View the manual for the Beurer IH 30 here, for free. This manual comes under the category inhalators and has been rated by 2 people with an average of a 7.4. This manual is available in the following languages: English. Do you have a question about the Beurer IH 30 or do you need help? Ask your question here
Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Beurer IH 30 below.
To check for damage or defects in the Beurer IH 30 inhalator, follow these steps: 1. After opening the packaging, carefully inspect the inhalator and its accessories for any signs of damage or defects. Pay attention to the body of the inhalator, the accessories, and the power line adapter. 2. If you notice any damage or defects, such as cracks, dents, or malfunctioning parts, do not use the inhalator. Instead, contact your dealer immediately for assistance and further instructions. 3. Ensure that you use the inhalator only for its intended purpose, which is aerosol therapy. Using it for any other purpose may be dangerous and can result in damage or injury. The manufacturer cannot be held responsible for any damage caused by improper or incorrect usage. 4. When using the inhalator, always supervise frail persons and children. Never leave the inhalator and its accessories in the unsupervised hands of children. 5. Before using the inhalator, make sure that the supply voltage stated on the power line adapter matches the local supply voltage. Using the wrong voltage can damage the inhalator. 6. Use only the power line adapter supplied with the inhalator. Using a different adapter may cause the inhalator to become defective. 7. Fill the water tank of the inhalator with pure water only. Using other liquids can damage the inhalator. 8. During use, avoid tilting or shaking the inhalator. This can cause the medicament to mix with the water in the tank, affecting its effectiveness. 9. Keep the inhalator away from your eyes during use to prevent any potential injury from the medicament mist. 10. Always follow the doctor's instructions regarding the type of medicament to be used, the dosage, and the duration of inhalation. 11. Do not operate the inhalator in the presence of flammable gases. 12. Never touch the power cord or power line adapter with wet hands to avoid the risk of electric shock. 13. Clean the inhalator according to the provided instructions to maintain its performance and hygiene. 14. Only one person should use the inhalator to avoid cross-infection. 15. If you find that the inhalator is not functioning correctly or is damaged, switch it off, disconnect it from the power source, and contact your authorized dealer for assistance. Only use Beurer spare parts for repairs or replacements. Please note that these steps are specific to the Beurer IH 30 inhalator and may not apply to other models or brands.
If the Beurer IH 30 inhalator is not producing aerosol during therapy, you can follow these steps to troubleshoot the issue: 1. Check the power supply: Ensure that the power line adapter or battery is properly connected to the inhalator. Make sure the battery is fully charged if you are using it. 2. Verify the water level: Ensure that the water tank is properly filled. The minimum recommended level is 2ml, and the maximum is 5ml. If the water level is too low, the inhalator may not produce aerosol. 3. Inspect the medicament cup: Check that the medicament cup is not broken and is sufficiently filled with the prescribed medication. The cup should contain a minimum of 2ml and a maximum of 5ml of medication. 4. Clean the inhalator: If the above steps do not resolve the issue, clean the inhalator as described in the manual. Remove the top cover, medicament cup, air filter, and filter case. Clean these parts with a damp cloth and mild detergent or disinfectant. Rinse the water tank thoroughly with clear water. 5. Check the fan: Ensure that the fan is securely and correctly connected to the motor shaft. If the fan is not operating correctly, it may affect the aerosol production. If the problem persists after following these steps, it is recommended to send the inhalator for repair to the appropriate service center.
To properly clean the water tank of the Beurer IH 30 inhalator, follow these steps: 1. Ensure that the inhalator is switched off and disconnected from the power source. 2. Remove the top cover of the inhalator. 3. Empty the water tank completely. 4. Clean the water tank, top cover, and any removable parts (such as the medicament cup, air filter, and filter case) with a damp cloth and mild detergent or disinfectant. Follow the manufacturer's instructions for cleaning and disinfection. 5. Rinse the water tank thoroughly with clear water to remove any residue. 6. Use a soft, dry cloth to clean the small fan and the air inflow under the rear cover. Do not immerse the inhalator in water, as it could be damaged. 7. Allow all the parts to air dry completely before reassembling the inhalator. 8. Once dry, reassemble the inhalator by placing the top cover back on and ensuring it snaps into place. 9. The water tank is now ready to be filled with tap water or distilled water (at a temperature of 20-30°C) for the next use. Remember to clean the water tank after every session and fill it again each time the inhalator is used to maintain proper hygiene and functionality.
Yes, the manual of the Beurer IH 30 is available in English .