Chapter 9: Powering On the Chassis
178 Section II: Installing the Chassis

Choosing a

Method for

Attaching the

Power Wires

The AT-SBxPWRSYS1 DC Power Supply comes with the two sets of
power wire terminals shown in Figure 115. You may use either set to
connect the positive (+) and negative (-) wires to the terminal block on the
power supply. The straight terminals are used to route the wires above or
below the terminal block. The right angle terminals are used to route the
power wires directly away from the terminal block.
Figure 115. Power Wire Terminals
Note
The right angle terminals require the removal of the plastic cover
from the terminal block.
You may also install the wires using bare wires.
Here are the procedures to wiring the positive and negative terminal block
on the power supply:
“Connecting the DC Power Wires with the Straight Terminals”
“Connecting the DC Power Wires with the Right Angle Terminals” on
page 187
“Connecting Bare DC Power Wires” on page 193

Connecting the

DC Power Wires

with the Straight

Terminals

To use the straight terminals to connect the DC power wires to the positive
and negative terminals on the power supply, perform the following
procedure:
1. Prepare adequate lengths of two stranded 8 AWG power wires by
stripping them as shown in Figure 116 on page 179.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation. E10
Straight Terminals Right Angle Terminals

Manual

View the manual for the Allied Telesis AT-SBX81XS6 here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.6. This manual is available in the following languages: English. Do you have a question about the Allied Telesis AT-SBX81XS6 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the Allied Telesis and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

Allied Telesis AT-SBX81XS6 specifications

Below you will find the product specifications and the manual specifications of the Allied Telesis AT-SBX81XS6.

General
BrandAllied Telesis
ModelAT-SBX81XS6 | AT-SBX81XS6
Productnot categorized
EAN0767035195957, 767035195957, 7670351959574
LanguageEnglish
FiletypeUser manual (PDF)
Optical fiber
Fiber optic connectorSFP+
Data transmission
Data transfer rate10 Gbit/s
Ports & interfaces
Fiber ports quantity6
Performance
Compatibilityx8100
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Allied Telesis AT-SBX81XS6 below.

Is the manual of the Allied Telesis AT-SBX81XS6 available in English?

Yes, the manual of the Allied Telesis AT-SBX81XS6 is available in English .

Is your question not listed? Ask your question here

No results