Allied Telesis AT-SBX81XS6 manual

Allied Telesis AT-SBX81XS6
8.6 · 1
PDF manual
 · 314 pages
English
manualAllied Telesis AT-SBX81XS6
Chapter 15: Building a Stack
296 Section III: Building a Stack with VCStack Plus
so that its active master controller card becomes the active card for the
stack and its configuration file is used as the initial configuration for the
stack.
After the stack is operating, the active master card periodically shares its
configuration file with all the other controller cards in the stack. Thus, the
order in which the units are subsequently reset or powered on is not
important because all the controller cards have the same configuration file.

Powering On the

Switches

To power on the two chassis of the stack, do one of the following:
To power on the AT-SBxPWRSYS1 AC and AT-SBxPWRPOE1
PoE Power Supplies, connect the power cords to the appropriate
connectors on the back panel and to power sources. For
instructions, refer to “Powering On the AT-SBxPWRSYS1 AC
System Power Supply” on page 165 and “Powering On the AT-
SBxPWRPOE1 Power Supply” on page 168, respectively.
To power on the AT-SBxPWRSYS1 DC Power Supply, turn the
power switch to on. Refer to Figure 57 on page 122.
Be sure to power on all the power supplies in the chassis.
Note
To power on the two chassis in sequence to control the selection of
the active master controller card, power on one unit and then wait a
minimum of ten seconds before powering on the second unit.
The boot up sequence for the stack takes approximately four minutes. The
amount of time may vary, depending on the number and types of Ethernet
line cards in the two switches. The ports do not begin to forward traffic until
the stack has completed the initialization process.
Do one of the following:
If you want to monitor the switches as they perform the initialization
process, go to “Monitoring the Boot Up Sequence” on page 296.
If you do not want to monitor the initialization process, go to
“Verifying the Stack” on page 299.

Monitoring the

Boot Up

Sequence

You may monitor the initialization process by connecting a terminal or PC
with a terminal emulator program to the Console port on any of the
controller cards and watch the status messages, shown in Figure 181 on
page 297 and Figure 182 on page 298. (The settings for the terminal or
terminal emulator program are found in “Using Local Management to
Verify the Chassis” on page 204.)
After the stack has completed the initialization process, go to “Verifying
the Stack” on page 299.

Manual

View the manual for the Allied Telesis AT-SBX81XS6 here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.6. This manual is available in the following languages: English. Do you have a question about the Allied Telesis AT-SBX81XS6 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Allied Telesis and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Allied Telesis AT-SBX81XS6 specifications

Below you will find the product specifications and the manual specifications of the Allied Telesis AT-SBX81XS6.

General
BrandAllied Telesis
ModelAT-SBX81XS6 | AT-SBX81XS6
Productnot categorized
EAN0767035195957, 767035195957, 7670351959574
LanguageEnglish
FiletypeUser manual (PDF)
Optical fiber
Fiber optic connectorSFP+
Data transmission
Data transfer rate10 Gbit/s
Ports & interfaces
Fiber ports quantity6
Performance
Compatibilityx8100
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Allied Telesis AT-SBX81XS6 below.

Is the manual of the Allied Telesis AT-SBX81XS6 available in English?

Yes, the manual of the Allied Telesis AT-SBX81XS6 is available in English .

Is your question not listed? Ask your question here

No results