Cleaning and servicing en
7

8.4 Removing the grease filter

1.
ATTENTION!
Falling grease filters may damage the hob below.
Grip below the grease filter with one hand.
Open the locks on the grease filters.
2.
Remove the grease filters from the holders.
To prevent grease from dripping, hold the grease fil-
ter horizontally.

8.5 Cleaning grease filters manually

The grease filters filter the grease from the cooking va-
pour. Regularly cleaned grease filters guarantee a high
level of grease removal.
WARNING‒Risk of fire!
Fatty deposits in the grease filters may catch fire.
Clean the grease filters roughly once a month.
Requirement:The grease filters have been removed.
→"Removing the grease filter", Page7
1.
Observe the information regarding the cleaning
agents.
2.
Soak the grease filter in hot soapy water.
Use special grease solvent for stubborn dirt. You
can obtain grease solvents from after-sales service
or the online shop.
3.
Use a brush to clean the grease filters.
4.
Rinse the grease filters thoroughly.
5.
Allow the grease filters to drain.

8.6 Cleaning grease filters in the

dishwasher

The grease filters filter the grease from the cooking va-
pour. Regularly cleaned grease filters guarantee a high
level of grease removal.
WARNING‒Risk of fire!
Fatty deposits in the grease filters may catch fire.
Clean the grease filters roughly once a month.
ATTENTION!
The grease filters may become damaged if they are
squeezed.
Do not squeeze the grease filters.
Note:When cleaning the grease filter in the dish-
washer, light discolouration may occur. This discoloura-
tion has no effect on the performance of the metal
grease filters.
Requirement:The grease filters have been removed.
→"Removing the grease filter", Page7
1.
Observe the information regarding the cleaning
agents.
2.
Place the grease filters loosely into the dishwasher.
Do not clean heavily soiled grease filters with
utensils.
Use special grease solvent for stubborn dirt. You
can obtain grease solvents from after-sales service
or the online shop.
3.
Start the dishwasher.
Select a temperature of no more than 70°C.
4.
Allow the grease filters to drain.

8.7 Odour filter for recirculating air mode

Odour filters bind odorous substances in air recircula-
tion mode. Regularly replaced odour filters guarantee a
high level of odour removal.
With normal use (approx.onehour a day), the odour fil-
ter must be replaced every 3 months. The odour filter
cannot be cleaned or regenerated.
You can obtain odour filters from the after-sales service
or the online shop. Only use original odour filters.

Removing the odour filter

1.
Remove the grease filter. →Page7
2.
Remove the grid and the grease filter.

Fitting odour filters

1.
Place the odour filter on the grease filter.
2.
Use the grid to secure the odour filter.

8.8 Fitting grease filters

ATTENTION!
Falling grease filters may damage the hob below.
Grip below the grease filter with one hand.
1.
Fit the grease filters.
2.
Fold the grease filters upwards and engage the
locks.
3.
Make sure that the locks engage.

Manual

View the manual for the Bosch DLN53AA70 here, for free. This manual comes under the category exhaust hoods and has been rated by 1 people with an average of a 9.4. This manual is available in the following languages: English. Do you have a question about the Bosch DLN53AA70 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Bosch and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Bosch DLN53AA70 specifications

Below you will find the product specifications and the manual specifications of the Bosch DLN53AA70.

The Bosch DLN53AA70 exhaust hood has a energy efficiency class of D on a scale from A+++ to D. It is equipped with a 121 W motor and has an annual energy consumption of 68 kWh. The fluid dynamic efficiency class is E, while the lighting and grease filtering efficiency classes are D. This exhaust hood offers 3 different speeds and has a noise level of 62 dB. It has a width of 534 millimeters, a depth of 300 millimeters, and a maximum height of 208 millimeters. The noise level at low speed is 48 dB. There is no built-in display on this exhaust hood. The exhaust connection diameter is 120 millimeters. With these specifications, the Bosch DLN53AA70 exhaust hood offers reliable performance for kitchen ventilation needs.

