Chapter 4: Safety Precautions and Site Requirements
86 Section II: Installing the Chassis

Selecting a Site for the SwitchBlade x8112

Please perform the following procedure to determine the suitability of the
site for the chassis:
1. Verify that the equipment rack is safely secured so that it will not tip
over. You should install devices starting at the bottom of the rack, with
the heavier devices near the bottom.
2. Verify that the power outlets for the chassis are located near the unit
and are easily accessible.
3. Verify that the power sources are on different A/C circuits to protect
the unit from a power circuit failure.
4. Verify that the site has dedicated power circuits or power conditioners
to supply reliable electrical power to the network devices.
5. Verify that the site allows for easy access to the ports on the front of
the chassis so that you can easily connect and disconnect the network
cables, as well as view the unit’s LEDs.
6. Verify that the site allows for adequate air flow around the unit and
through the cooling vents. The ventilation direction for the main section
of the chassis is from left to right (when facing the front of the chassis),
with the fan module drawing air out of the chassis. The power supplies
have fans that draw air from the front to the back.
7. Verify that the site has a reliable and earth (grounded) power supply
source, preferably dedicated and filtered.
8. Verify that the twisted pair cabling is not exposed to sources of
electrical noise, such as radio transmitters, broadband amplifiers,
power lines, electric motors, and fluorescent fixtures.
9. Verify that the site protects the chassis from moisture, water, and dust.
Here are other guidelines to consider:
Switch ports are suitable for intra-building connections, or where
non-exposed cabling is required.
Do not place objects on top of the chassis.
The power cords provided with the AT-SBxPWRSYS1 and AT-
SBxPWRPOE1 Power Supplies for 100-125 VAC installations
have 20 Amp, 125 V NEMA 5-20P plugs. The plugs are only
compatible with NEMA 5-20R receptacles. See Figure 27 on page
87.

Manual

View the manual for the Allied Telesis AT-SBX81XS6 here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.6. This manual is available in the following languages: English. Do you have a question about the Allied Telesis AT-SBX81XS6 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Allied Telesis and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Allied Telesis AT-SBX81XS6 specifications

Below you will find the product specifications and the manual specifications of the Allied Telesis AT-SBX81XS6.

General
BrandAllied Telesis
ModelAT-SBX81XS6 | AT-SBX81XS6
Productnot categorized
EAN0767035195957, 767035195957, 7670351959574
LanguageEnglish
FiletypeUser manual (PDF)
Optical fiber
Fiber optic connectorSFP+
Data transmission
Data transfer rate10 Gbit/s
Ports & interfaces
Fiber ports quantity6
Performance
Compatibilityx8100
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Allied Telesis AT-SBX81XS6 below.

Is the manual of the Allied Telesis AT-SBX81XS6 available in English?

Yes, the manual of the Allied Telesis AT-SBX81XS6 is available in English .

Is your question not listed? Ask your question here

No results