygmomanometer in locations where wireless communication is prohibited, such as aircraft or hospitals. 2. Maintain a suitable communication distance: The maximum communication distance between the blood pressure monitor and the receiver is approximately 10 meters. However, this distance can be affected by the environment. Verify that the distance is short enough for the transmission of data after the measurement. 3. Ensure unobstructed space: Make sure there are no obstructions between the blood pressure monitor and the mobile device. Obstacles like walls or other structures can shorten the communication distance. Reinforced concrete walls, in particular, may hinder communication under certain circumstances. 4. Activate Bluetooth on all devices: During pairing, ensure that Bluetooth is activated on all other devices within range to establish a connection. 5. Consider alternative locations: If the blood pressure monitor disrupts other wireless communication devices, consider using the monitor in a different location to avoid interference. By following these steps, you can help ensure accurate measurements with the Boso Medicus System sphygmomanometer even when using wireless communication devices nearby.
Yes, the manual of the Boso Medicus System is available in English .
Is your question not listed? Ask your question here
No results
Need help?
Do you have a question about the Boso and is the answer not in the manual?
Question and answer
Number of questions: 0