General
BrandBosch
ModelDLN53AA70 | DLN53AA70
Productexhaust hood
EAN4242005095476
LanguageEnglish
FiletypeUser manual (PDF), Energy label (PDF)
Power
Energy efficiency classD
Energy efficiency scaleA+++ to D
Motor power121 W
Annual energy consumption68 kWh
AC input frequency50 Hz
AC input voltage220 - 240 V
Performance
Fluid dynamic efficiency classE
Lighting efficiency classD
Grease filtering efficiency classD
Number of speeds3
Noise level62 dB
Noise level (low speed)48 dB
Maximum extraction power302 m³/h
Type of extraction-
Weight & dimensions
Width534 mm
Depth300 mm
Height (max)208 mm
Design
Built-in displayNo
Exhaust connection diameter120 mm
Number of motors1
Cord length1.5 m
TypeBuilt-in
Product colorStainless steel
Control typeLever
Lighting
Bulb power3 W
Number of bulbs2 bulb(s)
Bulb typeLED
Illuminance78 lx
Lighting positionBack
Filtering
Grease filter typeAluminum
Filter cleaning indicator-
Dishwasher proof filter-
Removable filterYes
Washable filterYes
Number of filters1 pc(s)
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Bosch DLN53AA70 below.

When should I replace the carbon filter on my extractor hood?

The carbon filter should be replaced every three to twelve months.

How often should I clean the metal hood grease filters?

The metal grease filters should be cleaned every eight to ten weeks.

Where can I find the model number of my cooker ectractor hood?

The model number of the hood is usually found on a white label inside the hood.

What is the width of the Bosch DLN53AA70?

The Bosch DLN53AA70 has a width of 534 mm.

What is the depth of the Bosch DLN53AA70?

The Bosch DLN53AA70 has a depth of 300 mm.

What energy label does the Bosch DLN53AA70 have?

The Bosch DLN53AA70 has energy label D.

What is the energy efficiency rating of the Bosch DLN53AA70?

The energy efficiency scale of the Bosch DLN53AA70 ranges from A+++ to D, indicating its energy efficiency performance. Compared to comparable products, it may have lower energy consumption.

How powerful is the motor of the Bosch DLN53AA70?

The motor power of the Bosch DLN53AA70 is 121 W, providing sufficient power for effective extraction of cooking fumes.

How much energy does the Bosch DLN53AA70 consume annually?

The Bosch DLN53AA70 has an annual energy consumption of 68 kWh. This indicates its energy efficiency performance, with lower energy consumption being more favorable for users.

What is the fluid dynamic efficiency class of the Bosch DLN53AA70?

The Bosch DLN53AA70 is classified as fluid dynamic efficiency class E. This classification suggests that its fluid dynamics may be less efficient compared to higher-rated products in terms of airflow and extraction efficiency.

What is the noise level of the Bosch DLN53AA70 at its lowest speed?

The noise level of the Bosch DLN53AA70 at its lowest speed is 48 dB. This indicates a relatively quiet operation, which can be beneficial for a more peaceful cooking environment.

How do I switch between different modes of operation on the Bosch DLN53AA70 exhaust hood?

To switch between different modes of operation on the Bosch DLN53AA70 exhaust hood, follow these steps: 1. Modes of Operation: The exhaust hood offers different modes of operation, including air extraction and recirculation. 2. Air Extraction: If you want to use the air extraction mode, make sure that the exhaust air is not directed into a ventilation opening used for gas or fuel appliances. If the exhaust air is directed through a vent that is not in use, it must be approved by a qualified chimney sweep. If the exhaust air is directed through an external wall, a telescopic channel should be used. 3. Recirculation Operation: If you prefer the recirculation mode, you need to install a carbon filter to eliminate unpleasant odors. Information about the different recirculation modes and the required accessories can be found in the product brochure or obtained from the seller. 4. Control Panel: The control panel allows you to operate the exhaust hood. Use the buttons or sliders on the control panel to adjust the settings. For example, you can turn on/off the fan, adjust the fan speed, and control the lighting. By following these steps, you can easily switch between different modes of operation on the Bosch DLN53AA70 exhaust hood.

Why is the air extraction not working properly on my Bosch DLN53AA70 exhaust hood?

