9 708 069 951 Page1

Installation / Operating Instructions

GOOD.BEETER>BOSCH

BOSCH 13P & 16P

Continuous Flow Gas Water Heater

1 Main Cover 5 Cold Water Inlet
2 Inspection Window 6 Hot Water Supply
3 Access Panel 7 Mounting Point
4 Gas Inlet 8 Horizontal Flue
A-D Dimensions on page 2 Fig 3
Fig. 1
This appliance must be installed in accordance with the manufacturer’s installation instructions,
AG 601, NZ 5261, AS/NZS 3500.4.2
and all Local Water, Building and Gas fitting regulations

To be installed and serviced only by an authorised person

This appliance is not suitable for use as a pool heater

The “authorised installing person” is responsible for :
1. Correct commissioning of this appliance.
2. Ensure unit performs to the specifications stated on the rating label.
3.. Demonstrate operation of unit to customer before leaving.
4. Hand these instructions to customer.
Failure to install this appliance in accordance with these installation instructions may
void warranty
In the interest of continued product improvement, Bosch reserves ther right to alter the specifications
without notice.
25/10/2011

View the manual for the Bosch 16P here, for free. This manual comes under the category water heaters & boilers and has been rated by 1 people with an average of a 7.5. This manual is available in the following languages: English. Do you have a question about the Bosch 16P or do you need help? Ask your question here

Need help?

Do you have a question about the Bosch and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

The Bosch 16P water heater and boiler is a household appliance that provides reliable and efficient hot water heating. This model is known for its durability and long-lasting performance. The Bosch 16P is designed with high-quality materials and built to withstand the test of time. It offers a compact and space-saving design, making it suitable for various residential settings. This water heater and boiler delivers hot water quickly and efficiently, ensuring a continuous supply of hot water for daily use. It operates with a high energy efficiency rating, reducing energy consumption and saving on utility bills. The Bosch 16P is equipped with advanced safety features to provide peace of mind. It includes a temperature control system to prevent overheating and a pressure relief valve to prevent excessive pressure buildup. Installation and maintenance of the Bosch 16P are straightforward, thanks to its user-friendly design. It is compatible with various plumbing systems and can be easily integrated into existing setups. Although specific specifications may vary, the Bosch 16P water heater and boiler typically offers a generous capacity, allowing for sufficient hot water supply for the average household. It is designed to deliver reliable performance and durability, ensuring long-term satisfaction for homeowners. Overall, the Bosch 16P water heater and boiler is a reliable and efficient option for those in need of hot water heating for their household. With its durable construction, energy efficiency, and user-friendly design, it is a practical choice for homeowners.

General
BrandBosch
Model16P
Productwater heater & boiler
LanguageEnglish
FiletypeUser manual (PDF)

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Bosch 16P below.

What is the ideal room temperature?

Most people find that the ideal room temperature is between 19 and 22 degrees Celsius.

What should I do in areas where the atmospheric temperature may drop below 0°C to prevent damage to the Bosch 16P water heater & boiler?

In areas where the atmospheric temperature may drop below 0°C, it is important to prevent damage to the Bosch 16P water heater & boiler by draining the heater to avoid expansion of freezing water. Additionally, for locations where the temperature briefly falls below zero degrees Celsius, installing an EXOGEL expansion valve, part number H707060151, can help minimize the risk of damage to the appliance. However, it is crucial to note that the water heater MUST NOT be installed in areas where the temperature consistently remains below 0°C for extended periods to prevent any potential damage. Regular inspection and cleaning of the appliance by an authorized person, at least once a year, is also recommended to ensure its proper functioning.

How can I minimize the possibility of damage to the appliance during freezing weather conditions for the Bosch 16P water heater & boiler?

To minimize the possibility of damage to the Bosch 16P water heater & boiler during freezing weather conditions, follow these steps: 1. Drain the heater in areas where the temperature may drop below 0°C to prevent damage from freezing water expansion. 2. Consider installing an EXOGEL expansion valve (part number H707060151) to minimize the risk of damage in locations with temperatures below zero °C for brief periods. 3. Avoid installing the water heater in areas where the temperature remains below 0°C for extended periods to prevent potential damage. 4. Regularly inspect and clean the appliance by an authorized person, with a frequency of at least once a year, depending on usage duration. These steps will help protect your Bosch 16P water heater & boiler from damage during freezing weather conditions.

What is the recommended part number for the EXOGEL expansion valve to minimize the possibility of damage to the Bosch 16P water heater & boiler during freezing weather?

To minimize the possibility of damage to the Bosch 16P water heater & boiler during freezing weather, it is recommended to install the EXOGEL expansion valve with part number H707060151. This valve helps prevent damage caused by the expansion of freezing water in areas where the temperature may drop below 0°C. It is crucial to drain the heater in such conditions to avoid any harm. The installation of the EXOGEL expansion valve is particularly beneficial for appliances located in areas where the temperature falls below zero °C for brief periods. Remember, the water heater should not be installed in locations where the temperature remains below 0°C for extended periods to ensure its proper functioning and longevity.

Is the manual of the Bosch 16P available in English?

Yes, the manual of the Bosch 16P is available in English .

Is your question not listed? Ask your question here

No results