Chapter 10: Verifying the Hardware Operations of the Chassis
202 Section II: Installing the Chassis

Using the LEDs to Verify the Chassis

After powering on the chassis for the first time and waiting a minimum of
three minutes for the line and controller cards to complete the initialization
process, check the operational status of the various hardware
components by examining the LEDs, as explained in this procedure:
1. Check the LEDs on the power supplies:
AT-SBxPWRSYS1 and AT-SBxPWRPOE1 AC Power Supplies:
The power supplies are operating properly when the AC and DC
LEDs are solid green and Fault LEDs are off. If there is a problem
with a power supply, refer to “AT-SBxPWRSYS1 and AT-
SBxPWRPOE1 AC Power Supplies” on page 208 for
troubleshooting suggestions.
AT-SBxPWRSYS1 DC Power Supply: The power supply is
operating properly when the DC IN and DC OUT LEDs are solid
green and the Fault LED is off. If there is a problem, refer to “AT-
SBxPWRSYS1 DC System Power Supply” on page 209 for
troubleshooting suggestions.
2. Check the Power LED on the AT-SBxFAN12 module. The module is
operating normally when the LED is solid green. If the LED is off, the
fan module has a problem or failed. Power off the chassis and contact
your Allied Telesis representative for assistance. Do not operate the
chassis without a fully operational fan unit.
3. If the chassis has one controller card, check the CFC LED on the card.
It should be solid green. If the LED is flashing green, the card is still
initializing its AlliedWare Plus Operating System. Wait another minute
and check the LED again. If the LED is still flashing green, the card
may have encountered a problem that prevents it from completing the
initialization process. Power off the chassis and replace the controller
card.
Note
If all the LEDs on the controller card are off, they may have been
turned off. Try pressing the eco-friendly button on the card to turn
them on.
4. If the chassis has two controller cards, check the CFC LEDs on both
cards. The cards are operating correctly when the LEDs are solid
green on one card and solid amber on the other. If both LEDs are
flashing green, the controller cards are still completing the initialization
process. If the LEDs do not change to solid green and amber after
another minute, the cards may have encountered a problem that

Manual

View the manual for the Allied Telesis AT-SBX81XS6 here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.6. This manual is available in the following languages: English. Do you have a question about the Allied Telesis AT-SBX81XS6 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Allied Telesis and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Allied Telesis AT-SBX81XS6 specifications

Below you will find the product specifications and the manual specifications of the Allied Telesis AT-SBX81XS6.

General
BrandAllied Telesis
ModelAT-SBX81XS6 | AT-SBX81XS6
Productnot categorized
EAN0767035195957, 767035195957, 7670351959574
LanguageEnglish
FiletypeUser manual (PDF)
Optical fiber
Fiber optic connectorSFP+
Data transmission
Data transfer rate10 Gbit/s
Ports & interfaces
Fiber ports quantity6
Performance
Compatibilityx8100
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Allied Telesis AT-SBX81XS6 below.

Is the manual of the Allied Telesis AT-SBX81XS6 available in English?

Yes, the manual of the Allied Telesis AT-SBX81XS6 is available in English .

Is your question not listed? Ask your question here

No results