There could be several reasons why the air extraction is not working properly on your Bosch DLN53AA70 exhaust hood. Here are some possible causes and troubleshooting steps: 1. Check the Ventilation Opening: Ensure that the exhaust air is not directed into a ventilation opening used for gas or fuel appliances. If it is, the exhaust air must be approved by a qualified chimney sweep. 2. Verify the Telescopic Channel: If the exhaust air is directed through an external wall, make sure that a telescopic channel is properly installed. This helps to ensure the correct airflow. 3. Clean the Filters: Over time, the grease filters may become clogged with grease and dirt, which can affect the air extraction. Clean the filters regularly according to the manufacturer's instructions. 4. Check for Blockages: Inspect the exhaust duct and vent for any blockages that may be obstructing the airflow. Remove any debris or obstructions that you find. 5. Contact Customer Support: If the above steps do not resolve the issue, it is recommended to contact Bosch customer support for further assistance. They can provide specific troubleshooting advice or arrange for a service technician to inspect the exhaust hood. By following these steps, you can troubleshoot and address the issue of the air extraction not working properly on your Bosch DLN53AA70 exhaust hood.

How do I set up the recirculation operation on the Bosch DLN53AA70 exhaust hood?

To set up the recirculation operation on the Bosch DLN53AA70 exhaust hood, follow these steps: 1. Install the Carbon Filter: To eliminate unpleasant odors during recirculation operation, you need to install a carbon filter. Refer to the product brochure or consult the seller for information on the specific carbon filter required for your exhaust hood. 2. Access the Control Panel: Locate the control panel on the exhaust hood. It is usually located on the front or underside of the hood. 3. Select Recirculation Mode: Use the buttons or sliders on the control panel to navigate the settings. Look for the option to switch to recirculation mode. This mode allows the air to be filtered and recirculated back into the kitchen. 4. Adjust Fan Speed: Depending on your preference, you can adjust the fan speed to control the airflow during recirculation. Use the control panel to increase or decrease the fan speed as desired. 5. Activate the Recirculation Operation: Once you have selected the recirculation mode and adjusted the fan speed, activate the recirculation operation by pressing the corresponding button on the control panel. By following these steps, you can successfully set up the recirculation operation on your Bosch DLN53AA70 exhaust hood.

What are the different components and features of the Bosch DLN53AA70 exhaust hood?

The Bosch DLN53AA70 exhaust hood is equipped with various components and features. Here are the different components and features of the Bosch DLN53AA70 exhaust hood: 1. Modes of Operation: The exhaust hood offers different modes of operation, including air extraction and recirculation. 2. Carbon Filter: The recirculation mode requires the installation of a carbon filter to eliminate unpleasant odors. 3. Grease Filters: The exhaust hood is equipped with grease filters that clean the air by capturing grease and dirt particles. 4. Control Panel: The control panel allows you to operate the exhaust hood. It includes buttons or sliders to adjust the fan speed, control the lighting, and activate different modes of operation. 5. Lighting: The exhaust hood features built-in lighting to provide illumination over the cooking area. 6. Telescopic Channel: If the exhaust air is directed through an external wall, a telescopic channel should be used to ensure proper airflow. 7. Safety Features: The exhaust hood is designed with safety features to prevent accidents, such as sharp edges and warnings about hot surfaces. These are the main components and features of the Bosch DLN53AA70 exhaust hood.

Why is the control panel not responding to my commands on the Bosch DLN53AA70 exhaust hood?

There could be several reasons why the control panel is not responding to your commands on the Bosch DLN53AA70 exhaust hood. Here are some possible causes and troubleshooting steps: 1. Power Supply: Ensure that the exhaust hood is properly connected to a power source. Check if the power cord is securely plugged into an outlet. 2. Control Panel Lock: Some models have a control panel lock feature to prevent accidental changes. Check if the control panel is locked and unlock it if necessary. Refer to the user manual for instructions on how to unlock the control panel. 3. Control Panel Settings: Verify that the control panel settings are correctly configured. Make sure that the desired mode of operation, fan speed, and lighting settings are selected. 4. Reset the Hood: Try resetting the exhaust hood by turning off the power supply for a few minutes and then turning it back on. This can help to resolve temporary issues with the control panel. 5. Contact Customer Support: If the above steps do not resolve the issue, it is recommended to contact Bosch customer support for further assistance. They can provide specific troubleshooting advice or arrange for a service technician to inspect the exhaust hood. By following these steps, you can troubleshoot and address the issue of the control panel not responding to your commands on the Bosch DLN53AA70 exhaust hood.

Is the manual of the Bosch DLN53AA70 available in English?

Yes, the manual of the Bosch DLN53AA70 is available in English .