AstralPool Viron Inverter iHP120 manual

AstralPool Viron Inverter iHP120
9.1 · 1
PDF manual
 · 40 pages
English
manualAstralPool Viron Inverter iHP120
The appliance is not intended for use by young children
3/08/2017

VIRON RANGE

INVERTER HEAT PUMPS

Installation & Instruction manual
INSTALLATION AND OPERATING INSTRUCTIONS
I
INSTALLATION AND OPERATING INSTRUCTIONS

Viron Range

Inverter Heat Pumps

Manual

View the manual for the AstralPool Viron Inverter iHP120 here, for free. This manual comes under the category heaters and has been rated by 1 people with an average of a 9.1. This manual is available in the following languages: English. Do you have a question about the AstralPool Viron Inverter iHP120 or do you need help? Ask your question here

Need help?

Do you have a question about the AstralPool and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 1
S
Stewart RobertsonMarch 14, 2024

Process to adjust pool temperature

AstralPool Viron Inverter iHP120 specifications

Below you will find the product specifications and the manual specifications of the AstralPool Viron Inverter iHP120.

General
BrandAstralPool
ModelViron Inverter iHP120
Productheater
LanguageEnglish
FiletypeUser manual (PDF)

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the AstralPool Viron Inverter iHP120 below.

What is the ideal room temperature?

Most people find that the ideal room temperature is between 19 and 22 degrees Celsius.

How should I wire the AstralPool Viron Inverter iHP120 heater for electrical connection?

To wire the AstralPool Viron Inverter iHP120 heater for electrical connection, follow these steps: 1. Remove the screws and front panel of the unit to access the molded-in junction box with a conduit nipple. 2. Feed your supply lines through the conduit nipple and wire-nut the electric supply wires to the connections in the junction box. 3. Connect the heater to a dedicated AC power supply branch circuit with the proper circuit protection. 4. Install a disconnect means within sight and accessible from the unit for safety during servicing. 5. Start the unit by turning on the filter pump and then the electrical power supply. 6. Monitor the unit's operation and ensure proper cooling before adjusting settings. 7. Allow the unit and pool pump to run continuously until the desired pool water temperature is reached. 8. The unit will automatically restart when the pool temperature drops below the set temperature.

What should I do if the unit does not start automatically after turning on the electrical power supply?

To troubleshoot if the AstralPool Viron Inverter iHP120 heater does not start automatically after turning on the electrical power supply, follow these steps: 1. Ensure the filter pump is running to circulate water through the heat exchanger. 2. Check for water leaks and verify water flow to and from the pool. 3. Turn on the electrical power supply to the unit and press the key ON/OFF on the wire controller. It should start within several seconds. 4. Confirm that the air leaving the top or side of the unit is cooler (between 5-10 degrees Celsius). 5. Turn off the filter pump while the unit is operating to check if it turns off automatically. 6. Allow the unit and pool pump to run 24 hours a day until the desired pool water temperature is reached. 7. The unit will automatically restart when the pool temperature drops more than 0.2 degrees below the set temperature.

Is the manual of the AstralPool Viron Inverter iHP120 available in English?

Yes, the manual of the AstralPool Viron Inverter iHP120 is available in English .

Is your question not listed? Ask your question here