View the manual for the A&D Medical UA-767F here, for free. This manual comes under the category sphygmomanometer and has been rated by 1 people with an average of a 7.5. This manual is available in the following languages: English. Do you have a question about the A&D Medical UA-767F or do you need help? Ask your question here

Need help?

Do you have a question about the A&D Medical and is the answer not in the manual?

  • Receive updates on solutions
  • Get answers to your question

Question and answer

Number of questions: 1
P
Patti ConnorsApril 4, 2024

This almost always happens

1 comment
P
Patti ConnorsApril 4, 2024

@Patti Connors I take my blood pressure, then take it again in about 15 seconds and the top and bottom number are often 6-10 numbers lower then the 1st time...why?

The A&D Medical UA-767F is a sphygmomanometer used for measuring blood pressure. It is a medical device that is designed to provide accurate and reliable readings. The UA-767F sphygmomanometer is equipped with advanced technology that ensures precise measurements. It utilizes an oscillometric method to detect blood pressure, which is known for its accuracy. This makes it a trusted tool for medical professionals and individuals monitoring their blood pressure at home. The device features a large, easy-to-read display that shows systolic and diastolic pressure, as well as pulse rate. It also has a memory function that can store previous readings for up to four users. This allows users to track and monitor their blood pressure over time. The UA-767F sphygmomanometer is designed with user convenience in mind. It has a one-button operation for simplicity and ease of use. The cuff is adjustable and can fit a wide range of arm sizes, providing comfort during the measurement process. This sphygmomanometer is built to last. It is constructed with high-quality materials, ensuring durability and longevity. It is also CE certified and meets the necessary standards to ensure accuracy and safety. In conclusion, the A&D Medical UA-767F is a reliable and accurate sphygmomanometer that provides essential blood pressure measurements. Its user-friendly design and durable construction make it a valuable tool for medical professionals and individuals monitoring their blood pressure.

General
BrandA&D Medical
ModelUA-767F
Productsphygmomanometer
LanguageEnglish
FiletypeUser manual (PDF)

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the A&D Medical UA-767F below.

What does systolic pressure mean?

Systolic pressure is the top number that the blood pressure monitor will indicate. Systolic pressure refers to the amount of pressure in your arteries during the contraction of your heart muscle.

What does diastolilc pressure mean?

Diastolic pressure is the lowest number that the blood pressure monitor will indicate. The bottom number refers to your blood pressure when your heart muscle is between beats.

What is a normal blood pressure?

A normal blood pressure is about 120/80.

How can I prevent explosions when using the device in the presence of flammable gases?

To prevent explosions when using the A&D Medical UA-767F sphygmomanometer in the presence of flammable gases, follow these steps: 1. Do not use the device where flammable gases such as anesthetic gases are present. This is to avoid the risk of an explosion. It is important to note that the manual does not provide further specific steps or precautions regarding the prevention of explosions when using the device in the presence of flammable gases. Therefore, it is recommended to exercise caution and adhere to general safety guidelines when using the sphygmomanometer in any potentially hazardous environment.

What precautions should I take when using the device in highly concentrated oxygen environments?

When using the A&D Medical UA-767F sphygmomanometer in highly concentrated oxygen environments, it is important to take the following precautions: 1. Do not use the device in highly concentrated oxygen environments, such as a high-pressure oxygen chamber or an oxygen tent. This is because the presence of highly concentrated oxygen can increase the risk of fire or explosion. It is crucial to note that the manual does not provide further specific steps or precautions regarding the use of the device in highly concentrated oxygen environments. Therefore, it is recommended to exercise caution and adhere to general safety guidelines when using the sphygmomanometer in any potentially hazardous environment.

How should I dispose of used equipment, parts, and batteries according to local regulations?

When it comes to disposing of used equipment, parts, and batteries of the A&D Medical UA-767F sphygmomanometer according to local regulations, the manual provides the following information: 1. Used equipment, parts, and batteries should not be treated as ordinary household waste. They must be disposed of according to the applicable local regulations. It is important to note that the manual does not provide further specific steps or instructions regarding the disposal process. Therefore, it is recommended to consult the local regulations or contact the appropriate waste management authorities in your area to ensure proper disposal of the used equipment, parts, and batteries. They will be able to provide you with specific guidelines and instructions on how to dispose of these items in an environmentally friendly and safe manner.

What should I do if I experience pain, numbness, or red marks on my arm during blood pressure measurement?

If you experience pain, numbness, or red marks on your arm during blood pressure measurement with the A&D Medical UA-767F sphygmomanometer, follow these steps: 1. Sit comfortably on a chair and rest your arm on a table. Ensure that your legs are not crossed, and your feet are flat on the floor with your back straight. 2. Relax for about five to ten minutes before taking the measurement. 3. Place the center of the cuff at the same height as your heart. 4. Remain still and keep quiet during the measurement. 5. After the measurement, press the START button to turn off the device. 6. Remove the cuff and record your data. 7. It is normal for the cuff to feel very tight during the measurement, so do not be alarmed. 8. Any pain, numbness, or red marks on your arm will disappear with time. It is important to note that these steps are general guidelines provided in the manual. If you continue to experience discomfort or have concerns, it is recommended to consult a healthcare professional for further assistance.

Is it safe to measure blood pressure frequently or can it cause harm due to blood flow interference?

When measuring blood pressure frequently with the A&D Medical UA-767F sphygmomanometer, it is generally safe and does not cause harm due to blood flow interference. However, it is important to follow these guidelines for accurate measurements: 1. Sit comfortably on a chair with your back straight and your arm resting on a table. 2. Relax for about five to ten minutes before taking the measurement. 3. Place the center of the cuff at the same height as your heart. 4. Remain still and keep quiet during the measurement. 5. Avoid measuring right after physical exercise or a bath. Rest for twenty or thirty minutes before taking the measurement. 6. Try to measure your blood pressure at the same time every day for consistent results. It is important to note that frequent blood pressure measurements can provide valuable information about your health. However, if you have any concerns or experience discomfort during measurements, it is recommended to consult a healthcare professional for further guidance.

Is the manual of the A&D Medical UA-767F available in English?

Yes, the manual of the A&D Medical UA-767F is available in English .