9.3.9.4. ERASE_NON_APPLICATION_ZONE

This command is used to erase the data in Non-Application Zones. The EEPROM memory is
organized into 16-bit words. Although erases are performed on single bit, the ERASE operation clears
an entire word in the memory. Therefore, performing an ERASE on any bit in the word will clear ALL
16 bits of that word to the state of ‘1’.
To erase Error Counter or the data in Application Zones, please refer to the following:
1. ERASE_APPLICATION_ZONE_WITH_ERASE command as specified in Section 9.3.9.5.
2. ERASE_APPLICATION_ZONE_WITH_WRITE_AND_ERASE command as specified in
Section 9.3.9.6.
3. VERIFY_SECURITY_CODE commands as specified in Section 9.3.9.7.
Command Format (abData field in the PC_to_RDR_XfrBlock)
Pseudo-APDU
CLA INS P1 Byte Address MEM_L
FFh D2h 00h 00h
Where:
Byte Address Memory byte address location of the word to be erased
Response Data Format (abData field in the RDR_to_PC_DataBlock)
SW1 SW2
Where:
SW1 SW2 = 90 00h if no error

Manual

View the manual for the ACS ACR38U-N1 here, for free. This manual comes under the category payment terminals and has been rated by 1 people with an average of a 6.7. This manual is available in the following languages: English. Do you have a question about the ACS ACR38U-N1 or do you need help? Ask your question here

Index

Need help?

Do you have a question about the ACS and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 0

ACS ACR38U-N1 specifications

Below you will find the product specifications and the manual specifications of the ACS ACR38U-N1.

General
BrandACS
ModelACR38U-N1 | ACR38U-N1
Productpayment terminal
EAN0190268123662, 0660335876888, 0706551121699, 0707430110490, 0760079617874, 0796389775966, 0798033553890, 4894560168012, 5712505801550, 9010640758576, 6889284468034, 6889284120178
LanguageEnglish
FiletypeUser manual (PDF)
Weight & dimensions
Width20 mm
Height58 mm
Depth13.7 mm
Weight12 g
Design
Product colorBlack
Placement supportedIndoor
LED indicatorsYes
Operational conditions
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)0 - 90 %
Sustainability
Sustainability certificatesRoHS
Ports & interfaces
InterfaceUSB 2.0
show more

Frequently Asked Questions

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the ACS ACR38U-N1 below.

What is the weight of the ACS ACR38U-N1?

The ACS ACR38U-N1 has a weight of 12 g.

What is the height of the ACS ACR38U-N1?

The ACS ACR38U-N1 has a height of 58 mm.

What is the width of the ACS ACR38U-N1?

The ACS ACR38U-N1 has a width of 20 mm.

What is the depth of the ACS ACR38U-N1?

The ACS ACR38U-N1 has a depth of 13.7 mm.

Is the manual of the ACS ACR38U-N1 available in English?

Yes, the manual of the ACS ACR38U-N1 is available in English .

Is your question not listed? Ask your question here

No results